Optical Fiber Vibration Sensor With Wide Detection Range Based on STDS Structure Designed by Mach-Zehnder Interferometer

被引:1
|
作者
Liu, Yingfang [1 ]
Wang, Fang [2 ,3 ]
Peng, Yufeng [2 ,3 ]
Yu, Kun [4 ]
Liu, Yufang [4 ]
机构
[1] Henan Normal Univ, Coll Elect & Elect Engn, Xinxiang 453007, Henan, Peoples R China
[2] Henan Normal Univ, Coll Elect & Elect Engn, Xinxiang 453007, Henan, Peoples R China
[3] Henan Normal Univ, Key Lab Optoelect Sensing Integrated Applicat Hen, Xinxiang 453007, Henan, Peoples R China
[4] Henan Normal Univ, Sch Phys, Xinxiang 453007, Henan, Peoples R China
基金
美国国家科学基金会;
关键词
Fast Fourier transform (FFT); frequency response; Mach-Zehnder interferometer; optical fiber sensor; vibration measurement;
D O I
10.1109/JSEN.2023.3321040
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article presents an optical fiber vibration sensor with a wide detection range based on the Mach-Zehnder interference principle, which is composed of single-mode fiber (SMF), two-mode step index fiber (TMSIF), and dispersion-compensated fiber (DCF) fused, and the optical fiber sensing structure fused is SMF-TMSIF-DCF-SMF, abbreviated as STDS sensor. In this work, the single-frequency response and dual-frequency response of this sensor are tested, and the test results indicate that the sensor can stably measure the extended single-frequency response in the range of 1-23 000 Hz (the maximum signal-to-noise ratio (SNR) is 61.2 dB) and the dual-frequency response. In addition, the amplitude-frequency response test results reveal a good linear relationship between the fast Fourier transform (FFT) amplitude and the vibration amplitude. Subsequently, a temperature test was performed on the sensor in the range of 25 degrees C-65 degrees C, and it was found that the spectral intensity shift induced by temperature was only 0.03501 dB/degrees, and the measured frequency was consistent with the applied frequency. Finally, the stability and repeatability tests were carried out on the sensor; the stability test results proved that the sensor measured consistently and without deviations for 60 min, and the repeatability test proved that the sensor could measure consistently for more than 40 days and that the measurement results were accurate. The sensor has the advantages of a wide detection range (the frequency measurement range is 1-23 000 Hz), excellent anti-interference to temperature fluctuations, reusability, and so on, and has great application prospects in various vibration signal monitoring.
引用
收藏
页码:27351 / 27360
页数:10
相关论文
共 50 条
  • [41] Frequency response of distributed fiber-optic vibration sensor based on nonbalanced Mach-Zehnder interferometer
    Wei, Pu
    Shan, Xuekang
    Sun, Xiaohan
    OPTICAL FIBER TECHNOLOGY, 2013, 19 (01) : 47 - 51
  • [42] Temperature Fiber Sensors Based on Mach-Zehnder Interferometer With Sturdy Structure
    Hsu, Jui-Ming
    Zheng, Wen-Hao
    Chen, Jian-Zhi
    Lee, Cheng-Ling
    Horng, Jing-Shyang
    IEEE SENSORS JOURNAL, 2015, 15 (12) : 6995 - 7000
  • [43] Fiber-Optic Twist Sensor Based on a Tapered Fiber Mach-Zehnder Interferometer
    Li, Chai-Ming
    Chan, Chen-Wei
    Horng, Jing-Shyang
    Hsu, Jui-Ming
    Lee, Cheng-Ling
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2013,
  • [44] A Curvature Mach-Zehnder Interferometer Fiber Sensor Based on Triple Cladding and Coreless Fiber
    Zhu, Xiaojun
    Wang, Yan
    Qian, Jiayi
    Liu, Wen
    Li, Shuai
    Cao, Juan
    Zhang, Guoan
    Cai, Yan
    Shi, Yuechun
    Yang, Yongjie
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2024, 36 (15) : 929 - 932
  • [45] Fiber Bragg grating strain sensor based on unbalanced Mach-Zehnder interferometer
    Wang Zhi-guo
    Li Jian-xin
    Zhu Ri-hong
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS IV, 2010, 7853
  • [46] Photonic Crystal Fiber Strain Sensor Based on Modified Mach-Zehnder Interferometer
    Hu, L. M.
    Chan, C. C.
    Dong, X. Y.
    Wang, Y. P.
    Zu, P.
    Wong, W. C.
    Qian, W. W.
    Li, T.
    IEEE PHOTONICS JOURNAL, 2012, 4 (01): : 114 - 118
  • [47] Photonic crystal fiber strain sensor based on cascaded Mach-Zehnder interferometer
    Dong, Xinyong
    Hu, Limin
    Chan, Chi Chiu
    Wang, Yunpeng
    Wong, Wei Chang
    Qian, Wenwen
    Li, Tao
    Zu, Peng
    2011 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND SYSTEMS, 2011, 8201
  • [48] High-Sensitivity Optical Fiber Mach-Zehnder Interferometer Sensor Based on Eight-Core Fiber
    Ji, Yancheng
    Wang, Junjie
    Qian, Jiayi
    Wang, Yan
    Liu, Hai
    Cao, Juan
    Sun, Dan
    Shi, Yuechun
    Yang, Yongjie
    Zhu, Xiaojun
    Wu, Wuming
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2025, 37 (08) : 445 - 448
  • [49] High-sensitivity pressure sensor based on fiber Mach-Zehnder interferometer
    Wu, Yue
    Xu, Yao
    Yang, Yuguang
    Jin, Wenxing
    Jiang, Youchao
    Shen, Ya
    Jian, Shuisheng
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (10)
  • [50] Optical fiber distributed vibration sensor based on dual Mach-Zehnder interferometer using an improved phase generated carrier algorithm
    Sun, Zhenshi
    Xu, Yingzhao
    Yu, Wenxing
    Zhang, Guobin
    Fang, Weiwei
    INFRARED PHYSICS & TECHNOLOGY, 2022, 127