SwinUNet: a multiscale feature learning approach to cardiovascular magnetic resonance parametric mapping for myocardial tissue characterization

被引:0
|
作者
Qi, Yifan [1 ]
Wang, Fusheng [1 ]
Kong, Jun [2 ]
Cao, J. Jane [3 ,4 ]
Li, Yu Y. [3 ,5 ]
机构
[1] SUNY Stony Brook, Dept Comp Sci, Stony Brook, NY 11790 USA
[2] Georgia State Univ, Dept Math & Stat, Atlanta, GA 30303 USA
[3] USA, Blountstown, FL 11576 USA
[4] SUNY Stony Brook, Clin Med, Stony Brook, NY 11790 USA
[5] SUNY Stony Brook, Dept Biomed Engn, Stony Brook, NY 11790 USA
关键词
cardiovascular magnetic resonance; parametric mapping; multiscale feature learning; HEART;
D O I
10.1088/1361-6579/ad2c15
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective. Cardiovascular magnetic resonance (CMR) can measure T1 and T2 relaxation times for myocardial tissue characterization. However, the CMR procedure for T1/T2 parametric mapping is time-consuming, making it challenging to scan heart patients routinely in clinical practice. This study aims to accelerate CMR parametric mapping with deep learning. Approach. A deep-learning model, SwinUNet, was developed to accelerate T1/T2 mapping. SwinUNet used a convolutional UNet and a Swin transformer to form a hierarchical 3D computation structure, allowing for analyzing CMR images spatially and temporally with multiscale feature learning. A comparative study was conducted between SwinUNet and an existing deep-learning model, MyoMapNet, which only used temporal analysis for parametric mapping. The T1/T2 mapping performance was evaluated globally using mean absolute error (MAE) and structural similarity index measure (SSIM). The clinical T1/T2 indices for characterizing the left-ventricle myocardial walls were also calculated and evaluated using correlation and Bland-Altman analysis. Main results. We performed accelerated T1 mapping with <= 4 heartbeats and T2 mapping with 2 heartbeats in reference to the clinical standard, which required 11 heartbeats for T1 mapping and 3 heartbeats for T2 mapping. SwinUNet performed well in all the experiments (MAE < 50 ms, SSIM > 0.8, correlation > 0.75, and Bland-Altman agreement limits < 100 ms for T1 mapping; MAE < 1 ms, SSIM > 0.9, correlation > 0.95, and Bland-Altman agreement limits < 1.5 ms for T2 mapping). When the maximal acceleration was used (2 heartbeats), SwinUNet outperformed MyoMapNet and gave measurement accuracy similar to the clinical standard. Significance. SwinUNet offers an optimal solution to CMR parametric mapping for assessing myocardial diseases quantitatively in clinical cardiology.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Parametric mapping by cardiovascular magnetic resonance imaging in sudden cardiac arrest survivors
    Katarzyna E. Gil
    Vien T. Truong
    Karolina M. Zareba
    Juliet Varghese
    Orlando P. Simonetti
    Saurabh Rajpal
    The International Journal of Cardiovascular Imaging, 2023, 39 : 1547 - 1555
  • [32] SERIAL CARDIOVASCULAR MAGNETIC RESONANCE WITH PARAMETRIC MAPPING DURING TREATMENT FOR TRANSPLANT REJECTION
    Sharif, Marina
    Tushak, Zackary
    Rudisill, Kristyn
    Tchoukina, Inna
    Trankle, Cory
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 2699 - 2699
  • [33] Cardiovascular Magnetic Resonance Parametric Mapping Techniques for the Assessment of Chronic Coronary Syndromes
    Bazmpani, Maria Anna
    Nikolaidou, Chrysovalantou
    Papanastasiou, Christos A.
    Ziakas, Antonios
    Karamitsos, Theodoros D.
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2022, 9 (12)
  • [34] Importance of parametric mapping and deconvolution in analyzing magnetic resonance myocardial perfusion images
    Carme, S
    Maï, W
    Mazzadi, A
    Janier, M
    Revel, D
    Magnin, I
    Wiart, M
    Neyran, B
    Canet-Soulas, E
    INVESTIGATIVE RADIOLOGY, 2006, 41 (04) : 374 - 383
  • [35] Tissue characterization by T1 and T2 mapping cardiovascular magnetic resonance imaging to monitor myocardial inflammation in healing myocarditis
    Bohnen, S.
    Radunski, U. K.
    Lund, G. K.
    Ojeda, F.
    Looft, Y.
    Senel, M.
    Radziwolek, L.
    Avanesov, M.
    Tahir, E.
    Stehning, C.
    Schnackenburg, B.
    Adam, G.
    Blankenberg, S.
    Muellerleile, K.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2017, 18 (07) : 744 - 751
  • [36] T1 mapping: non-invasive evaluation of myocardial tissue composition by cardiovascular magnetic resonance
    Bhuva, Anish N.
    Treibel, Thomas A.
    Fontana, Marianna
    Herrey, Anna S.
    Manisty, Charlotte H.
    Moon, James C.
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2014, 12 (12) : 1455 - 1464
  • [37] Asymptomatic Cocaine Abuse - Myocardial Tissue Characterization Using Cardiac Biomarkers and Cardiovascular Magnetic Resonance Imaging -
    Radunski, Ulf K.
    Fuger, Ulrike
    Bohnen, Sebastian
    Lund, Gunnar K.
    Stehning, Christian
    Zeller, Tanja
    Tahir, Enver
    Avanesov, Maxim
    Adam, Gerhard
    Blankenberg, Stefan
    Reimer, Jens
    Muellerleile, Kai
    CIRCULATION JOURNAL, 2017, 81 (05) : 701 - 708
  • [38] Additional value of cardiac magnetic resonance parametric mapping in tissue characterization of common benign paediatric cardiac tumours
    Ciliberti, Paolo
    Bordonaro, Veronica
    Curione, Davide
    Perazzolo, Alessio
    Ciancarella, Paolo
    Santangelo, Teresa
    Napolitano, Carmela
    Natale, Luigi
    Galletti, Lorenzo
    Secinaro, Aurelio
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 26 (01) : 161 - 168
  • [39] Inter-study reproducibility of cardiovascular magnetic resonance myocardial feature tracking
    Geraint Morton
    Andreas Schuster
    Roy Jogiya
    Shelby Kutty
    Philipp Beerbaum
    Eike Nagel
    Journal of Cardiovascular Magnetic Resonance, 14
  • [40] Inter-study reproducibility of cardiovascular magnetic resonance myocardial feature tracking
    Morton, Geraint
    Schuster, Andreas
    Jogiya, Roy
    Kutty, Shelby
    Beerbaum, Philipp
    Nagel, Eike
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14