Measurement of energy and directional distribution of neutron ambient dose equivalent for the 7Li(p,n)7Be reaction

被引:0
|
作者
Roy, A. S. [1 ,2 ]
Banerjee, K. [2 ,3 ]
Roy, Pratap [2 ,3 ]
Shil, R. [4 ]
Ravishankar, R. [1 ]
Datta, R. [2 ,5 ]
Sen, A. [2 ,3 ]
Manna, S. [2 ,3 ]
Ghosh, T. K. [2 ,3 ]
Mukherjee, G. [2 ,3 ]
Rana, T. K. [2 ,3 ]
Kundu, S. [2 ,3 ]
Nayak, S. S. [2 ,3 ]
Pandey, R. [3 ]
Paul, D. [2 ,3 ]
Atreya, K. [2 ,3 ]
Basu, S. [2 ,3 ]
Mukhopadhyay, S. [2 ,3 ]
Pandit, Deepak [2 ,3 ]
Kulkarni, M. S. [1 ,2 ]
Bhattacharya, C. [2 ,3 ]
机构
[1] Bhabha Atom Res Ctr, Hlth Phys Div, Mumbai 400085, India
[2] Homi Bhabha Natl Inst, Training Sch Complex, Anushakti Nagar, Mumbai 400094, India
[3] Variable Energy Cyclotron Ctr, 1-AF Bidhannagar, Kolkata 700064, India
[4] Visva Bharati Univ, St iniketan, Bolpur 731235, West Bengal, India
[5] Bhabha Atom Res Ctr, RP&AD, Mumbai 400085, India
关键词
Liquid scintillator detector; Neutron energy spectra; Ambient dose equivalent; Time of Flight; ACCELERATOR-BASED BNCT; NEAR-THRESHOLD; LI-7(P; N)BE-7; REACTION; CROSS-SECTIONS; PROTON ENERGY; TARGET; THICK; SCINTILLATOR; DOSIMETRY; SPECTRA;
D O I
10.1016/j.apradiso.2023.111140
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Double differential neutron fluence distributions were measured in the 7Li(p,n)7Be reaction for proton beam energies 7, 9 and 12 MeV. Seven liquid scintillator based detectors were employed to measure neutron fluence distributions using the Time of Flight technique. Neutron ambient dose equivalents were determined from the measured fluence distribution using ICRP (International Commission on Radiological Protection) recommended fluence to dose equivalent conversion coefficients. Neutron dose equivalents were also measured using a conventional BF3 detector based REM counter. Ambient dose equivalent measured by the REM counter is found to be in agreement with that determined from the neutron fluence spectra within their uncertainties. Angular distributions of the ambient dose equivalents were also determined from the measured fluence distributions at different angles.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] MEASUREMENTS OF NEUTRON ENERGY SPECTRA FROM 7Li(p, n)7Be REACTION WITH BONNER SPHERE SPECTROMETER, NESTED NEUTRON SPECTROMETER AND ROSPEC
    Atanackovic, J.
    Matysiak, W.
    Witharana, S.
    Dubeau, J.
    Waker, A. J.
    RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 221 - 224
  • [22] Evaluation of target photon dose mixed in mono-energetic neutron fields using 7Li(p,n)7Be reaction
    Tanimura, Y.
    Tsutsumi, M.
    Saegusa, J.
    Shikaze, Y.
    Yoshizawa, M.
    RADIATION MEASUREMENTS, 2010, 45 (10) : 1163 - 1166
  • [23] Optimization of a neutron production target and beam shaping assembly based on the 7Li(p,n)7Be reaction
    Burlon, AA
    Kreiner, AJ
    Valda, AA
    Minsky, D
    Somacal, H
    Debray, ME
    Kesque, JM
    Stoliar, P
    Davidson, J
    Davidson, M
    Ozafrán, MJ
    Schuff, JA
    Vázquez, ME
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 229 - 234
  • [24] Neutron Source for Boron-Neutron-Capture Therapy Based on the Reaction 7Li(p, n)7Be Near Threshold
    O. E. Kononov
    V. N. Kononov
    N. A. Solov'ev
    Atomic Energy, 2003, 94 : 417 - 420
  • [25] Neutron source for boron-neutron-capture therapy based on the reaction 7Li(p, n)7Be near threshold
    Kononov, OE
    Kononov, VN
    Solov'ev, NA
    ATOMIC ENERGY, 2003, 94 (06) : 417 - 420
  • [26] Optimized therapeutic neutron beam for accelerator-based BNCT by analyzing the neutron angular distribution from 7Li(p,n)7Be reaction
    Kim, Kyung-O
    Kim, Jong Kyung
    Kim, Soon Young
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : 1173 - 1179
  • [27] New method to evaluate the 7Li(p,n)7Be reaction near threshold
    Herrera, Maria S.
    Moreno, Gustavo A.
    Kreiner, Andres J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 349 : 64 - 71
  • [28] Study on the optimal incident proton energy of 7Li(p, n)7Be neutron source for boron neutron capture therapy
    Yi-Nan Zhu
    Zuo-Kang Lin
    Hai-Yan Yu
    Ye Dai
    Zhi-Min Dai
    Xiao-Han Yu
    NuclearScienceandTechniques, 2024, 35 (03) : 172 - 182
  • [29] Study on the optimal incident proton energy of 7Li(p, n)7Be neutron source for boron neutron capture therapy
    Zhu, Yi-Nan
    Lin, Zuo-Kang
    Yu, Hai-Yan
    Dai, Ye
    Dai, Zhi-Min
    Yu, Xiao-Han
    NUCLEAR SCIENCE AND TECHNIQUES, 2024, 35 (03)
  • [30] Investigations of using near-threshold 7Li(p,n) 7Be reaction for NCT based on in-phantom dose distribution
    Kononov, O
    Kononov, V
    Korobeynikov, V
    Ognev, S
    Chu, W
    Silvestrov, G
    Soloviev, N
    Taskaev, S
    Zhitnik, A
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 241 - 246