Evaluation of Trabecular Microstructure of Cancellous Bone Using Quarter-Detector Computed Tomography

被引:1
|
作者
Hasegawa, Hiroaki [1 ]
Nango, Nobuhito [2 ]
Machida, Masafumi [3 ]
机构
[1] Int Univ Hlth & Welf, Dept Radiol Sci, Narita 2868686, Japan
[2] Ratoc Syst Engn Co Ltd, Tokyo 1620801, Japan
[3] Hakujikai Mem Hosp, Dept Orthoped Surg, Tokyo 1230864, Japan
关键词
osteoporosis; quarter-detector computed tomography; micro-computed tomography; trabecular microstructure; cancellous bone; HIGH-RESOLUTION CT; MINERAL DENSITY; MICROARCHITECTURE; THICKNESS; WOMEN; QUANTIFICATION; PREMENOPAUSAL; MONOTHERAPY; MECHANISMS; PATTERN;
D O I
10.3390/diagnostics13071240
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Quarter-detector computed tomography (QDCT) is an ultra-high-spatial-resolution imaging technique. This study aimed to verify the validity of trabecular structure evaluation using a QDCT scanner in the diagnosis of osteoporosis. We used a cancellous bone specimen image of the second lumbar vertebrae of an adult male with moderate osteoporosis. To obtain QDCT images, we created a three-dimensional model from micro-CT images of the specimen. Statistical analysis was performed on the relationship between micro-CT and QDCT imaging modalities. The differences between micro-CT and QDCT were assessed based on their significance with respect to the calculated mean measurements using the Mann-Whitney test. Single regression analysis was performed using linear regression, with micro-CT and QDCT as the explanatory and objective variables, respectively, to determine the relationship of the measured values between the two modalities. By applying the necessary correction to the micro-CT measured values, it is possible to perform an analysis equivalent to micro-CT, which offers higher spatial resolution than QDCT. We found evidence that if QDCT can be used, trabecular structure evaluation may contribute to image diagnosis to evaluate practical bone fragility.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Numerical Analysis of Variability in Ultrasound Propagation Properties Induced by Trabecular Microstructure in Cancellous Bone
    Hosokawa, Atsushi
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (04) : 738 - 747
  • [42] Assessment of the Trabecular Bone Microstructure Surrounding Impacted Maxillary Canines Using Fractal Analysis on Cone-Beam Computed Tomography Images
    Sunal Akturk, Ezgi
    Toktas, Ahsen Irem
    Can, Erkay
    Kosen, Ezgi
    Sarica, Irfan
    DIAGNOSTICS, 2024, 14 (19)
  • [43] The effect of voxel size on high-resolution peripheral computed tomography measurements of trabecular and cortical bone microstructure
    Tjong, Willy
    Kazakia, Galateia J.
    Burghardt, Andrew J.
    Majumdar, Sharmila
    MEDICAL PHYSICS, 2012, 39 (04) : 1893 - 1903
  • [44] Assessement of trabecular microstructure using ultrasonic statistical models of trabecular bone microstructure.
    Jenson, F
    Padilla, F
    Laugier, P
    JOURNAL OF BONE AND MINERAL RESEARCH, 2002, 17 : S420 - S420
  • [45] Estimation of trabecular bone axis for characterization of cancellous bone using scattered ultrasonic wave
    Kitamura, K
    Nishikouri, H
    Ueha, S
    Kimura, S
    Ohtomo, N
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1998, 37 (5B): : 3082 - 3087
  • [46] Assessment of trabecular bone texture in the distal radius using peripheral quantitative computed tomography (pQCT)
    MacArtain, AM
    Webber, CE
    Inglis, D
    Gordon, CL
    OSTEOPOROSIS INTERNATIONAL, 2004, 15 : S30 - S31
  • [47] Trabecular Bone Morphological Analysis for Preclinical Osteoporosis Application Using Micro Computed Tomography Scanner
    David Shih-Chun Jin
    Chien-Hao Chu
    Jyh-Cheng Chen
    Journal of Medical and Biological Engineering, 2016, 36 : 96 - 104
  • [48] Morphometric Analysis of Mandibular Trabecular Bone Using Cone Beam Computed Tomography: An In Vitro Study
    Naitoh, Munetaka
    Aimiya, Hidetoshi
    Hirukawa, Akiko
    Ariji, Eiichiro
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (06) : 1093 - 1098
  • [49] Trabecular Bone Morphological Analysis for Preclinical Osteoporosis Application Using Micro Computed Tomography Scanner
    Jin, David Shih-Chun
    Chu, Chien-Hao
    Chen, Jyh-Cheng
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2016, 36 (01) : 96 - 104
  • [50] Evaluation of cortical bone by computed tomography
    Hangartner, TN
    Gilsanz, V
    JOURNAL OF BONE AND MINERAL RESEARCH, 1996, 11 (10) : 1518 - 1525