Stiffness and strength evaluation of prestressed timber beam with unbonded steel Strand and reinforced concrete Beam-Column joint

被引:0
|
作者
Shirayama, Takashi [1 ,2 ]
Satou, Nozomi [1 ]
Tokutake, Shigetaka [1 ]
机构
[1] Sumitomo Mitsui Construct Co Ltd, Bldg Construct Div, Tokyo, Japan
[2] Sumitomo Mitsui Construct Co Ltd, Bldg Construct Div, 2-1-6 Tsukuda,Chuo ku, Tokyo 1040051, Japan
关键词
moment-resisting connection; post-tensioned glued laminated timber; prestress; reinforced concrete beam-column joint; unbonded steel Strand; PERFORMANCE; CONNECTIONS; BEHAVIOR;
D O I
10.1002/2475-8876.12342
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The deformation behavior of prestressed timber beams after a gap opens at the beam-column interface is evaluated in this study using the compressive stress distribution along the beam length. The correlation between moment at the beam end and beam deformation is studied for three types of specimens. The evaluation results indicate that the prediction is in good agreement with the experimental results up to the proportional limit of the material. In addition, the bending ultimate strength calculated using the compressive stress distribution at the beam end, which is obtained from the compressive stress-strain relationship, is also verified with the values of moments in the experiment. Finally, an alternative elastic element model with a quadrilinear rigid-plastic spring at the element end was proposed.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Deformations of reinforced-concrete beam-column joint assemblies
    Lee, Jung-Yoon
    Kim, Changhyuk
    Park, Jongwook
    MAGAZINE OF CONCRETE RESEARCH, 2020, 72 (13) : 649 - 669
  • [22] Analysis of shear strength for reinforced concrete beam-column joints
    Zhu, Hongping
    Dai, Yunjie
    Gao, Fei
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2013, 41 (07): : 1 - 4
  • [23] Shear strength within reinforced concrete beam-column joints
    Bolton Inst of Higher Education
    Struct Eng, 4 (53-57):
  • [24] Shear behavior of exterior reinforced concrete column-steel beam beam-column connections
    Shen, Hong-Xia
    Gu, Qiang
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2010, 42 (SUPPL. 1): : 154 - 161
  • [26] Shear strength of steel fibre reinforced prestressed concrete beam
    Langsford, R. P.
    Lloyd, N.
    Sarker, P. K.
    INNOVATIONS IN STRUCTURAL ENGINEERING AND CONSTRUCTION, VOLS 1 AND 2, 2008, : 441 - 446
  • [27] Experimental study on bonded and unbonded prestressed precast concrete beam-column substructures under penultimate column removal
    Shi, Hai-Rong
    Zeng, Bin
    Yu, Jun
    Wang, Chun-Lin
    ENGINEERING STRUCTURES, 2025, 323
  • [28] Reinforced concrete beam-column joint strengthened with carbon fiber reinforced polymer
    Lee, W. T.
    Chiou, Y. J.
    Shih, M. H.
    COMPOSITE STRUCTURES, 2010, 92 (01) : 48 - 60
  • [29] Seismic Performance of the King Cross Steel Profile in interior Reinforced Concrete Beam-column Joint
    Kadarningsih, Rahmani
    Satyarno, Iman
    Muslikh
    Triwiyono, Andreas
    JOURNAL OF PHYSICAL SCIENCE, 2018, 29 : 99 - 115
  • [30] Analysis and design of reinforced concrete beam-column joint using King Cross steel profile
    Kadarningsih, Rahmani
    Satyarno, Iman
    Muslikh
    Triwiyono, Andreas
    3RD INTERNATIONAL CONFERENCE ON SUSTAINABLE CIVIL ENGINEERING STRUCTURES AND CONSTRUCTION MATERIALS - SUSTAINABLE STRUCTURES FOR FUTURE GENERATIONS, 2017, 171 : 948 - 956