Radiopaque Nanorobots as Magnetically Navigable Contrast Agents for Localized In Vivo Imaging of the Gastrointestinal Tract

被引:19
|
作者
Oral, Cagatay M. M. [1 ]
Ussia, Martina [1 ]
Urso, Mario [1 ]
Salat, Jiri [2 ,3 ]
Novobilsky, Adam [4 ]
Stefanik, Michal [2 ,5 ]
Ruzek, Daniel [2 ,3 ,6 ]
Pumera, Martin [1 ,7 ,8 ,9 ]
机构
[1] Brno Univ Technol, Cent European Inst Technol, Future Energy & Innovat Lab, Purkynova 123, CZ-61200 Brno, Czech Republic
[2] Vet Res Inst, Lab Emerging Viral Infect, Hudcova 296-70, CZ-62100 Brno, Czech Republic
[3] Czech Acad Sci, Inst Parasitol, Biol Ctr, Branisovska 31, CZ-37005 Ceske Budejovice, Czech Republic
[4] Vet Res Inst, Dept Pharmacol & Toxicol, Hudcova 296-70, CZ-62100 Brno, Czech Republic
[5] Mendel Univ Brno, Dept Chem & Biochem, Zemedelska 1665-1, CZ-61300 Brno, Czech Republic
[6] Masaryk Univ, Fac Sci, Dept Expt Biol, Kamenice 735-5, CZ-62500 Brno, Czech Republic
[7] China Med Univ, China Med Univ Hosp, Dept Med Res, 91 Hsueh Shih Rd, Taichung 40402, Taiwan
[8] VSB Tech Univ Ostrava, Fac Elect Engn & Comp Sci, 17 Listopadu 2172-15, CZ-70800 Ostrava, Czech Republic
[9] Yonsei Univ, Dept Chem & Biomol Engn, 50 Yonsei Ro, Seoul 03722, South Korea
关键词
computed tomography; gastrointestinal tract; magnetic actuation; medical imaging; nanomotors; nanoswimmers; tracking; NANOPARTICLES;
D O I
10.1002/adhm.202202682
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic nanorobots offer wireless navigation capability in hard-to-reach areas of the human body for targeted therapy and diagnosis. Though in vivo imaging is required for guidance of the magnetic nanorobots toward the target areas, most of the imaging techniques are inadequate to reveal the potential locomotion routes. This work proposes the use of radiopaque magnetic nanorobots along with microcomputed tomography (microCT) for localized in vivo imaging applications. The nanorobots consist of a contrast agent, barium sulfate (BaSO4), magnetized by the decoration of magnetite (Fe3O4) particles. The magnetic features lead to actuation under rotating magnetic fields and enable precise navigation in a microfluidic channel used to simulate confined spaces of the body. In this channel, the intrinsic radiopacity of the nanorobots also provides the possibility to reveal the internal structures by X-ray contrast. Furthermore, in vitro analysis indicates nontoxicity of the nanorobots. In vivo experiments demonstrate localization of the nanorobots in a specific part of the gastrointestinal (GI) tract upon the influence of the magnetic field, indicating the efficient control even in the presence of natural peristaltic movements. The nanorobots reported here highlight that smart nanorobotic contrast agents can improve the current imaging-based diagnosis techniques by providing untethered controllability in vivo.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Research progress of contrast agents for bacterial infection imaging in vivo
    Zhang, Yaqing
    Hao, Mengqi
    Li, Linyao
    Luo, Qin
    Deng, Siyu
    Yang, Yun
    Liu, Yan
    Fang, Weiwei
    Song, Erqun
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2023, 159
  • [22] Phthalocyanine photosensitizers as contrast agents for in vivo photoacoustic tumor imaging
    Attia, Amalina Bte Ebrahim
    Balasundaram, Ghayathri
    Driessen, Wouter
    Ntziachristos, Vasilis
    Olivo, Malini
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (02): : 591 - 598
  • [23] Silver Nanoplate Contrast Agents for in Vivo Molecular Photoacoustic Imaging
    Homan, Kimberly A.
    Souza, Michael
    Truby, Ryan
    Luke, Geoffrey P.
    Green, Christopher
    Vreeland, Erika
    Emelianov, Stanislav
    ACS NANO, 2012, 6 (01) : 641 - 650
  • [24] Engineering Contrast Agents for Gastrointestinal Magnetic Particle Imaging: The Biological Perspective
    Ramaker, Katrin
    Roeckendorf, Niels
    Frey, Andreas
    MAGNETIC PARTICLE IMAGING: A NOVEL SPIO NANOPARTICLE IMAGING TECHNIQUE, 1ST EDITION, 2012, 140 : 205 - 210
  • [25] Use of Magnetic Resonance Imaging Contrast Agents in the Liver and Biliary Tract
    LeBedis, Christina
    Luna, Antonio
    Soto, Jorge A.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2012, 20 (04) : 715 - +
  • [26] Synchrotron- and laboratory-based X-ray phase-contrast imaging for imaging mouse articular cartilage in the absence of radiopaque contrast agents
    Marenzana, Massimo
    Hagen, Charlotte K.
    Borges, Patricia Das Neves
    Endrizzi, Marco
    Szafraniec, Magdalena B.
    Vincent, Tonia L.
    Rigon, Luigi
    Arfelli, Fulvia
    Menk, Ralf-Hendrik
    Olivo, Alessandro
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2014, 372 (2010):
  • [27] Ex-vivo MR imaging of liver intracellular contrast agents
    Mascalchi, M
    Jin, XN
    Agen, C
    Petruzzi, P
    Nardini, D
    Tessa, C
    Caramella, D
    Bartolozzi, C
    MAGNETIC RESONANCE IMAGING, 1997, 15 (04) : 469 - 474
  • [28] Differential structured illumination microendoscopy for in vivo imaging of molecular contrast agents
    Keahey, Pelham
    Ramalingam, Preetha
    Schmeler, Kathleen
    Richards-Kortum, Rebecca R.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2016, 113 (39) : 10769 - 10773
  • [29] Development and Screening of Contrast Agents for In Vivo Imaging of Parkinson's Disease
    Neal, Krista L.
    Shakerdge, Naomi B.
    Hou, Steven S.
    Klunk, William E.
    Mathis, Chester A.
    Nesterov, Evgueni E.
    Swager, Timothy M.
    McLean, Pamela J.
    Bacskai, Brian J.
    MOLECULAR IMAGING AND BIOLOGY, 2013, 15 (05) : 585 - 595
  • [30] Development and Screening of Contrast Agents for In Vivo Imaging of Parkinson’s Disease
    Krista L. Neal
    Naomi B. Shakerdge
    Steven S. Hou
    William E. Klunk
    Chester A. Mathis
    Evgueni E. Nesterov
    Timothy M. Swager
    Pamela J. McLean
    Brian J. Bacskai
    Molecular Imaging and Biology, 2013, 15 : 585 - 595