Performance of a force-restricted viscous mass damper incorporated into base-isolated liquid storage tanks

被引:7
|
作者
Tang, Zian [1 ]
Zhu, Hongping [1 ]
Luo, Hao [1 ]
Li, Tao [2 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Civil & Hydraul Engn, Wuhan 430074, Peoples R China
[2] Sichuan Univ, Key Lab Sichuan Prov, Failure Mech & Engn Disaster Prevent, Chengdu 610065, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Base-isolation systems; Liquid storage tanks; Viscous mass damper; Force restriction mechanism; Inerter-based damper; SEISMIC RESPONSE; OPTIMAL-DESIGN; INERTER; VIBRATION; MITIGATION; EARTHQUAKE; STABILITY; BEARINGS; FAULT;
D O I
10.1016/j.istruc.2024.106002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Base isolation systems have been widely used to protect large liquid storage tanks (LSTs) from the damaging effect induced by strong earthquake events. In the previous study, viscous mass dampers (VMDs) were incorporated into the isolation layer for suppressing the isolator displacement and liquid sloshing responses of baseisolated LSTs under long-period ground motions. However, it was recently concerned that VMDs may degrade the isolation performance under more commonly occurring short-period ground motions because of their excessive dynamic stiffness and control forces at high frequencies. To address this issue, a modified VMD with a force-restriction mechanism, referred to as force-restricted viscous mass damper (FRVMD), was employed to enhance the seismic performance of base-isolated LSTs. The acceleration and control force transmissibility of the FRVMD controlled system was investigated by using the harmonic balance with alternating frequency/time domain (HB-AFT) method, and compared with the traditional damping devices. A base-isolated benchmark LST model was employed as a numerical example to identify the benefits of FRVMDs in protecting base-isolated LSTs from short- and long-period ground motions, where the result showed that the FRVMD can effectively suppress the isolator displacement and liquid sloshing response of base-isolated LSTs without compromising the base shear. Furthermore, parametric studies were conducted to investigate the influence of aspect ratios, isolation periods, and restriction forces of FRVMDs on the seismic response of the controlled LST. It was suggested that the performance of the FRVMD controlled structure was robust against the variation of aspect ratios and isolation periods.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Equivalent linear stochastic seismic analysis of cylindrical base-isolated liquid storage tanks
    Curadelli, O.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 83 : 166 - 176
  • [22] Effects of Uncertain Soil Parameters on Seismic Responses of Fixed Base and Base-Isolated Liquid Storage Tanks
    Kumar, Hitesh
    Saha, Sandip Kumar
    JOURNAL OF EARTHQUAKE ENGINEERING, 2024, 28 (01) : 176 - 201
  • [23] Seismic design of base-isolated LNG-storage-tanks
    Baumann, Thomas
    Bohler, Joachim
    Structural Engineering International: Journal of the International Association for Bridge and Structural Engineering (IABSE), 2001, 11 (02): : 139 - 144
  • [24] Optimizing the seismic response of base-isolated liquid storage tanks using swarm intelligence algorithms
    Tsipianitis, Alexandros
    Tsompanakis, Yiannis
    COMPUTERS & STRUCTURES, 2021, 243
  • [25] Optimum parameters and performance of tuned mass damper-inerter for base-isolated structures
    Jangid, Radhey Shyam
    SMART STRUCTURES AND SYSTEMS, 2022, 29 (04) : 549 - 560
  • [26] Seismic analysis of base-isolated liquid storage tanks using the BE-FE-BE coupling technique
    Kim, MK
    Lim, YM
    Cho, SY
    Cho, KH
    Lee, KW
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2002, 22 (9-12) : 1151 - 1158
  • [27] Influence of isolation system characteristic strength on the earthquake behavior of base-isolated liquid storage tanks
    Alhan, C.
    Gazi, H.
    Guler, E.
    INDIAN JOURNAL OF ENGINEERING AND MATERIALS SCIENCES, 2018, 25 (04) : 346 - 352
  • [28] Performance limits of base-isolated liquid storage tanks with/without supplemental dampers under near-fault earthquakes
    Guler, Elif
    Alhan, Cenk
    STRUCTURES, 2021, 33 : 355 - 367
  • [29] Enhanced Energy Dissipation of Tuned Negative Stiffness Viscous Mass Damper (TNSVMD) for the Base-Isolated Structure (BIS)
    Lyu, Qing
    Fu, Bo
    Tian, Siming
    Zhu, Baijie
    Liu, Liangkun
    Zhang, Zhaoyang
    Ye, Jinxun
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2024,
  • [30] Performance improvement of base-isolated structures by the tuned negative stiffness-inertial mass damper
    Gao H.
    Xing C.
    Wang H.
    Gao W.
    Liang R.
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2023, 53 (04): : 592 - 599