Numerical Analysis of Air Flow in an Industrial Refrigeration System and Its Effect on Energy Consumption

被引:4
|
作者
Aktas, Mustafa [1 ]
Karyeyen, Serhat [1 ]
Okur, Alperen [2 ]
Erdogmus, Fatma Nur [3 ]
机构
[1] Gazi Univ, Energy Syst Engn, Ankara, Turkiye
[2] Gazi Univ, Nat & Appl Sci Inst, Ankara, Turkiye
[3] Nurdil Refrigerat Inc, Ankara, Turkiye
来源
GAZI UNIVERSITY JOURNAL OF SCIENCE | 2023年 / 36卷 / 03期
关键词
Refrigeration; Energy efficiency; Display cabinet; CFD; CURTAINS; PATTERNS;
D O I
10.35378/gujs.1091383
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Refrigerated display cabinets as a type of cooling system is preferable commonly in food shops and grocery store to prevent foods from warm air. They do not have much more efficient compared to the cabinets with glass doors because of the interactions between air curtain. This paper presents experimental and numerical methods to seek energy performance of the horizontal refrigerated display cabinets in terms of design parameters. Two geometry with/without airfoil were designed and evaluated the effects of discharge velocity to create more efficient air curtain. 2D Computational Fluid Dynamics (CFD) model was performed to assess the effect of discharge flow on the cooling load performance of the horizontal display cabinet. The results showed that the airfoil design has increased the efficiency of the air curtain with achieving a more effective air curtain, resulted in mitigation of the ambient warm air infiltration into the cabinet. The return air temperature of the cabinet with airfoil decreased from 272.45 K to 270.62 K compared to the one without airfoil due to more effective air curtain. In this way, the cooling capacity of the refrigeration system has been decreased by 3.82% with airfoil usage. It is also concluded that the air temperature inside the cabinet and the cooling capacity have been decreased by 3.5 degrees C and 2.82%, respectively when Case 7 for used the new type airfoil and Case 1 with the same air velocity are compared.
引用
收藏
页码:1259 / 1275
页数:17
相关论文
共 50 条
  • [41] Current consumption monitoring and analysis system for energy management improvement in an industrial complex
    Ionescu, L. M.
    Mazare, A.
    Lita, A. I.
    Visan, D.
    Serban, G.
    Belu, N.
    Sanmarghitan, A.
    Goeller, T.
    Balauta, S.
    2017 IEEE 23RD INTERNATIONAL SYMPOSIUM FOR DESIGN AND TECHNOLOGY IN ELECTRONIC PACKAGING (SIITME), 2017, : 286 - 291
  • [42] Survey and Analysis of Energy System's Energy Consumption Focused on Typical Industrial Buildings in Shenyang
    Wang, Hongwei
    Liu, Ying
    Wang, Baoling
    Yu, Lingyan
    RENEWABLE AND SUSTAINABLE ENERGY II, PTS 1-4, 2012, 512-515 : 2914 - 2917
  • [43] COLD THERMAL ENERGY STORAGE INTEGRATION IN A LARGE INDUSTRIAL REFRIGERATION SYSTEM
    Selvnes, Hakon
    Hafner, Armin
    Kauko, Hanne
    13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 1231 - 1238
  • [44] Performance analysis of static ice refrigeration air conditioning system driven by household distributed photovoltaic energy system
    Xu, Yongfeng
    Ma, Xun
    Hassanien, Reda Hassanien Emam
    Luo, Xi
    Li, Guoliang
    Li, Ming
    SOLAR ENERGY, 2017, 158 : 147 - 160
  • [45] Refrigeration Efficient Refrigeration for the Industry A two-stage system ensures quality and reduces energy consumption
    Lukas, Detlev A.
    FLEISCHWIRTSCHAFT, 2011, 91 (04): : 51 - 52
  • [46] Numerical procedure for predicting annual energy consumption of the under-floor air distribution system
    Xu, HT
    Niu, JL
    ENERGY AND BUILDINGS, 2006, 38 (06) : 641 - 647
  • [47] The effect of "energy of scale" on the energy consumption in different industrial sectors
    Binderbauer, Paul Josef
    Woegerbauer, Matthias
    Nagovnak, Peter
    Kienberger, Thomas
    SUSTAINABLE PRODUCTION AND CONSUMPTION, 2023, 41 : 75 - 87
  • [48] Characteristics of office lighting energy consumption and its impact on air conditioning energy consumption
    Song S.
    Long J.
    Jiang H.
    Ran B.
    Yao L.
    Energy and Built Environment, 2024, 5 (04): : 529 - 543
  • [49] A numerical investigation of the compressible flow in the ejector of a vapour ejector refrigeration system
    Megalingam, A.
    Babu, V.
    PROGRESS IN COMPUTATIONAL FLUID DYNAMICS, 2020, 20 (01): : 29 - 39
  • [50] EVOLUTION OF THE TRANSPORT-SYSTEM AND ITS EFFECT ON ENERGY-CONSUMPTION
    SCIARRONE, G
    APPLIED ENERGY, 1990, 36 (1-2) : 29 - 34