Rapid Detection of Estrogens in Cosmetics by Chemical Derivatization and Paper-Spray Ionization Mass-Spectrometry

被引:3
|
作者
Song, Dongning [1 ,2 ]
Yuan, Song [1 ,2 ]
Zhang, Caiyu [1 ,2 ]
Luan, Lin [1 ,2 ]
Liu, Yang [1 ,2 ]
Zhang, Qingsheng [1 ,2 ]
机构
[1] Natl Inst Food & Drug Control, Beijing 102629, Peoples R China
[2] NMPA Key Lab Qual Res & Evaluat Chem Drugs, Beijing 102629, Peoples R China
来源
MOLECULES | 2023年 / 28卷 / 03期
关键词
paper-spray ionization mass spectrometry (PSI-MS); estrogens; cosmetics; chemical derivatization; ESTRADIOL; ESTRIOL; ESTRONE; SAMPLES;
D O I
10.3390/molecules28031130
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Estrogens in personal care products are harmful to customers. Conventional methods such as HPLC and LC-MS require tedious sample pretreatment and long analytical time. Paper-spray ionization mass spectrometry (PSI-MS) is a powerful tool for the determination of compounds with little time and minimal pretreatment procedures. Since most estrogens show poor responses in PSI-MS, we developed a chemical derivatization and PSI-MS method to determinate three estrogens: estradiol, estriol and ethinyloestradiol with estradiol valerate as the internal standard (I.S.). After derivatization with 2-fluoro-1-methyl-pyridinium-p-toluene-sulfonate, the three estrogens could be quantified in seconds. This method showed good linearity in the range of 0.1 similar to 30 mu g.mL(-1), with R-2 > 0.999. Their recovery results were all between 85%similar to 115%. The limits of detection (LOD) were 0.04 mu g.mL(-1), 0.02 mu g.mL(-1) and 0.02 mu g.mL(-1) for estradiol, estriol and ethinyloestradiol respectively, which improved around 200, 2000, and 900 times compared to non-derivative PSI-MS. The method could quantitatively determine estrogens in cosmetics.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] ANALYSIS OF PETROPORPHYRINS BY CHEMICAL IONIZATION MASS-SPECTROMETRY
    SHAW, GJ
    QUIRKE, JME
    EGLINTON, G
    JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 1, 1978, (12): : 1655 - 1659
  • [42] CHEMICAL IONIZATION MASS-SPECTROMETRY - HARRISON,AG
    MUNSON, B
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1984, 106 (09) : 2740 - 2740
  • [43] HYDROGEN CHEMICAL IONIZATION MASS-SPECTROMETRY OF METALLOPORPHYRINS
    EVERSHED, RP
    WOLFF, GA
    SHAW, GJ
    EGLINTON, G
    ORGANIC MASS SPECTROMETRY, 1985, 20 (07): : 445 - 453
  • [44] ACETONE CHEMICAL IONIZATION MASS-SPECTROMETRY OF MONOSACCHARIDES
    WANG, GH
    SHA, YX
    XU, ZL
    PAN, JG
    ANALYTICAL CHEMISTRY, 1985, 57 (12) : 2283 - 2286
  • [45] ACTIVE HYDROGEN BY CHEMICAL IONIZATION MASS-SPECTROMETRY
    LIN, YY
    SMITH, LL
    BIOMEDICAL MASS SPECTROMETRY, 1979, 6 (01): : 15 - 18
  • [46] IDENTIFICATION OF OPIUM BY CHEMICAL IONIZATION MASS-SPECTROMETRY
    ZITRIN, S
    YINON, J
    ANALYTICAL LETTERS, 1977, 10 (03) : 235 - 241
  • [47] NEGATIVE CHEMICAL IONIZATION MASS-SPECTROMETRY OF EXPLOSIVES
    BOUMA, WJ
    JENNINGS, KR
    ORGANIC MASS SPECTROMETRY, 1981, 16 (08): : 331 - 335
  • [48] DIRECT CHEMICAL IONIZATION MASS-SPECTROMETRY OF CARBOHYDRATES
    REINHOLD, VN
    METHODS IN ENZYMOLOGY, 1987, 138 : 59 - 84
  • [49] CHEMICAL IONIZATION MASS-SPECTROMETRY OF ORGANOPHOSPHORUS INSECTICIDES
    HOLMSTEAD, RL
    CASIDA, JE
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1974, 57 (05): : 1050 - 1055
  • [50] IDENTIFICATION OF STEROIDS BY CHEMICAL IONIZATION MASS-SPECTROMETRY
    LIN, YY
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1980, 57 (02) : A150 - A151