Online protein digestion in membranes between capillary electrophoresis and mass spectrometry

被引:3
|
作者
Ryan, Kendall A. [1 ]
Bruening, Merlin L. [1 ,2 ]
机构
[1] Univ Notre Dame, Dept Chem & Biochem, Notre Dame, IN 46556 USA
[2] Univ Notre Dame, Dept Chem & Biomol Engn, Notre Dame, IN 46556 USA
基金
美国国家科学基金会;
关键词
REVERSED-PHASE HPLC; RETENTION TIME PREDICTION; LIQUID-CHROMATOGRAPHY; ZONE-ELECTROPHORESIS; ACCURATE MASS; TOP-DOWN; MIGRATION BEHAVIOR; TRYPTIC PEPTIDES; DISULFIDE BONDS; LC-MS/MS;
D O I
10.1039/d3an00106g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This research employs pepsin-containing membranes to digest proteins online after a capillary electrophoresis (CE) separation and prior to tandem mass spectrometry. Proteolysis after the separation allows the peptides from a given protein to enter the mass spectrometer in a single plug. Thus, migration time can serve as an additional criterion for confirming the identification of a peptide. The membrane resides in a sheath-flow electrospray ionization (ESI) source to enable digestion immediately before spray into the mass spectrometer, thus limiting separation of the digested peptides. Using the same membrane, digestion occurred reproducibly during 20 consecutive CE analyses performed over a 10 h period. Additionally, after separating a mixture of six unreduced proteins with CE, online digestion facilitated protein identification with at least 2 identifiable peptides for all the proteins. Sequence coverages were >75% for myoglobin and carbonic anhydrase II but much lower for proteins containing disulfide bonds. Development of methods for efficient separation of reduced proteins or identification of cross-linked peptides should enhance sequence coverages for proteins with disulfide bonds. Migration times for the peptides identified from a specific protein differed by <similar to 30 s, which allows for rejection of some spurious peptide identifications.
引用
收藏
页码:1611 / 1619
页数:9
相关论文
共 50 条
  • [1] On-line protein digestion by immobilized enzyme microreactor capillary electrophoresis-mass spectrometry
    Villegas, Lorena
    Pero-Gascon, Roger
    Benavente, Fernando
    Barbosa, Jose
    Sanz-Nebot, Victoria
    TALANTA, 2019, 199 : 116 - 123
  • [2] Attomole protein characterization by capillary electrophoresis mass spectrometry
    Valaskovic, GA
    Kelleher, NL
    McLafferty, FW
    SCIENCE, 1996, 273 (5279) : 1199 - 1202
  • [3] Capillary electrophoresis - Mass spectrometry
    不详
    SPECTROSCOPY, 2003, : 40 - 40
  • [4] Capillary electrophoresis mass spectrometry
    Smith, RD
    Udseth, HR
    Wahl, JH
    Goodlett, DR
    Hofstadler, SA
    HIGH RESOLUTION SEPARATION AND ANALYSIS OF BIOLOGICAL MACROMOLECULES, PT B: APPLICATIONS, 1996, 271 : 448 - 486
  • [5] CAPILLARY ELECTROPHORESIS/MASS SPECTROMETRY
    SMITH, RD
    WAHL, JH
    GOODLETT, DR
    HOFSTADLER, SA
    ANALYTICAL CHEMISTRY, 1993, 65 (13) : A574 - A584
  • [6] CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY
    CAI, JY
    HENION, J
    JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) : 667 - 692
  • [7] CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY
    NIESSEN, WMA
    TJADEN, UR
    VANDERGREEF, J
    JOURNAL OF CHROMATOGRAPHY, 1993, 636 (01): : 3 - 19
  • [8] Development of a miniaturized injection cell for online electrochemistry–capillary electrophoresis–mass spectrometry
    Thomas Herl
    Nicole Heigl
    Frank-Michael Matysik
    Monatshefte für Chemie - Chemical Monthly, 2018, 149 : 1685 - 1691
  • [9] ONLINE CAPILLARY ELECTROPHORESIS ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY OF NUCLEOTIDES
    ZHAO, ZX
    WAHL, JH
    UDSETH, HR
    HOFSTADLER, SA
    FUCIARELLI, AF
    SMITH, RD
    ELECTROPHORESIS, 1995, 16 (03) : 389 - 395
  • [10] Online coupling of capillary electrophoresis with mass spectrometry for the identification of biomarkers for clinical diagnosis
    Weissinger, Eva M.
    Hertenstein, Bernd
    Mischak, Harald
    Ganser, Arnold
    EXPERT REVIEW OF PROTEOMICS, 2005, 2 (05) : 639 - 647