Validity of the 30-Second Sit-to-Stand test as a measure of lower extremity function in persons with multiple sclerosis: Preliminary evidence

被引:6
|
作者
Zheng, Peixuan [1 ]
Huynh, Trinh L. T. [2 ]
Jones, C. Danielle [2 ]
Feasel, Corey D. [2 ]
Jeng, Brenda [1 ,2 ]
Motl, Robert W. [1 ,2 ]
机构
[1] Univ Illinois, Coll Appl Hlth Sci, Dept Kinesiol & Nutr, 1919W Taylor St, Chicago, IL 60612 USA
[2] Univ Alabama Birmingham, Sch Hlth Profess, Dept Phys Therapy, Birmingham, AL USA
关键词
Sit-to-stand test; Physical functional; Muscle strength; Multiple sclerosis; Validity; TIMED 25-FOOT WALK; 6-MINUTE WALK; PERFORMANCE; STRENGTH; IMPACT; SCALE; MS; IMPAIRMENT; MOBILITY; BALANCE;
D O I
10.1016/j.msard.2023.104552
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: The 30-Second Sit-To-Stand (30SSTS) is a quick, inexpensive, safe, and widely used clinical measure of lower extremity function. To date, there is limited evidence regarding the use of 30SSTS in multiple sclerosis (MS). The purpose of this study was to examine the construct validity of the 30SSTS test in persons with MS compared with non-MS healthy controls.Methods: Twenty ambulatory persons with MS and twenty age- and sex-matched healthy controls completed the 30SSTS, Timed 25-Foot Walk (T25FW), Timed Up and Go (TUG), Six-Minute Walk (6MW), and Godin LeisureTime Exercise Questionnaire (GLTEQ). Persons with MS also completed the Patient Determined Disease Steps (PDDS) and 12-item MS Walking Scale (MSWS-12).Results: Persons with MS had significantly worse performance on the TUG (mean difference [95% confidence interval] = 1.4 [0.5, 2.3] sec) and 6MW (-259.2 [-450.8, -67.6] ft), but not on the 30SSTS (-1.6 [-1.5, 4.6] reps) and T25FW (-0.59 [-0.1, 1.2] ft/sec) compared with controls. There were significant moderate-to-strong correlations between the 30SSTS with T25FW, TUG, and 6MW scores in persons with MS (r = 0.48, -0.65 and 0.61, respectively), whereas the 30SSTS was only significantly associated with 6MW scores (r = 0.43) in controls. The 30SSTS was negatively associated with MS-related walking disability assessed by the PDDS and MSWS-12 (rs = -0.52 and -0.64, respectively), but was not significantly associated with the GLTEQ in MS and controls (r = 0.30 and 0.17, respectively).Conclusion: This study provides initial support for the construct validity of the 30SSTS as a measure of lower extremity function in persons with MS. Our findings warrant the inclusion of the 30SSTS as a feasible and valid measure of physical function in clinical research and practice involving persons with MS.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Portable Ultrasound-Based Device for Detecting Older Adults' Sit-to-Stand Transitions in Unsupervised 30-Second Chair-Stand Tests
    Cobo, Antonio
    Villalba-Mora, Elena
    Hayn, Dieter
    Ferre, Xavier
    Perez-Rodriguez, Rodrigo
    Sanchez-Sanchez, Alberto
    Bernabe-Espiga, Raquel
    Sanchez-Sanchez, Juan-Luis
    Lopez-Diez-Picazo, Andrea
    Moral, Cristian
    Rodriguez-Manas, Leocadio
    SENSORS, 2020, 20 (07)
  • [22] Intra- and inter-rater reproducibility of the 6-minute walk test and the 30-second sit-to-stand test in patients with severe and very severe COPD
    Hansen, Henrik
    Beyer, Nina
    Frolich, Anne
    Godtfredsen, Nina
    Bieler, Theresa
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2018, 13 : 3447 - 3457
  • [23] Validation of Smartphone Accelerometry for the Evaluation of Sit-To-Stand Performance and Lower-Extremity Function in Older Adults
    Song, Yuwei
    Begum, Momotaz
    Arthanat, Sajay
    LaRoche, Dain P.
    JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2022, 30 (01) : 3 - 11
  • [24] Significance of Preoperative Multidisciplinary Assessment with 30-Second Sit-to-Stand and Timed Up-and-Go Tests in Predicting Postoperative Outcomes
    Yucel, Mucahid Osman
    Saglam, Sonmez
    Dalaslan, Rasit Emin
    Arican, Mehmet
    Karaduman, Zekeriya Okan
    Akar, Bedrettin
    Celik, Mucahit
    Sav, Ismail
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (04)
  • [25] A study of the reliability and construct validity of the 1-minute sit-to-stand test for individuals with systemic sclerosis
    Laursen, Jakob
    Christensen, Amalie
    Egsgaard, Simon
    Sondergaard, Klaus
    Mechlenburg, Inger
    Brincks, John
    PHYSIOTHERAPY THEORY AND PRACTICE, 2024,
  • [26] Exercise capacity prior to major cancer surgery: A cross-sectional observational study of the validity of the 6-minute walk and 30-second sit-to-stand tests
    Butson, Grace
    Edbrooke, Lara
    Ismail, Hilmy
    Denehy, Linda
    ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2024, 20 (04) : 497 - 506
  • [27] Evaluation of unsupervised 30-second chair stand test performance assessed by wearable sensors to predict fall status in multiple sclerosis
    Tulipani, Lindsey J.
    Meyer, Brett
    Allen, Dakota
    Solomon, Andrew J.
    McGinnis, Ryan S.
    GAIT & POSTURE, 2022, 94 : 19 - 25
  • [28] Normative Reference Values and Validity for the 30-Second Chair-Stand Test in Healthy Young Adults
    Lein, Donald H., Jr.
    Alotaibi, Mansour
    Almutairi, Marzouq
    Singh, Harshvardhan
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2022, 17 (05): : 907 - 914
  • [29] Comprehensive Assessment of Lower Limb Function and Muscle Strength in Sarcopenia: Insights from the Sit-to-Stand Test
    Park, Tae Sung
    Shin, Myung-Jun
    ANNALS OF GERIATRIC MEDICINE AND RESEARCH, 2024, 28 (01): : 1 - 8
  • [30] Minimal clinically important difference in 30 second sit-to-stand test after pulmonary rehabilitation in patients with COPD
    Zanini, Andrea
    Crisafulli, Ernesto
    D'Andria, Michele
    Gregorini, Cristina
    Cherubino, Francesca
    Zampogna, Elisabetta
    Azzola, Andrea
    Spanevello, Antonio
    Chetta, Alfredo
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52