共 50 条
Accuracy of combined physical examination, transvaginal ultrasonography, and magnetic resonance imaging to diagnose deep endometriosis
被引:11
|作者:
Roditis, Alexis
[1
]
Florin, Marie
[1
]
Rousset, Pascal
[2
]
Touboul, Cyril
[3
]
Bendifallah, Sofiane
[3
]
Bazot, Marc
[1
]
Thomassin-Naggara, Isabelle
[1
]
机构:
[1] Sorbonne Univ, Hop Tenon Serv Imagerie Radiol & intervent special, APHP, Paris, France
[2] Claude Bernard Univ, Ctr Hospitalier Lyon Sud, Dept Radiol, Hosp Civils Lyon, Lyon, France
[3] Sorbonne Univ, Hop Tenon Serv gynecol & Obstet, APHP, Paris, France
关键词:
Endometriosis;
pelvis MR;
clinical examination;
ultrasonography;
diagnostic accuracy;
PARAMETRIAL INVOLVEMENT;
CLINICAL EXAMINATION;
SONOGRAPHY;
WOMEN;
MRI;
D O I:
10.1016/j.fertnstert.2022.12.025
中图分类号:
R71 [妇产科学];
学科分类号:
100211 ;
摘要:
Objectives: To assess the ability of physical examination (PE), transvaginal ultrasonography (TVUS), and magnetic resonance imaging (MRI) alone and combined to diagnose deep infiltrating endometriosis (DIE).Design: We retrospectively queried our pelvic MRI database to identify women who underwent PE, TVUS, and pelvic MRI for DIE up to 12 months before surgery between January 1, 2016 and August 31, 2020. The presence of uterosacral ligaments (USL), vaginal, rectosigmoid (RS), parametrial, or sacrorectogenital septum (lateral) DIE shown by PE, TVUS, and MRI were correlated with surgical and histological findings.Setting: Academic hospital.Patient(s): We included 178 patients.Intervention(s): Clinical and imaging evaluation of women who were diagnosed at surgery with deep pelvic endometriosis.Main Outcome Measure(s): The sensitivity, specificity, positive and negative predictive values, and accuracy of each technique sepa-rately and combined were assessed for each location. When the 3 techniques were combined, 2 models were tested as follows: all 3 techniques positive and concordant; and R2 techniques positive and concordant.Result(s): The prevalence of USL, vaginal, RS, and lateral DIE were 94.4%, 20.2%, 34.3%, and 32.6%, respectively. In addition, MRI was more sensitive than PE, TVUS or any combination to detect DIE. Moreover, MRI and model B were the most accurate for detecting USL and RS locations with an accuracy of 90.4% and 82.6%, a sensitivity of 91.1% and 50%, and a specificity of 77.8% and 90.9%, respec-tively. Model B was the most accurate for the vaginal location with an accuracy, sensitivity, and specificity of 82.6%, 50%, and 90.9%, respectively. Finally, MRI was more accurate than any combination for identifying a lateral location with an accuracy, sensitivity, and specificity of 75.1%, 36%, and 93.8%, respectively. Conclusion(s): A combination of PE, TVUS, and MRI was more accurate than each technique separately to diagnose DIE because of the equally high sensitivity of each, as well as the high specificity of PE and TVUS. (Fertil Sterile 2023;119:634-43.(c) 2022 by American Society for Reproductive Medicine.)El resumen esta disponible en Espanol al final del articulo.
引用
收藏
页码:634 / 643
页数:10
相关论文