Thermal Safety Boundaries for Laser Power and Irrigation Rate During Ureteroscopy: In Vivo Porcine Assessment With a Ho:YAG Laser

被引:3
|
作者
Marom, Ron [1 ,2 ,3 ,4 ,5 ,6 ]
Dau, Julie J. [1 ,2 ,3 ,4 ,5 ]
Hall, Timothy L. [1 ,2 ,3 ,4 ,5 ]
Ghani, Khurshid R. [1 ,2 ,3 ,4 ,5 ]
Louters, Marne M. [1 ,2 ,3 ,4 ,5 ]
Kim, Hyung Joon [1 ,2 ,3 ,4 ,5 ]
Khajeh, Nikta Rezakahn [1 ,2 ,3 ,4 ,5 ]
Roberts, William W. [1 ,2 ,3 ,4 ,5 ]
机构
[1] Univ Michigan, Dept Urol, Ann Arbor, MI USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI USA
[3] McLaren Macomb, Dept Urol, Mt Clemens, MI USA
[4] Konyang Univ, Dept Urol, Coll Med, Daejeon, South Korea
[5] Beaumont Hlth Syst, Dept Urol, Royal Oak, MI USA
[6] Univ Michigan, Dept Urol, 4432 Med Sci I,1301 Catherine St, Ann Arbor, MI 48109 USA
关键词
TEMPERATURE; LITHOTRIPSY;
D O I
10.1016/j.urology.2023.07.014
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE To map thermal safety boundaries during ureteroscopy (URS) with laser activation in two in vivo porcine subjects to better understand the interplay between laser power, irrigation rate, and fluid temperature in the collecting system. METHODS URS was performed in two in vivo porcine subjects with a prototype ureteroscope containing a thermocouple at its tip. Up to 6 trials of 60 seconds laser activation were carried out at each selected power setting and irrigation rate. Thermal dose was calculated for each trial, and laser power-irrigation rate parameter pairs were categorized based on number of trials that exceeded a thermal dose of 120 equivalent minutes. RESULTS The collecting fluid temperature was increased with greater laser power and slower irrigation rate. In the first porcine subject, 25 W of laser power could safely be applied if irrigation was at least 15 mL/min, and 48 W with at least 30 mL/min. Intermediate values followed a linear curve between these bounds. For the second subject, where the calyx appeared larger, 15 W laser power required 9 mL/min irrigation, 48 W required 24 mL/min, and intermediate points also followed a near-linear curve. CONCLUSION This study validates previous bench research and provides a conceptual framework for selection of safe laser lithotripsy settings and irrigation rates during URS with laser lithotripsy. Additionally, it provides insight and guidance for future development of thermal mitigation strategies and devices. UROLOGY 180: 81-85, 2023. Published by Elsevier Inc.
引用
收藏
页码:81 / 85
页数:5
相关论文
共 43 条
  • [1] IN-VIVO THERMAL SAFETY VALIDATION OF URETEROSCOPY LASER POWER - IRRIGATION RATE PARAMETER PAIRS
    Marom, Ron
    Dau, Julie J.
    Ghani, Khurshid R.
    Hall, Timothy L.
    Roberts, William W.
    JOURNAL OF UROLOGY, 2023, 209 : E960 - E960
  • [2] IS THE THULIUM FIBER LASER SUPERIOR TO THE LOW-POWER HO:YAG LASER FOR URETEROSCOPY IN CHILDREN?
    Jaeger, Christopher
    Nelson, Caleb
    Cilento, Bartley
    Logvinenko, Tanya
    Kurtz, Michael
    JOURNAL OF UROLOGY, 2022, 207 (05): : E799 - E799
  • [3] Do Stone Characteristics and Laser Fiber Size Affect Ho: YAG Laser Time and Energy During Ureteroscopy?
    Hilowle, Abdihamid Hassan
    Mohamed, Abdikarim Hussein
    RESEARCH AND REPORTS IN UROLOGY, 2024, 16 : 115 - 121
  • [4] Thermal effects of Ho:YAG laser lithotripsy during retrograde intrarenal surgery and percutaneous nephrolithotomy in an ex vivo porcine kidney model
    Hein, Simon
    Petzold, Ralf
    Suarez-Ibarrola, Rodrigo
    Mueller, Philippe-Fabian
    Schoenthaler, Martin
    Miernik, Arkadiusz
    WORLD JOURNAL OF UROLOGY, 2020, 38 (03) : 753 - 760
  • [5] Thermal effects of Ho:YAG laser lithotripsy during retrograde intrarenal surgery and percutaneous nephrolithotomy in an ex vivo porcine kidney model
    Simon Hein
    Ralf Petzold
    Rodrigo Suarez-Ibarrola
    Philippe-Fabian Müller
    Martin Schoenthaler
    Arkadiusz Miernik
    World Journal of Urology, 2020, 38 : 753 - 760
  • [6] Image Distortion During Flexible Ureteroscopy: A Laboratory Model Comparing Super Pulsed Thulium Fiber Laser vs High-Power Ho:YAG Laser
    Miller, Caleb S.
    Whiles, Bristol B.
    Ito, Willian E.
    Machen, Edward
    Thompson, Jeffrey A.
    Duchene, David A.
    Neff, Donald A.
    Molina, Wilson R.
    JOURNAL OF ENDOUROLOGY, 2023, 37 (01) : 99 - 104
  • [7] IMAGE DISTORTION DURING FLEXIBLE URETEROSCOPY: A LABORATORY MODEL COMPARING SUPER PULSE THULIUM FIBER (SPTF) LASER VS HIGH POWER HO:YAG LASER
    Miller, Caleb S.
    Whiles, Bristol B.
    Duchene, David A.
    Neff, Donald A.
    Molina, Wilson R.
    JOURNAL OF UROLOGY, 2021, 206 : E440 - E440
  • [8] Temperature profiles of calyceal irrigation fluids during flexible ureteroscopic Ho:YAG laser lithotripsy
    Teng, Jingfei
    Wang, Yi
    Jia, Zhuomin
    Guan, Yawei
    Fei, Weiwei
    Ai, Xing
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2021, 53 (03) : 415 - 419
  • [9] Temperature profiles of calyceal irrigation fluids during flexible ureteroscopic Ho:YAG laser lithotripsy
    Jingfei Teng
    Yi Wang
    Zhuomin Jia
    Yawei Guan
    Weiwei Fei
    Xing Ai
    International Urology and Nephrology, 2021, 53 : 415 - 419
  • [10] Renal temperatures and thermal profiles during ureteroscopy with Thulium Fiber Laser and Holmium YAG laser: Findings from a preclinical study
    Asoy, M. S.
    Juliebo-Jones, P.
    Beisland, C.
    Ulvik, O.
    EUROPEAN UROLOGY, 2022, 81 : S1739 - S1740