Unsupervised physiological noise correction of functional magnetic resonance imaging data using phase and magnitude information (PREPAIR)

被引:3
|
作者
Bancelin, David [1 ]
Bachrata, Beata [1 ,2 ]
Bollmann, Saskia [3 ]
Cardoso, Pedro de Lima [1 ]
Szomolanyi, Pavol [1 ]
Trattnig, Siegfried [1 ,2 ]
Robinson, Simon Daniel [1 ,2 ,3 ,4 ,5 ]
机构
[1] Med Univ Vienna, High Field MR Ctr, Dept Biomed Imaging & Image Guided Therapy, Vienna, Austria
[2] Karl Landsteiner Inst Clin Mol MR Musculoskeletal, Vienna, Austria
[3] Univ Queensland, Ctr Adv Imaging, Brisbane, Australia
[4] Med Univ Graz, Dept Neurol, Graz, Austria
[5] Med Univ Vienna, High Field MR Ctr, Lazarettgasse14, A-1090 Vienna, Austria
基金
奥地利科学基金会;
关键词
PREPAIR; fMRI; phase data; physiological noise; noise correction; unsupervised; INDEPENDENT COMPONENT ANALYSIS; BRAIN-STEM; HEART-RATE; FMRI; BOLD; FLUCTUATIONS; SIGNAL; ARTIFACTS; MRI; IDENTIFICATION;
D O I
10.1002/hbm.26152
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Of the sources of noise affecting blood oxygen level-dependent functional magnetic resonance imaging (fMRI), respiration and cardiac fluctuations are responsible for the largest part of the variance, particularly at high and ultrahigh field. Existing approaches to removing physiological noise either use external recordings, which can be unwieldy and unreliable, or attempt to identify physiological noise from the magnitude fMRI data. Data-driven approaches are limited by sensitivity, temporal aliasing, and the need for user interaction. In the light of the sensitivity of the phase of the MR signal to local changes in the field stemming from physiological processes, we have developed an unsupervised physiological noise correction method using the information carried in the phase and the magnitude of echo-planar imaging data. Our technique, Physiological Regressor Estimation from Phase and mAgnItude, sub-tR (PREPAIR) derives time series signals sampled at the slice TR from both phase and magnitude images. It allows physiological noise to be captured without aliasing, and efficiently removes other sources of signal fluctuations not related to physiology, prior to regressor estimation. We demonstrate that the physiological signal time courses identified with PREPAIR agree well with those from external devices and retrieve challenging cardiac dynamics. The removal of physiological noise was as effective as that achieved with the most used approach based on external recordings, RETROICOR. In comparison with widely used recording-free physiological noise correction tools-PESTICA and FIX, both performed in unsupervised mode-PREPAIR removed significantly more respiratory and cardiac noise than PESTICA, and achieved a larger increase in temporal signal-to-noise-ratio at both 3 and 7 T.
引用
收藏
页码:1209 / 1226
页数:18
相关论文
共 50 条
  • [21] The utility of near-infrared spectroscopy in the regression of low-frequency physiological noise from functional magnetic resonance imaging data
    Cooper, R. J.
    Gagnon, Louis
    Goldenholz, Daniel M.
    Boas, David A.
    Greve, Douglas N.
    NEUROIMAGE, 2012, 59 (04) : 3128 - 3138
  • [22] Effect of Physiological Noise on Thoracolumbar Spinal Cord Functional Magnetic Resonance Imaging in 3T Magnetic Field
    Dehghani, Hamed
    Oghabian, Mohammad Ali
    Batouli, Seyed Amir Hosein
    Kheradmand, Jalil Arab
    Khatibi, Ali
    BASIC AND CLINICAL NEUROSCIENCE, 2020, 11 (06) : 737 - 751
  • [23] CORRECTION OF PHASE WRAPPING IN MAGNETIC-RESONANCE IMAGING
    AXEL, L
    MORTON, D
    MEDICAL PHYSICS, 1989, 16 (02) : 284 - 287
  • [24] Physiological Considerations of Functional Magnetic Resonance Imaging in Animal Models
    Sumiyoshi, Akira
    Keeley, Robin J.
    Lu, Hanbing
    BIOLOGICAL PSYCHIATRY-COGNITIVE NEUROSCIENCE AND NEUROIMAGING, 2019, 4 (06) : 522 - 532
  • [25] Modeling and suppression of respiration-related physiological noise in echo-planar functional magnetic resonance imaging using global and one-dimensional navigator echo correction
    Barry, RL
    Menon, RS
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) : 411 - 418
  • [26] Noise suppression digital filter for functional magnetic resonance imaging based on image reference data
    Buonocore, MH
    Maddock, RJ
    MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) : 456 - 469
  • [27] A method to analyze low signal-to-noise ratio functional magnetic resonance imaging data
    Zhu, Xi
    Kayali, M. Amin
    Jansen, Ben H.
    JOURNAL OF INTEGRATIVE NEUROSCIENCE, 2015, 14 (03) : 325 - 342
  • [28] Functional magnetic resonance imaging using RASER
    Goerke, Ute
    Garwood, Michael
    Ugurbil, Kamil
    NEUROIMAGE, 2011, 54 (01) : 350 - 360
  • [29] Big Data Application in Functional Magnetic Resonance Imaging using Apache Spark
    Sarraf, Saman
    Ostadhashem, Mehdi
    PROCEEDINGS OF 2016 FUTURE TECHNOLOGIES CONFERENCE (FTC), 2016, : 281 - 284
  • [30] Retrospective coregistration of functional magnetic resonance imaging data using external monitoring
    Tremblay, M
    Tam, F
    Graham, SJ
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (01) : 141 - 149