A comprehensive lung CT landmark pair dataset for evaluating deformable image registration algorithms

被引:2
|
作者
Criscuolo, Edward R. [1 ]
Fu, Yabo [2 ]
Hao, Yao [3 ]
Zhang, Zhendong [1 ]
Yang, Deshan [1 ,4 ]
机构
[1] Duke Univ, Dept Radiat Oncol, Durham, NC USA
[2] Mem Sloan Kettering Canc Ctr, New York, NY USA
[3] Washington Univ, Sch Med, St Louis, MO USA
[4] Duke Univ, Sch Med, Dept Radiat Oncol, 40 Duke Med Circle, Room 04212, 3640 DUMC, Durham, NC 27710 USA
关键词
deformable image registration; ground truth dataset; lung motion; COMPUTED-TOMOGRAPHY; MOTION ESTIMATION; ACCURACY; MORPHOMETRY; HEAD;
D O I
10.1002/mp.17026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeDeformable image registration (DIR) is a key enabling technology in many diagnostic and therapeutic tasks, but often does not meet the required robustness and accuracy for supporting clinical tasks. This is in large part due to a lack of high-quality benchmark datasets by which new DIR algorithms can be evaluated. Our team was supported by the National Institute of Biomedical Imaging and Bioengineering to develop DIR benchmark dataset libraries for multiple anatomical sites, comprising of large numbers of highly accurate landmark pairs on matching blood vessel bifurcations. Here we introduce our lung CT DIR benchmark dataset library, which was developed to improve upon the number and distribution of landmark pairs in current public lung CT benchmark datasets.Acquisition and Validation MethodsThirty CT image pairs were acquired from several publicly available repositories as well as authors' institution with IRB approval. The data processing workflow included multiple steps: (1) The images were denoised. (2) Lungs, airways, and blood vessels were automatically segmented. (3) Bifurcations were directly detected on the skeleton of the segmented vessel tree. (4) Falsely identified bifurcations were filtered out using manually defined rules. (5) A DIR was used to project landmarks detected on the first image onto the second image of the image pair to form landmark pairs. (6) Landmark pairs were manually verified. This workflow resulted in an average of 1262 landmark pairs per image pair. Estimates of the landmark pair target registration error (TRE) using digital phantoms were 0.4 mm +/- 0.3 mm.Data Format and Usage NotesThe data is published in Zenodo at . Instructions for use can be found at .Potential ApplicationsThe dataset library generated in this work is the largest of its kind to date and will provide researchers with a new and improved set of ground truth benchmarks for quantitatively validating DIR algorithms within the lung.
引用
收藏
页码:3806 / 3817
页数:12
相关论文
共 50 条
  • [1] A vessel bifurcation liver CT landmark pair dataset for evaluating deformable image registration algorithms
    Zhang, Zhendong
    Criscuolo, Edward Robert
    Hao, Yao
    Mckeown, Trevor
    Yang, Deshan
    MEDICAL PHYSICS, 2024,
  • [2] Deformable registration of 4D-CT lung image using landmark tracking
    Wu, Junha
    Hu, Bingfeng
    Yang, Xuan
    BIOMEDICAL RESEARCH-INDIA, 2016, 27 (03): : 801 - 811
  • [3] Automatic landmark generation for deformable image registration evaluation for 4D CT images of lung
    Vickress, J.
    Battista, J.
    Barnett, R.
    Morgan, J.
    Yartsev, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (20): : 7236 - 7245
  • [4] Hybrid multiscale landmark and deformable image registration
    Paquin, Dana
    Levy, Doron
    Xing, Lei
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2007, 4 (04) : 711 - 737
  • [5] Automated Landmark-Guided CT to Cone-Beam CT Deformable Image Registration
    Kearney, V.
    Gu, X.
    Chen, S.
    Jiang, L.
    Liu, H.
    Chiu, T.
    Yordy, J.
    Nedzi, L.
    Mao, W.
    MEDICAL PHYSICS, 2014, 41 (06) : 500 - 500
  • [6] Algorithm for Multiscale Residual Deformable Lung CT Image Registration
    Liu, Weipeng
    Li, Xu
    Ren, Ziwen
    Qi, Yedong
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2024, 52 (10): : 135 - 145
  • [7] Biomechanical Deformable Image Registration of Longitudinal Lung CT Images
    Cazoulat, G.
    Owen, D.
    Matuszak, M.
    Balter, J.
    Brock, K.
    MEDICAL PHYSICS, 2015, 42 (06) : 3285 - 3285
  • [8] Mass Transportation for Deformable Image Registration with Application to Lung CT
    Papiez, Bartlomiej W.
    Brady, Michael
    Schnabel, Julia A.
    MOLECULAR IMAGING, RECONSTRUCTION AND ANALYSIS OF MOVING BODY ORGANS, AND STROKE IMAGING AND TREATMENT, 2017, 10555 : 66 - 74
  • [9] Automated landmark-guided deformable image registration
    Kearney, Vasant
    Chen, Susie
    Gu, Xuejun
    Chiu, Tsuicheng
    Liu, Honghuan
    Jiang, Lan
    Wang, Jing
    Yordy, John
    Nedzi, Lucien
    Mao, Weihua
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (01): : 101 - 116
  • [10] Landmark-Driven Interactive Deformable Image Registration
    Shusharina, N.
    Pieper, S.
    Sharp, G.
    MEDICAL PHYSICS, 2013, 40 (06)