TCSC Application for Transient Stabilization of Wind Turbine with Fixed Speed Induction Generator

被引:1
|
作者
Sobhani, Hossein [1 ]
Jannesar, Mohammad Rasol [1 ]
Hasanvand, Saeed [2 ]
Khaledian, Amir [1 ]
机构
[1] Tech & Vocat Univ TVU, Dept Elect Engn, Tehran, Iran
[2] Firouzabad Inst Higher Educ, Dept Elect Engn, Firouzabad, Fars, Iran
关键词
FROG-LEAPING ALGORITHM; POWER-SYSTEM; STABILITY IMPROVEMENT; BRAKING RESISTOR; CONTROLLER; STATCOM; ENHANCEMENT; VOLTAGE;
D O I
10.1155/2023/8193592
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Wind turbines (WTs) are a desirable alternative to traditional nonrenewable power resources as a result of recent environmental concerns. Some of them are fixed speed wind generator (FSWG) and have been integrated to power system by squirrel cage induction generator (SCIG). Induction machine absorbs reactive power during all operating conditions, especially at fault condition may result in severe voltage drop which can lead to generator outage. This outage disconnects a significant amount of active power and consequently leads to frequency instability. In order to prevent induction generator (IG) outages in short circuit failures, this paper investigates thyristor-controlled series capacitor (TCSC) device as a candidate solution. TCSC compensates the IG terminal voltage drop by adjusting transmission line impedance at fault condition. In the proposed method, a metaheuristic technique means that shuffled frog leaping algorithm (SFLA) has been utilized to optimize the TCSC controller gains. The proposed scheme can be applied for both SCIGs and wound rotor induction generators (WRIGs) which is another advantage of this method. Single-machine infinite bus system is considered as case study, and various operating conditions and disturbances have been considered to verify the effectiveness of the proposed method.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Dynamic Modelling and Control of Doubly Fed Induction Generator Variable Speed Wind Turbine
    Moussavi, Seyed Zeinolabedin
    Atapour, Reza
    COMPUTATIONAL INTELLIGENCE AND INFORMATION TECHNOLOGY, 2011, 250 : 78 - +
  • [32] Speed sensorless control for full-scale converter of wind turbine with induction generator
    1600, Science and Engineering Research Support Society (09):
  • [33] Effects of electrical and mechanical parameters on the transient voltage stability of a fixed speed wind turbine
    Dusonchet, Luigi
    Telaretti, Enrico
    ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (07) : 1308 - 1316
  • [34] Voltage sensitivity to capacitor switching on an existing fixed speed induction generator wind farm
    Steurer, M.
    Langston, J.
    Anderson, L.
    Suryanarayanan, S.
    Meeker, R.
    Ribeiro, P.
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 3868 - 3871
  • [35] INTERFACING A FIXED-PITCH-ANGLE WIND TURBINE WITH A DOUBLE-OUTPUT INDUCTION GENERATOR
    SALAMEH, ZM
    ENERGY, 1986, 11 (10) : 941 - 947
  • [36] TRANSIENT ANALYSIS OF VARIABLE SPEED WIND TURBINE
    Kairous, Djilali
    Belmadani, Bachir
    Benghanem, Mostapha
    ECT 2009: ELECTRICAL AND CONTROL TECHNOLOGIES, 2009, : 318 - +
  • [37] Transient Performance of Self-Excited Wind-Turbine Induction Generator Under Induction Motor Load
    Aree, Pichai
    TENCON 2014 - 2014 IEEE REGION 10 CONFERENCE, 2014,
  • [38] Comparison and evaluation of induction generator models in wind turbine systems for transient stability of power system
    Li, H.
    Chen, Z.
    Han, L.
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 2054 - +
  • [39] Battery Charging Using Doubly Fed Induction Generator Connected to Variable Speed Wind Turbine
    Jain, Anjana
    Balaji, S. N.
    Chandel, Mayank Singh
    Sreedhar, S.
    Srilekha, G.
    SMART GRID TECHNOLOGIES (ICSGT- 2015), 2015, 21 : 619 - 624
  • [40] Dynamic response of doubly fed induction generator variable speed wind turbine under fault
    El-Sattar, A. A.
    Saad, N. H.
    El-Dein, M. Z. Shams
    ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (07) : 1240 - 1246