Simulation of Electron-Hole Pairs Created by ?-Rays Interaction in Scintillation Crystals Using Geant4 Toolkit

被引:1
|
作者
Luan, Nguyen Thanh [1 ]
Kim, Hong Joo [1 ]
Vuong, Phan Quoc [1 ]
机构
[1] Kyungpook Natl Univ, Dept Phys, Daegu, South Korea
基金
新加坡国家研究基金会;
关键词
Electron-hole pair (e-h pair); Geant4; inorganic scintillation; longitudinal optical (LO) phonon; Monte-Carlo simulation; plasmon; ENERGY-RESOLUTION SCINTILLATOR; TEMPERATURE-DEPENDENCE; LIGHT YIELD; PURE CSI; EFFICIENCY; CE3+; NAI(TL); PHOTON;
D O I
10.1109/TNS.2023.3271328
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Understanding the electron-hole pair (e-h pair) production process in scintillators is essential for further studies of the scintillation mechanism. The number of e-h pairs can be derived from theoretical and empirical approaches. However, simulation approaches have been chosen to study all the related physical processes and spatial information in scintillation crystals. Due to the complexity of particle interaction and physical properties of solid-state, the simulation approach could be better than the analytical approach. This work aims to develop a Geant4-based simulation toolkit for studying scintillation mechanisms in single-crystalline scintillators since Geant4 can accurately calculate particle energy loss. Due to the lack of a solid-state physics model for insulators, the plasmon creation and phonon loss process for electrons are implemented in the Geant4 toolkit. The electrons, which are created by ?-rays interaction in crystals, can make further ionization to generate secondary electrons or create plasmons, or lose energy to phonons. Then the created plasmons decay into e-h pairs. These electrons and holes are tracked with information on energy and position. Therefore, the number of created e-h pairs and their spatial distribution can be extracted. In this work, we will present the result of the creation process of e-h pairs per MeV in scintillation crystals induced by ?-rays interaction. The number of e-h pairs created by ? ray in some popular inorganic crystals has been calculated. Assuming maximum conversion efficiency from the e-h pair to the luminescence light, we can calculate the maximum light yield of the intrinsic scintillator.
引用
收藏
页码:1312 / 1317
页数:6
相关论文
共 50 条
  • [21] Microdosimetry of Radionuclides Using Geant4 Simulation Considering the Auger Electron Contribution
    Kwon, O.
    Adam, D.
    Bednarz, B.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [22] Simulation of a Typical Wolter-I X-ray Telescope Using the Geant4 Toolkit
    Mehdi, Abbasian Motlagh
    Gohar, Rastegarzadeh
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2023, 66 (03) : 451 - 455
  • [23] Simulation of a Typical Wolter-I X-ray Telescope Using the Geant4 Toolkit
    Abbasian Motlagh Mehdi
    Rastegarzadeh Gohar
    Instruments and Experimental Techniques, 2023, 66 : 451 - 455
  • [24] A comparison of cellular irradiation techniques with alpha particles using the Geant4 Monte Carlo simulation toolkit
    Incerti, S.
    Gault, N.
    Habchi, C.
    Lefaix, J. L.
    Moretto, Ph.
    Poncy, J. L.
    Pouthier, T.
    Seznec, H.
    RADIATION PROTECTION DOSIMETRY, 2006, 122 (1-4) : 327 - 329
  • [25] Signal pulse emulation for scintillation detectors using Geant4 Monte Carlo with light tracking simulation
    Ogawara, R.
    Ishikawa, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (07):
  • [26] Monte Carlo simulation of laser beams interaction with the human eye using Geant4
    Diogo Tendeiro
    Gonçalo Lopes
    Pedro Vieira
    José Paulo Santos
    BioMedical Engineering OnLine, 13
  • [27] Monte Carlo simulation of laser beams interaction with the human eye using Geant4
    Tendeiro, Diogo
    Lopes, Goncalo
    Vieira, Pedro
    Santos, Jose Paulo
    BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [28] Monte Carlo simulation of MOSFET dosimeter for electron backscatter using the GEANT4 code
    Chow, James C. L.
    Leung, Michael K. K.
    MEDICAL PHYSICS, 2008, 35 (06) : 2383 - 2390
  • [29] Dosimetric evaluation of nuclear interaction models in the Geant4 Monte Carlo simulation toolkit for carbon-ion radiotherapy.
    Kameoka S.
    Amako K.
    Iwai G.
    Murakami K.
    Sasaki T.
    Toshito T.
    Yamashita T.
    Aso T.
    Kimura A.
    Kanai T.
    Kanematsu N.
    Komori M.
    Takei Y.
    Yonai S.
    Tashiro M.
    Koikegami H.
    Tomita H.
    Koi T.
    Radiological Physics and Technology, 2008, 1 (2) : 183 - 187
  • [30] Developing an approach for fast estimation of range of ion in interaction with material using the Geant4 toolkit in combination with the neural network
    Moshkbar-Bakhshayesh, Khalil
    Mohtashami, Soroush
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (11) : 4209 - 4214