Techno-Economic Assessment of a 100 kWp Solar Rooftop PV System for Five Hospitals in Central Southern Thailand

被引:4
|
作者
Khamharnphol, Rawit [1 ]
Kamdar, Ismail [2 ]
Waewsak, Jompob [2 ]
Chiwamongkhonkarn, Somphol [3 ]
Khunpetch, Sakrapee [1 ]
Kongruang, Chuleerat [4 ]
Gagnon, Yves [5 ]
机构
[1] Nakhon Si Thammarat Rajabhat Univ, Fac Ind Technol, Nakhon Si Thammarat, Thailand
[2] Thaksin Univ, Fac Sci, Res Ctr Energy & Environm, Phatthalung Campus, Phatthalung, Thailand
[3] Thaksin Univ, Fac Engn, Phatthalung Campus, Phatthalung, Thailand
[4] Walailak Univ, Sch Accountancy & Finance, Nakhon Si Thammarat, Thailand
[5] Univ Moncton, Edmundston, NB, Canada
关键词
Solar Rooftop PV; Bifacial Photovoltaic; Performance Ratio; Levelized Cost of Energy; Economic Analysis; COST-BENEFIT-ANALYSIS; FEED-IN TARIFF; PERFORMANCE ANALYSIS; PHOTOVOLTAIC SYSTEM; POLICY IMPLICATIONS; SELF-CONSUMPTION; RADIATION; ENERGY; BUSINESS; BANGKOK;
D O I
10.14710/ijred.2023.46864
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents a techno-economic assessment of a 100 kWp solar rooftop photovoltaic (PV) system at five hospitals in central southern Thailand. The system encompasses 100 kWp PV panels, 100 kW grid-tied inverters and balance of system (BOS) under the grid code of the Provincial Electricity Authority (PEA). The latest PV technology of bifacial mono-crystalline solar panels, inverters and BOS were simulated along with the Meteonorm 7.3 database using the PVsyst simulation toolkit with different tilt angles, orientations, solar radiations and ambient temperature. The technical aspects of solar rooftop PV power generation systems include the annual energy output and the performance ratio (PR) under IEC standard. Further, an economic analysis of the model was examined using a cost benefit analysis (CBA) and various assumptions. Four main financial criteria, i.e., benefit cost ratio (BCR), net present value (NPV), internal rate of return (IRR), and payback period (PBP) were evaluated under three different scenarios: (1) self-consumption scheme, (2) feed-in tariff (FiT) scheme, and (3) private power purchase agreement (PPA) scheme. Finally, the levelized cost of energy (LCOE) was also calculated. The results reveal that the Takua Thung hospital is characterized by the maximum average global horizontal irradiation (GHI) and the maximum annual produced energy of 199 kWh/m2 and 164.8 MWh/year, respectively. The PR calculated for all hospital sites is above 85%. The outcomes of the financial analysis show that the optimum scenarios are PPA and FiT schemes. The LCOE analysed in this study indicates that the Takua Thung hospital site has the lowest LCOE at 2.47 THB/kWh (0.07 USD/kWh). This research confirms the potential for hospitals and stakeholders in central southern Thailand for investments in solar rooftop PV systems.
引用
收藏
页码:77 / 86
页数:10
相关论文
共 50 条
  • [31] Techno-Economic Assessment of PV System for self-consumption Case Study of Malta
    Jately, Vibhu
    Azzopardi, Brian
    Bartolo, Brian
    Mikalauskiene, Renata
    Bhattacharya, Somesh
    2020 47TH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2020, : 2151 - 2153
  • [32] Techno-Economic Modeling of Wind-Solar PV and Wind-Solar PV-Biomass Hybrid Energy System
    Jagtap, Kunal K.
    Patil, Ganesh
    Katti, P. K.
    Kulkarni, S. B.
    2016 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2016,
  • [33] Energy Efficiency and Economic Survivance Appraisal of a 375 kWp Rooftop Solar PV System Under Hot and Dry Indian Climate
    Poonia, Surendra
    Santra, Priyabrata
    Singh, A. K.
    Singh, Digvijay
    Kumar, Mahesh
    HEAT TRANSFER, 2025, 54 (02) : 1202 - 1216
  • [34] Techno-Economic Assessment of New Material Developments in Central Receiver Solar Power Plants
    Zoschke, Theda
    Frantz, Cathy
    Schttl, Peter
    Fluri, Thomas
    Uhlig, Ralf
    SOLARPACES 2018: INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, 2019, 2126
  • [35] A techno-economic analysis of a solar PV and DC battery storage system for a community energy sharing
    Gul, Eid
    Baldinelli, Giorgio
    Bartocci, Pietro
    Bianchi, Francesco
    Piergiovanni, Domenighini
    Cotana, Franco
    Wang, Jinwen
    ENERGY, 2022, 244
  • [36] Techno-economic analysis of a standalone solar PV with groundwater pumped-hydro-storage system
    Shirinda, K.
    Kusakana, K.
    Koko, S. P.
    PROCEEDINGS OF THE 2019 TWENTY SEVENTH INTERNATIONAL CONFERENCE ON THE DOMESTIC USE OF ENERGY (DUE), 2019, : 90 - 95
  • [37] Performance Assessment and Orientation Optimization of 100 kWp Grid Connected Solar PV System in Indian Scenario
    Ashwini, Kumari
    Raj, Ashish
    Gupta, Manoj
    2016 INTERNATIONAL CONFERENCE ON RECENT ADVANCES AND INNOVATIONS IN ENGINEERING (ICRAIE), 2016,
  • [38] Techno-economic analysis of solar energy system for electrification of rural school in Southern Ethiopia
    Benti, Natei Ermias
    Mekonnen, Yedilfana Setarge
    Asfaw, Ashenafi Abebe
    Lerra, Mulatu Dea
    Woldegiyorgis, Tegenu Argaw
    Gaffe, Chernet Amente
    Aneseyee, Abreham Berta
    COGENT ENGINEERING, 2022, 9 (01):
  • [39] Techno-economic and environmental analysis of a grid-connected rooftop solar photovoltaic system in three climate zones
    Hai, Tao
    Jaffar, Hussein A.
    Taher, Hameed H.
    Al-Rubaye, Ameer H.
    Said, Esraa Ahmed
    Hussein, Abbas Hameed Abdul
    Alhaidry, Wesam Abed A. L. Hassan
    Idan, Ameer Hassan
    Salehi, Abozar
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2024, 19 : 1725 - 1739
  • [40] Performance assessment and orientation optimization of 100 kWp grid connected solar PV system in Indian scenario
    Ashwini, Kumari
    Raj, Ashish
    Gupta, Manoj
    2016 International Conference on Recent Advances and Innovations in Engineering, ICRAIE 2016, 2016,