Performance of a triple GEM detector equipped with Al-GEM foils for X-rays detection

被引:7
|
作者
Caruggi, Federico [1 ,2 ]
Cancelli, Stephanie [1 ,3 ]
Celora, Agostino [1 ]
Guiotto, Federico [1 ]
Croci, Gabriele [1 ,2 ,3 ]
Tardocchi, Marco [2 ,3 ]
Murtas, Fabrizio [4 ]
de Oliveira, Rui [5 ]
Cippo, Enrico Perelli [2 ]
Gorini, Giuseppe [1 ,2 ,3 ]
Grosso, Giovanni [2 ]
Muraro, Andrea [2 ]
机构
[1] Univ Milano Bicocca, Dipartimento Fis G Occhialini, Piazza Sci 3, I-20125 Milan, Italy
[2] CNR, Ist Sci & Tecnol Plasmi, Via Cozzi 53, I-20125 Milan, Italy
[3] Ist Nazl Fis Nucl, Sez Milano Bicocca, Piazza Sci 3, I-20125 Milan, Italy
[4] Ist Nazl Fis Nucl, Lab Nazl Frascati, Via Enr Fermi 40, I-00044 Frascati, Italy
[5] European Org Nucl Res CERN, Geneva, Switzerland
关键词
Micropattern Gaseous detectors; Gas electron multiplier; X-ray detectors; SYSTEM;
D O I
10.1016/j.nima.2022.167855
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The study of Soft X-ray emission can be a source of fundamental information, particularly for what concerns tokamaks and plasma diagnostics, but also in general in the fields of high energy and nuclear physics. Detection systems based on Gas Electron Multipliers (GEM) technology can be of particular use in the context of X-ray analyses, being relatively low cost while maintaining good spatial and temporal resolution and capability to sustain high counting rates (up to MHz/mm2). The development of these new and improved detectors is thus of interest, especially in the research about diagnostic and control of machines for fusion energy. In this work, the performance of a new triple-GEM detector, characterized by an aluminum metallic coating on both layers of the GEM foils, is presented and a comparison is made with the more conventional design employing copper coating. The performances of an aluminum-coated GEM (Al-GEM) detector and of a standard copper-coated GEM (Cu-GEM) detector in revealing quasi-monochromatic X-ray beams coming from different fluorescence materials are compared. The Al-GEM detector is shown to less suffer the issue of unwanted background on the signal caused by the presence of copper inside the detector itself. The suppression of this noise source encourages the use of Al-GEM detectors to perform spectroscopy in harsh environments, such as tokamak machines, where soft X-rays are useful probes to control different plasma properties and parameters.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] SEMICONDUCTOR DETECTOR PERFORMANCE FOR LOW-ENERGY X-RAYS
    JAKLEVIC, JM
    WALTON, JT
    MCMURRAY, RE
    MADDEN, NW
    GOULDING, FS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3): : 598 - 601
  • [22] STUDY ON TEMPERATURE COEFFICIENT OF CdTe DETECTOR USED FOR X-RAYS DETECTION
    Guo, Siming
    Wu, Jinjie
    Du, Haiyan
    Zhang, Jian
    Li, Xufang
    Liu, Congzhan
    Zhang, Shuai
    Li, Chengze
    Huo, Binbin
    Liao, Zhenyu
    Liu, Ying
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2017, 32 (03): : 256 - 260
  • [23] Performance of a triple-GEM detector with capacitive-sharing 3-coordinate (X-Y-U)-strip anode readout
    Gnanvo, Kondo
    Lee, Seung Joon
    Mehl, Bertrand
    de Oliveira, Rui
    Weisenberger, Andrew
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1066
  • [24] Effect of charging-up and regular usage on performance of the triple GEM detector to be employed for plasma radiation monitoring
    Chernyshova, Maryna
    Malinowski, Karol
    Czarski, Tomasz
    Demchenko, Iraida N.
    Melikhov, Yevgen
    Kowalska-Strzeciwilk, Ewa
    Wojenski, Andrzej
    Krawczyk, Rafal D.
    FUSION ENGINEERING AND DESIGN, 2020, 158
  • [25] Novel triple-GEM mechanical design for the CMS-ME0 detector and its preliminary performance
    Fallavollita, F.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (08)
  • [26] STELLAR CORONAE, SOLAR FLARES: A DETAILED COMPARISON OF σ GEM, HR 1099, AND THE SUN IN HIGH-RESOLUTION X-RAYS
    Huenemoerder, David P.
    Phillips, Kenneth J. H.
    Sylwester, Janusz
    Sylwester, Barbara
    ASTROPHYSICAL JOURNAL, 2013, 768 (02):
  • [27] DETECTION OF PROTON-INDUCED BORON X-RAYS WITH A SI(LI) DETECTOR
    MUSKET, RG
    NUCLEAR INSTRUMENTS & METHODS, 1974, 117 (02): : 385 - 389
  • [28] Study on the novel neutron-to-proton convertor for improving the detection efficiency of a triple GEM based fast neutron detector
    Wang Xiao-Dong
    Yang He-Run
    Ren Zhong-Guo
    Zhang Jun-Wei
    Yang Lei
    Zhang Chun-Hui
    Ha Ri-Ba-La
    An Lu-Xing
    Hu Bi-Tao
    CHINESE PHYSICS C, 2015, 39 (02) : 45 - 49
  • [29] Study on the novel neutron-to-proton convertor for improving the detection efficiency of a triple GEM based fast neutron detector
    王晓冬
    杨贺润
    任忠国
    张俊伟
    杨磊
    张春晖
    哈日巴拉
    安旅行
    胡碧涛
    Chinese Physics C, 2015, (02) : 45 - 49
  • [30] Study on the novel neutron-to-proton convertor for improving the detection efficiency of a triple GEM based fast neutron detector
    王晓冬
    杨贺润
    任忠国
    张俊伟
    杨磊
    张春晖
    哈日巴拉
    安旅行
    胡碧涛
    Chinese Physics C, 2015, 39 (02) : 45 - 49