The calibration of transfer standards for the measurement of 222Rn at NIM

被引:0
|
作者
Sun, Changhao [1 ]
Fan, Zihao [1 ,2 ]
Yang, Zhijie [1 ]
Liu, Meiling [1 ]
Liang, Juncheng [1 ]
Liu, Haoran [1 ]
Zhang, Jian [1 ]
Qiu, Xiangping [1 ]
机构
[1] Natl Inst Metrol, Div Ionizing Radiat Metrol, Beijing 100029, Peoples R China
[2] China Inst Atom Energy, Beijing 102413, Peoples R China
关键词
Radon; Calibration; Transfer standard; Gaseous 222 Rn standard source;
D O I
10.1016/j.apradiso.2023.110971
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A high-purity germanium (HPGe) gamma-ray spectrometer and an Alpha-GUARD radon monitor are the activity and activity concentration transfer standards of 222Rn, respectively. The gaseous 222Rn standard source traceable to the NIM's absolute standardization apparatus of 222Rn was developed for calibrating these transfer standards. The calibration results of HPGe detector at three different distances show that the uncertainties of experimental efficiency are less than 0.77% (k = 1). Meanwhile, the Monte Carlo (MC) simulation was carried out at wider distances range for the HPGe calibration as well, and the deviation at same three distances between experiments and simulations results is within & PLUSMN;3.0%. The advantage of calibration using MC simulation and the possible reasons for the deviation were discussed in detail in this article. In addition, a reference activity concentration environment based on the gaseous 222Rn standard source was also developed to calibrate the radon monitor, and the typical uncertainty for calibration factor of Alpha-GUARD radon monitor could be reduced to 1.9% (k = 1).
引用
收藏
页数:6
相关论文
共 50 条
  • [41] ERRORS IN MEASUREMENTS OF 222RN IN METHANE AND CARBON DIOXIDE USING SCINTILLATION CELLS CALIBRATED FOR 222RN IN AIR
    Jenkins, Phillip H.
    Burkhart, James F.
    Camley, Robert E.
    HEALTH PHYSICS, 2014, 106 (03): : 397 - 404
  • [42] Measurement of radon (222Rn) and thoron (220RN) concentration with a single scintillation cell
    Machaj, Bronislaw
    Urbanski, Piotr
    Bartak, Jakub
    NUKLEONIKA, 2007, 52 (04) : 167 - 171
  • [43] A novel application for 222Rn emanation standards: Radon-cryptophane host chemistry
    Laureano-Perez, L.
    Colle, R.
    Jacobson, D. R.
    Fitzgerald, R.
    Khan, N. S.
    Dmochowski, I. J.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 1997 - 2001
  • [44] STANDARDS, CALIBRATION AND QUALITY ASSURANCE OF RN-222 MEASUREMENTS IN SWEDEN
    FALK, R
    HAGBERG, N
    MJONES, L
    MORE, H
    NYBLOM, L
    SWEDJEMARK, GA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 339 (1-2): : 254 - 263
  • [45] Estimation of 222Rn flux from ground surface based on the variation analysis of 222Rn concentration in a closed chamber
    Koarashi, J
    Amano, H
    Andoh, M
    Iida, T
    RADIATION PROTECTION DOSIMETRY, 2000, 87 (02) : 121 - 131
  • [46] Calibration of LR-115 for 222Rn monitoring taking into account the plateout effect
    Da Silva, AAR
    Yoshimura, EM
    RADIATION PROTECTION DOSIMETRY, 2003, 103 (04) : 367 - 370
  • [47] Test of a northwards-decreasing 222Rn source term by comparison of modelled and observed atmospheric 222Rn concentrations
    Robertson, LB
    Stevenson, DS
    Conen, F
    TELLUS SERIES B-CHEMICAL AND PHYSICAL METEOROLOGY, 2005, 57 (02): : 116 - 123
  • [48] Design and Tests of a Detector for 222Rn in Soil-gas Measurements based on 222Rn Absorbing Scintillating Polymers
    Mitev, Krasimir K.
    Tsankov, Ludmil T.
    Mitev, Mityo G.
    Dutsov, Chavdar C.
    Georgiev, Strahil B.
    Kolev, Srebrin T.
    Markov, Nikolay M.
    Todorov, Todor Hr.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [49] Concentrations of 222Rn and 220Rn in indoor air
    Vaupotic, Janja
    Celikovic, Igor
    Smrekar, Natasa
    Zunic, Zora S.
    Kobal, Ivan
    ACTA CHIMICA SLOVENICA, 2008, 55 (01) : 160 - 165
  • [50] Preparation of gaseous CRMs from the primary system for 222Rn activity measurement
    Kim, B. J.
    Kim, B. C.
    Lee, K. B.
    Lee, J. M.
    Park, T. S.
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 122 - 125