Machine Learning for Detecting Total Knee Arthroplasty Implant Loosening on Plain Radiographs

被引:7
|
作者
Kim, Man-Soo [1 ]
Cho, Ryu-Kyoung [1 ]
Yang, Sung-Cheol [1 ]
Hur, Jae-Hyeong [1 ]
In, Yong [1 ]
机构
[1] Catholic Univ Korea, Seoul St Marys Hosp, Coll Med, Dept Orthopaed Surg, 222 Banpo Daero, Seoul 06591, South Korea
来源
BIOENGINEERING-BASEL | 2023年 / 10卷 / 06期
基金
新加坡国家研究基金会;
关键词
loosening; total knee arthroplasty; radiograph; machine learning; convolutional neural network; transfer learning;
D O I
10.3390/bioengineering10060632
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
(1) Background: The purpose of this study was to investigate whether the loosening of total knee arthroplasty (TKA) implants could be detected accurately on plain radiographs using a deep convolution neural network (CNN). (2) Methods: We analyzed data for 100 patients who underwent revision TKA due to prosthetic loosening at a single institution from 2012 to 2020. We extracted 100 patients who underwent primary TKA without loosening through a propensity score, matching for age, gender, body mass index, operation side, and American Society of Anesthesiologists class. Transfer learning was used to prepare a detection model using a pre-trained Visual Geometry Group (VGG) 19. For transfer learning, two methods were used. First, the fully connected layer was removed, and a new fully connected layer was added to construct a new model. The convolutional layer was frozen without training, and only the fully connected layer was trained (transfer learning model 1). Second, a new model was constructed by adding a fully connected layer and varying the range of freezing for the convolutional layer (transfer learning model 2). (3) Results: The transfer learning model 1 gradually increased in accuracy and ultimately reached 87.5%. After processing through the confusion matrix, the sensitivity was 90% and the specificity was 100%. Transfer learning model 2, which was trained on the convolutional layer, gradually increased in accuracy and ultimately reached 97.5%, which represented a better improvement than for model 1. Processing through the confusion matrix affirmed that the sensitivity was 100% and the specificity was 97.5%. (4) Conclusions: The CNN algorithm, through transfer learning, shows high accuracy for detecting the loosening of TKA implants on plain radiographs.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Implant selection in revision total knee arthroplasty
    Nelson, CL
    Gioe, TJ
    Cheng, EY
    Thompson, RC
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A : 43 - 51
  • [22] Fluoroscopically Assisted Radiographs Improve Sensitivity of Detecting Loose Tibial Implants in Revision Total Knee Arthroplasty
    Chalmers, Brian P.
    Sculco, Peter K.
    Fehring, Keith A.
    Taunton, Michael J.
    Trousdale, Robert T.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (02): : 570 - 574
  • [23] Surgical Outcome Prediction in Total Knee Arthroplasty using Machine Learning
    Hossain, Belayat
    Morooka, Takatoshi
    Okuno, Makiko
    Nii, Manabu
    Yoshiya, Shinichi
    Kobashi, Syoji
    INTELLIGENT AUTOMATION AND SOFT COMPUTING, 2019, 25 (01): : 105 - 115
  • [24] Predicting total knee arthroplasty from ultrasonography using machine learning
    Tiulpin, Aleksei
    Saarakkala, Simo
    Mathiessen, Alexander
    Hammer, Hilde Berner
    Furnes, Ove
    Nordsletten, Lars
    Englund, Martin
    Magnusson, Karin
    OSTEOARTHRITIS AND CARTILAGE OPEN, 2022, 4 (04):
  • [25] The accuracy of preoperative implant size prediction achieved by digital templating in total knee arthroplasty is not affected by the quality of lateral knee radiographs
    Pichler, Lorenz
    Klein, Leonhard
    Perka, Carsten F.
    Gwinner, Clemens
    El Kayali, Moses K. D.
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [26] Correlation of Short Knee Radiographs and Full-length Radiographs in Patients Undergoing Total Knee Arthroplasty
    Alzahrani, Mohammad M.
    Wood, Thomas J.
    Somerville, Lyndsay E.
    Howard, James L.
    Lanting, Brent A.
    Vasarhelyi, Edward M.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2019, 27 (11) : E516 - E521
  • [27] Plain Radiographs Fail to Reflect Femoral Offset in Total Hip Arthroplasty
    Weber, Markus
    Woerner, Michael L.
    Springorum, Hans-Robert
    Hapfelmeier, Alexander
    Grifka, Joachim
    Renkawitz, Tobias F.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (08): : 1661 - 1665
  • [28] Bacterial Infection and Implant Loosening in Hip and Knee Arthroplasty: Evaluation of 209 Cases
    Dapunt, Ulrike
    Radzuweit-Mihaljevic, Stephanie
    Lehner, Burkhard
    Haensch, Gertrud Maria
    Ewerbeck, Volker
    MATERIALS, 2016, 9 (11):
  • [29] The effect of implant constraint on results of conversion of unicomnartmental knee arthroplasty to total knee arthroplasty
    Miller, M
    Benjamin, JB
    Marson, B
    Hollstien, S
    ORTHOPEDICS, 2002, 25 (12) : 1353 - 1357
  • [30] Radiologic case study - Patellar component loosening in total knee arthroplasty
    Klassen, C
    Cotter, JR
    Griffiths, HJ
    ORTHOPEDICS, 2006, 29 (03) : 178 - +