A comprehensive lung CT landmark pair dataset for evaluating deformable image registration algorithms

被引:2
|
作者
Criscuolo, Edward R. [1 ]
Fu, Yabo [2 ]
Hao, Yao [3 ]
Zhang, Zhendong [1 ]
Yang, Deshan [1 ,4 ]
机构
[1] Duke Univ, Dept Radiat Oncol, Durham, NC USA
[2] Mem Sloan Kettering Canc Ctr, New York, NY USA
[3] Washington Univ, Sch Med, St Louis, MO USA
[4] Duke Univ, Sch Med, Dept Radiat Oncol, 40 Duke Med Circle, Room 04212, 3640 DUMC, Durham, NC 27710 USA
关键词
deformable image registration; ground truth dataset; lung motion; COMPUTED-TOMOGRAPHY; MOTION ESTIMATION; ACCURACY; MORPHOMETRY; HEAD;
D O I
10.1002/mp.17026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeDeformable image registration (DIR) is a key enabling technology in many diagnostic and therapeutic tasks, but often does not meet the required robustness and accuracy for supporting clinical tasks. This is in large part due to a lack of high-quality benchmark datasets by which new DIR algorithms can be evaluated. Our team was supported by the National Institute of Biomedical Imaging and Bioengineering to develop DIR benchmark dataset libraries for multiple anatomical sites, comprising of large numbers of highly accurate landmark pairs on matching blood vessel bifurcations. Here we introduce our lung CT DIR benchmark dataset library, which was developed to improve upon the number and distribution of landmark pairs in current public lung CT benchmark datasets.Acquisition and Validation MethodsThirty CT image pairs were acquired from several publicly available repositories as well as authors' institution with IRB approval. The data processing workflow included multiple steps: (1) The images were denoised. (2) Lungs, airways, and blood vessels were automatically segmented. (3) Bifurcations were directly detected on the skeleton of the segmented vessel tree. (4) Falsely identified bifurcations were filtered out using manually defined rules. (5) A DIR was used to project landmarks detected on the first image onto the second image of the image pair to form landmark pairs. (6) Landmark pairs were manually verified. This workflow resulted in an average of 1262 landmark pairs per image pair. Estimates of the landmark pair target registration error (TRE) using digital phantoms were 0.4 mm +/- 0.3 mm.Data Format and Usage NotesThe data is published in Zenodo at . Instructions for use can be found at .Potential ApplicationsThe dataset library generated in this work is the largest of its kind to date and will provide researchers with a new and improved set of ground truth benchmarks for quantitatively validating DIR algorithms within the lung.
引用
收藏
页码:3806 / 3817
页数:12
相关论文
共 50 条
  • [41] A new validation method of thoracic CT to CT deformable image registration
    Dawoud, S. M.
    Smith, D. W.
    Roberts, N.
    Sebag-Montefiore, D. J.
    Crellin, A. M.
    Crosby, T.
    Radhakrishna, G.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S247 - S247
  • [43] An unsupervised deep learning framework for large-scale lung CT deformable image registration
    Zhao, Yuqian
    Xie, Zhongyu
    Zhang, Fan
    Liao, Miao
    Di, Shuanhu
    OPTICS AND LASER TECHNOLOGY, 2024, 170
  • [44] Sensitivity of 4D-CT Pulmonary Ventilation Imaging to Deformable Image Registration Algorithms and Metrics
    Yamamoto, T.
    Kabus, S.
    Klinder, T.
    Lorenz, C.
    von Berg, J.
    Keall, P.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [45] Validation of deformable image registration algorithms on CT images of ex vivo porcine bladders with fiducial markers
    Wognum, S.
    Heethuis, S. E.
    Rosario, T.
    Hoogeman, M. S.
    Bel, A.
    MEDICAL PHYSICS, 2014, 41 (07)
  • [46] Technical Note: A method for quality assurance of landmark sets for use in evaluation of deformable image registration accuracy of lung parenchyma
    Guy, Christopher L.
    Weiss, Elisabeth
    Jan, Nuzhat
    Christensen, Gary E.
    Hugo, Geoffrey D.
    MEDICAL PHYSICS, 2019, 46 (02) : 766 - 773
  • [47] Is Deformable PET/CT Registration for Contouring Target Volume Superior to Rigid Image Registration in Lung Cancer Radiation Therapy?
    Dincbas, H. F.
    Oksuz, D. C.
    Ergen, S. A.
    Ozuynuk, G.
    Bol, Z.
    Bakir, A.
    Karacam, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S641 - S641
  • [48] Comparison of Two Deformable Registration Algorithms in the Presence of Radiologic Change Between Serial Lung CT Scans
    Cunliffe, Alexandra R.
    White, Bradley
    Justusson, Julia
    Straus, Christopher
    Malik, Renuka
    Al-Hallaq, Hania A.
    Armato, Samuel G., III
    JOURNAL OF DIGITAL IMAGING, 2015, 28 (06) : 755 - 760
  • [49] Comparison of Two Deformable Registration Algorithms in the Presence of Radiologic Change Between Serial Lung CT Scans
    Alexandra R. Cunliffe
    Bradley White
    Julia Justusson
    Christopher Straus
    Renuka Malik
    Hania A. Al-Hallaq
    Samuel G. Armato
    Journal of Digital Imaging, 2015, 28 : 755 - 760
  • [50] Evaluating the Necessity of Adaptive RT and the Role of Deformable Image Registration in Lung Cancer with Different Pathologic Classifications
    Kim, Woo Chul
    Won, Yong Kyun
    Lee, Sang Mi
    Heo, Nam Hun
    Yeo, Seung-Gu
    Chang, Ah Ram
    Bae, Sun Hyun
    Kim, Jae Sik
    Yoo, Ik Dong
    Hong, Sun-pyo
    Min, Chul Kee
    Jo, In Young
    Kim, Eun Seog
    DIAGNOSTICS, 2023, 13 (18)