摘要
Pneumocystis jirovecii pneumonia (PJP) is a serious and sometimes fatal infection occurring in immunocompromised individuals. High-risk patients include those with low CD4 counts due to human immunodeficiency virus infection and transplant recipients. The incidence of PJP is increasing, and rapid detection of PJP is needed to effectively target treatment and improve patient outcomes. A common method used is an immunofluorescent assay (IFA), which has limitations, including labor costs, low sensitivity, and requirement for expert interpretation. This study evaluates the performance of the DiaSorin Molecular Pneumocystis jirovecii analyte-specific reagent (ASR) in a laboratory-developed test (LDT) for the direct detection of P. jirovecii DNA without prior nucleic acid extraction. Respiratory samples (n = 135) previously tested by IFA from 111 patients were included. Using a composite standard of in-house IFA and reference lab PJP PCR, the percent positive agreement for the LDT using the DiaSorin ASR was 97.8% (90/92). The negative percent agreement was 97.7% (42/43). The lower limit of detection of the assay was determined to be 1,200 copies/mL in bronchoalveolar lavage fluid. Analytical specificity was assessed using cultures of oropharyngeal flora and common respiratory bacterial and fungal pathogens. No cross-reactivity was observed. Our study suggests that the DiaSorin Pneumocystis ASR accurately detects P. jirovecii DNA and demonstrates improved sensitivity compared to the IFA method. IMPORTANCEOur study is unique compared to other previously published studies on the DiaSorin analyte-specific reagent (ASR) because we focused on microbiological diagnostic methods commonly used (immunofluorescent assay) as opposed to pathology findings or reference PCR. In addition, in our materials and methods, we describe the protocol for the use of the DiaSorin ASR as a singleplex assay, which will allow other users to evaluate the ASR for clinical use in their lab.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Evaluation of Sensitivity of Multiplex PCR for Detection of Mycobacterium tuberculosis and Pneumocystis jirovecii in Clinical Samples
    Boondireke, Sirirat
    Mungthin, Mathirut
    Tan-ariya, Peerapan
    Boonyongsunchai, Petchara
    Naaglor, Tawee
    Wattanathum, Anan
    Treewatchareekorn, Sompong
    Leelayoova, Saovanee
    JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (09) : 3165 - 3168
  • [42] The analyte-specific reagent and immunohistochemistry reagent proposals: Overlap and potential impacts on industry
    Chambers, LA
    Takes, PA
    BIOTECHNOLOGY LAW REPORT, 1996, 15 (06): : 909 - 912
  • [43] PneumID-A qPCR kit for the detection of Pneumocystis jirovecii
    Johnson, G. L.
    Kirvell, S.
    Partridge, D.
    Yavuz, M.
    Bustin, S. A.
    MYCOSES, 2017, 60 : 113 - 113
  • [44] Detection of Pneumocystis jirovecii DNA in paraffinized lung tissue
    不详
    INFECTION, 2005, 33 (03) : 234 - 234
  • [45] Evaluation of a real time PCR assay for detection of Pneumocystis jirovecii in bronchoalveolar lavage samples
    Hermann, B.
    Egerer, R.
    Riebold, D.
    Loeffler, B.
    Baier, M.
    MYCOSES, 2015, 58 : 56 - 56
  • [46] Comments regarding a forgotten test for the detection of Pneumocystis jirovecii
    Iturrieta-Gonzalez, Isabel
    REVISTA CHILENA DE INFECTOLOGIA, 2025, 42 (01): : 88 - 88
  • [47] Linear Extrapolation of the Analyte-Specific Light Scattering and Fluorescence Depolarization in Turbid Samples
    Xu, Joanna Xiuzhu
    Liu, Muqiong
    Athukorale, Sumudu
    Zou, Shengli
    Zhang, Dongmao
    ACS OMEGA, 2019, 4 (03): : 4739 - 4747
  • [48] Clinical evaluation of the NucliSENS analyte specific reagents for the detection of respiratory syncytial virus and human metapneumovirus in paediatric respiratory specimens
    Manji, R.
    Zhang, F.
    Lotlikar, M.
    Ginocchio, C.
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2007, 29 : S490 - S491
  • [49] Detection of high-risk papillomavirus DNA with commercial invader-technology-based analyte-specific reagents following automated extraction of DNA from cervical brushings in ThinPrep media
    Schutzbank, Ted E.
    Jarvis, Charlene
    Kahmann, Nicole
    Lopez, Katherine
    Weimer, Marlea
    Yount, Aleta
    JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (12) : 4067 - 4069
  • [50] Pneumocystis jirovecii detection by direct immunofluorescence technique: Five years of experience in Venezuela (2007-2011)
    Panizo, M. M.
    Reviakina, V.
    Garcia, N.
    Ferrara, G.
    Navas, T. M.
    Moreno, X.
    Alarcon, V.
    Dolande, M. E.
    Caceres, A. M.
    Guevara, R. N.
    Leon, M.
    Guzman, M. E.
    Silva, M.
    Figueredo, A.
    MYCOSES, 2012, 55 : 297 - 297