Online protein digestion in membranes between capillary electrophoresis and mass spectrometry

被引:3
|
作者
Ryan, Kendall A. [1 ]
Bruening, Merlin L. [1 ,2 ]
机构
[1] Univ Notre Dame, Dept Chem & Biochem, Notre Dame, IN 46556 USA
[2] Univ Notre Dame, Dept Chem & Biomol Engn, Notre Dame, IN 46556 USA
基金
美国国家科学基金会;
关键词
REVERSED-PHASE HPLC; RETENTION TIME PREDICTION; LIQUID-CHROMATOGRAPHY; ZONE-ELECTROPHORESIS; ACCURATE MASS; TOP-DOWN; MIGRATION BEHAVIOR; TRYPTIC PEPTIDES; DISULFIDE BONDS; LC-MS/MS;
D O I
10.1039/d3an00106g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This research employs pepsin-containing membranes to digest proteins online after a capillary electrophoresis (CE) separation and prior to tandem mass spectrometry. Proteolysis after the separation allows the peptides from a given protein to enter the mass spectrometer in a single plug. Thus, migration time can serve as an additional criterion for confirming the identification of a peptide. The membrane resides in a sheath-flow electrospray ionization (ESI) source to enable digestion immediately before spray into the mass spectrometer, thus limiting separation of the digested peptides. Using the same membrane, digestion occurred reproducibly during 20 consecutive CE analyses performed over a 10 h period. Additionally, after separating a mixture of six unreduced proteins with CE, online digestion facilitated protein identification with at least 2 identifiable peptides for all the proteins. Sequence coverages were >75% for myoglobin and carbonic anhydrase II but much lower for proteins containing disulfide bonds. Development of methods for efficient separation of reduced proteins or identification of cross-linked peptides should enhance sequence coverages for proteins with disulfide bonds. Migration times for the peptides identified from a specific protein differed by <similar to 30 s, which allows for rejection of some spurious peptide identifications.
引用
收藏
页码:1611 / 1619
页数:9
相关论文
共 50 条
  • [21] An interface for online coupling capillary electrophoresis to dielectric barrier discharge ionization mass spectrometry
    Zhang, Yiding
    Ai, Wanpeng
    Bai, Yu
    Zhou, Yinglin
    Wen, Luhong
    Zhang, Xinxiang
    Liu, Huwei
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (30) : 8655 - 8661
  • [22] ONLINE PRECONCENTRATION CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY (PC-CE-MS)
    TOMLINSON, AJ
    BENSON, LM
    BRADDOCK, WD
    ODA, RP
    NAYLOR, S
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1994, 17 (10): : 729 - 731
  • [23] Analysis of buserelin in urine by online combination of capillary zone electrophoresis with electrospray mass spectrometry
    Stanova, Andrea
    Marak, Jozef
    Maier, Vitezslav
    Ranc, Vaclav
    Znaleziona, Joanna
    Sevcik, Juraj
    Kaniansky, Dusan
    ELECTROPHORESIS, 2010, 31 (07) : 1234 - 1240
  • [24] Quantitation in capillary electrophoresis-mass spectrometry
    Ohnesorge, J
    Neusüss, C
    Wätzig, H
    ELECTROPHORESIS, 2005, 26 (21) : 3973 - 3987
  • [25] Nonaqueous capillary electrophoresis-mass spectrometry
    Scriba, Gerhard K. E.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1159 (1-2) : 28 - 41
  • [26] Advances in capillary electrophoresis mass spectrometry for metabolomics
    Soga, Tomoyoshi
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2023, 158
  • [27] How coupled are capillary electrophoresis and mass spectrometry?
    Ceribeli, Caroline
    Ferraz de Arruda, Henrique
    da Fontoura Costa, Luciano
    SCIENTOMETRICS, 2021, 126 (05) : 3841 - 3851
  • [28] CAPILLARY ZONE ELECTROPHORESIS-MASS SPECTROMETRY
    OLIVARES, JA
    NGUYEN, NT
    SMITH, RD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 204 - ANYL
  • [29] Analysis of surfactants by capillary electrophoresis mass spectrometry
    Tanaka, Y
    Kishimoto, Y
    Otsuka, K
    Terabe, S
    BUNSEKI KAGAKU, 1998, 47 (09) : 563 - 569
  • [30] Dating Silk By Capillary Electrophoresis Mass Spectrometry
    Moini, Mehdi
    Klauenberg, Kathryn
    Ballard, Mary
    ANALYTICAL CHEMISTRY, 2011, 83 (19) : 7577 - 7581