Techno-Economic Assessment of a 100 kWp Solar Rooftop PV System for Five Hospitals in Central Southern Thailand

被引:4
|
作者
Khamharnphol, Rawit [1 ]
Kamdar, Ismail [2 ]
Waewsak, Jompob [2 ]
Chiwamongkhonkarn, Somphol [3 ]
Khunpetch, Sakrapee [1 ]
Kongruang, Chuleerat [4 ]
Gagnon, Yves [5 ]
机构
[1] Nakhon Si Thammarat Rajabhat Univ, Fac Ind Technol, Nakhon Si Thammarat, Thailand
[2] Thaksin Univ, Fac Sci, Res Ctr Energy & Environm, Phatthalung Campus, Phatthalung, Thailand
[3] Thaksin Univ, Fac Engn, Phatthalung Campus, Phatthalung, Thailand
[4] Walailak Univ, Sch Accountancy & Finance, Nakhon Si Thammarat, Thailand
[5] Univ Moncton, Edmundston, NB, Canada
关键词
Solar Rooftop PV; Bifacial Photovoltaic; Performance Ratio; Levelized Cost of Energy; Economic Analysis; COST-BENEFIT-ANALYSIS; FEED-IN TARIFF; PERFORMANCE ANALYSIS; PHOTOVOLTAIC SYSTEM; POLICY IMPLICATIONS; SELF-CONSUMPTION; RADIATION; ENERGY; BUSINESS; BANGKOK;
D O I
10.14710/ijred.2023.46864
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents a techno-economic assessment of a 100 kWp solar rooftop photovoltaic (PV) system at five hospitals in central southern Thailand. The system encompasses 100 kWp PV panels, 100 kW grid-tied inverters and balance of system (BOS) under the grid code of the Provincial Electricity Authority (PEA). The latest PV technology of bifacial mono-crystalline solar panels, inverters and BOS were simulated along with the Meteonorm 7.3 database using the PVsyst simulation toolkit with different tilt angles, orientations, solar radiations and ambient temperature. The technical aspects of solar rooftop PV power generation systems include the annual energy output and the performance ratio (PR) under IEC standard. Further, an economic analysis of the model was examined using a cost benefit analysis (CBA) and various assumptions. Four main financial criteria, i.e., benefit cost ratio (BCR), net present value (NPV), internal rate of return (IRR), and payback period (PBP) were evaluated under three different scenarios: (1) self-consumption scheme, (2) feed-in tariff (FiT) scheme, and (3) private power purchase agreement (PPA) scheme. Finally, the levelized cost of energy (LCOE) was also calculated. The results reveal that the Takua Thung hospital is characterized by the maximum average global horizontal irradiation (GHI) and the maximum annual produced energy of 199 kWh/m2 and 164.8 MWh/year, respectively. The PR calculated for all hospital sites is above 85%. The outcomes of the financial analysis show that the optimum scenarios are PPA and FiT schemes. The LCOE analysed in this study indicates that the Takua Thung hospital site has the lowest LCOE at 2.47 THB/kWh (0.07 USD/kWh). This research confirms the potential for hospitals and stakeholders in central southern Thailand for investments in solar rooftop PV systems.
引用
收藏
页码:77 / 86
页数:10
相关论文
共 50 条
  • [1] Techno-Economic Analysis of Off-Grid Rooftop Solar PV System
    Sharma, Piyush
    Bojja, Haranath
    Yemula, Pradeep
    2016 IEEE 6TH INTERNATIONAL CONFERENCE ON POWER SYSTEMS (ICPS), 2016,
  • [2] Techno-economic assessment of a hybrid connected PV solar system
    Hasan Falih
    Ahmed J. Hamed
    Abdul Hadi N. Khalifa
    International Journal of Air-Conditioning and Refrigeration, 30
  • [3] Techno-economic assessment of a hybrid connected PV solar system
    Falih, Hasan
    Hamed, Ahmed J.
    Khalifa, Abdul Hadi N.
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2022, 30 (01)
  • [4] Optimization and techno-economic assessment of rooftop photovoltaic system
    Awan, Ahmed Bilal
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2019, 11 (03)
  • [5] Techno-economic assessment of on-grid solar PV system in Palestine
    Ibrik, Imad H.
    COGENT ENGINEERING, 2020, 7 (01):
  • [6] Adaptable pathway to net zero carbon: A case study for Techno-Economic & Environmental assessment of Rooftop Solar PV System
    Agarwal, Umesh
    Rathore, Narendra Singh
    Jain, Naveen
    Sharma, Pawan
    Bansal, Ramesh C.
    Chouhan, Mayur
    Kumawat, Manoj
    ENERGY REPORTS, 2023, 9 : 3482 - 3492
  • [7] Techno-Economic Assessment of Net Energy Metering Implementation for Rooftop Solar PV in a Commercial Building in Bangladesh
    Miah, Muhammad Ahad Rahman
    Rahman, Shaikh Rashedur
    Kabir, Runa
    2020 4TH INTERNATIONAL CONFERENCE ON GREEN ENERGY AND APPLICATIONS (ICGEA 2020), 2020, : 95 - 99
  • [8] Techno-economic analysis of photovoltaic rooftop system on car parking area in Rayong, Thailand
    Mongkoldhumrongkul, Krittaphas
    ENERGY REPORTS, 2023, 9 : 202 - 212
  • [9] Techno-Economic Analysis of Grid-connected Rooftop Solar PV Systems in Saudi Arabia
    Aldahmashi, Nasser
    Khan, Yasin
    Alamoud, Abdulrahman
    2021 IEEE 48TH PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2021, : 2217 - 2221
  • [10] Techno-economic analysis of photovoltaic rooftop system on car parking area in Rayong, Thailand
    Mongkoldhumrongkul, Krittaphas
    ENERGY REPORTS, 2023, 9 : 202 - 212