Assessment of deep learning segmentation for real-time free-breathing cardiac magnetic resonance imaging at rest and under exercise stress

被引:2
|
作者
Schilling, Martin [1 ]
Unterberg-Buchwald, Christina [1 ,2 ,3 ]
Lotz, Joachim [1 ]
Uecker, Martin [1 ,2 ,4 ]
机构
[1] Univ Med Gottingen, Inst Diagnost & Intervent Radiol, Gottingen, Germany
[2] German Ctr Cardiovasc Res DZHK, Partner Site Gottingen, Gottingen, Germany
[3] Univ Med Gottingen, Clin Cardiol & Pneumol, Gottingen, Germany
[4] Graz Univ Technol, Inst Biomed Imaging, Graz, Austria
关键词
MRI; RECONSTRUCTION; RECOVERY;
D O I
10.1038/s41598-024-54164-z
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In recent years, a variety of deep learning networks for cardiac MRI (CMR) segmentation have been developed and analyzed. However, nearly all of them are focused on cine CMR under breathold. In this work, accuracy of deep learning methods is assessed for volumetric analysis (via segmentation) of the left ventricle in real-time free-breathing CMR at rest and under exercise stress. Data from healthy volunteers (n = 15) for cine and real-time free-breathing CMR at rest and under exercise stress were analyzed retrospectively. Exercise stress was performed using an ergometer in the supine position. Segmentations of two deep learning methods, a commercially available technique (comDL) and an openly available network (nnU-Net), were compared to a reference model created via the manual correction of segmentations obtained with comDL. Segmentations of left ventricular endocardium (LV), left ventricular myocardium (MYO), and right ventricle (RV) are compared for both end-systolic and end-diastolic phases and analyzed with Dice's coefficient. The volumetric analysis includes the cardiac function parameters LV end-diastolic volume (EDV), LV end-systolic volume (ESV), and LV ejection fraction (EF), evaluated with respect to both absolute and relative differences. For cine CMR, nnU-Net and comDL achieve Dice's coefficients above 0.95 for LV and 0.9 for MYO, and RV. For real-time CMR, the accuracy of nnU-Net exceeds that of comDL overall. For real-time CMR at rest, nnU-Net achieves Dice's coefficients of 0.94 for LV, 0.89 for MYO, and 0.90 for RV and the mean absolute differences between nnU-Net and the reference are 2.9 mL for EDV, 3.5 mL for ESV, and 2.6% for EF. For real-time CMR under exercise stress, nnU-Net achieves Dice's coefficients of 0.92 for LV, 0.85 for MYO, and 0.83 for RV and the mean absolute differences between nnU-Net and reference are 11.4 mL for EDV, 2.9 mL for ESV, and 3.6% for EF. Deep learning methods designed or trained for cine CMR segmentation can perform well on real-time CMR. For real-time free-breathing CMR at rest, the performance of deep learning methods is comparable to inter-observer variability in cine CMR and is usable for fully automatic segmentation. For real-time CMR under exercise stress, the performance of nnU-Net could promise a higher degree of automation in the future.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Highly accelerated free-breathing real-time phase contrast cardiovascular MRI via complex-difference deep learning
    Haji-Valizadeh, Hassan
    Guo, Rui
    Kucukseymen, Selcuk
    Paskavitz, Amanda
    Cai, Xiaoying
    Rodriguez, Jennifer
    Pierce, Patrick
    Goddu, Beth
    Kim, Daniel
    Manning, Warren
    Nezafat, Reza
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (02) : 804 - 819
  • [32] Real-time imaging in electrophysiology: from intra-cardiac echo to real-time magnetic resonance imaging
    Akoum, Nazem
    Marrouche, Nassir F.
    EUROPACE, 2009, 11 (05): : 539 - 540
  • [33] Highly Accelerated Real-Time Free-Breathing Cine CMR for Patients With a Cardiac Implantable Electronic Device
    Hong, Sungtak
    Hong, KyungPyo
    Culver, Austin E.
    Pathrose, Ashitha
    Allen, Bradley D.
    Wilcox, Jane E.
    Lee, Daniel C.
    Kim, Daniel
    ACADEMIC RADIOLOGY, 2021, 28 (12) : 1779 - 1786
  • [34] Imaging of arrhythmia: Real-time cardiac magnetic resonance imaging in atrial fibrillation
    Laubrock, Kerstin
    von Loesch, Thassilo
    Steinmetz, Michael
    Lotz, Joachim
    Frahm, Jens
    Uecker, Martin
    Unterberg-Buchwald, Christina
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2022, 9
  • [35] Real-Time Exercise Cardiac Magnetic Resonance Imaging in Tetralogy of Fallot A Tool for Revisiting a Clinical Conundrum
    Pushparajah, Kuberan
    Duong, Phuoc
    CIRCULATION-CARDIOVASCULAR IMAGING, 2021, 14 (08)
  • [36] Right ventricular fatigue developing during endurance exercise: a real-time exercise cardiac magnetic resonance imaging study
    Claessen, Guido
    Claus, Piet
    Ghysels, Stefan
    Vermeersch, Pieter
    Dymarkowski, Steven
    La Gerche, Andre
    Heidbuchel, Hein
    ACTA CARDIOLOGICA, 2014, 69 (01) : 72 - 72
  • [37] New real-time interactive cardiac magnetic resonance imaging system
    Yang, P
    Kerr, A
    Liu, A
    Liang, DH
    Hardy, C
    Meyer, C
    Macovski, A
    Pauly, J
    Hu, B
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 3A - 4A
  • [38] Automatic segmentation of vocal tract articulators in real-time magnetic resonance imaging
    Ribeiro, Vinicius
    Isaieva, Karyna
    Leclere, Justine
    Felblinger, Jacques
    Vuissoz, Pierre-Andre
    Laprie, Yves
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 243
  • [39] Cardiac catheter ablation under real-time magnetic resonance guidance
    Nordbeck, Peter
    Beer, Meinrad
    Koestler, Herbert
    Ladd, Mark E.
    Quick, Harald H.
    Bauer, Wolfgang R.
    Ritter, Oliver
    EUROPEAN HEART JOURNAL, 2012, 33 (15) : 1977 - 1977
  • [40] Biventricular volumetric assessment of cardiac function by a novel cardiac magnetic resonance technique during real-time strenuous exercise
    Claessen, Guido
    La Gerche, Andre
    Van De Bruaene, Alexander
    Dymarkowski, Steven
    Gewillig, Marc
    Claus, Piet
    Heidbuchel, Hein
    ACTA CARDIOLOGICA, 2012, 67 (01) : 137 - 137