A Multi-Parameter Fusion Method for Cuffless Continuous Blood Pressure Estimation Based on Electrocardiogram and Photoplethysmogram

被引:3
|
作者
Ma, Gang [1 ,2 ]
Zhang, Jie [2 ]
Liu, Jing [3 ]
Wang, Lirong [2 ,3 ]
Yu, Yong [2 ]
机构
[1] Univ Sci & Technol China, Sch Biomed Engn, Div Life Sci & Med, Hefei 230026, Peoples R China
[2] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Suzhou 215163, Peoples R China
[3] Soochow Univ, Sch Elect & Informat Technol, Suzhou 215031, Peoples R China
基金
中国国家自然科学基金;
关键词
blood pressure; wearable device; feature extraction; GCMI; ARTERIAL STIFFNESS; FEATURE-SELECTION; VOLUME PULSE; TIME; HYPERTENSION; HEALTH;
D O I
10.3390/mi14040804
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Blood pressure (BP) is an essential physiological indicator to identify and determine health status. Compared with the isolated BP measurement conducted by traditional cuff approaches, cuffless BP monitoring can reflect the dynamic changes in BP values and is more helpful to evaluate the effectiveness of BP control. In this paper, we designed a wearable device for continuous physiological signal acquisition. Based on the collected electrocardiogram (ECG) and photoplethysmogram (PPG), we proposed a multi-parameter fusion method for noninvasive BP estimation. An amount of 25 features were extracted from processed waveforms and Gaussian copula mutual information (MI) was introduced to reduce feature redundancy. After feature selection, random forest (RF) was trained to realize systolic BP (SBP) and diastolic BP (DBP) estimation. Moreover, we used the records in public MIMIC-III as the training set and private data as the testing set to avoid data leakage. The mean absolute error (MAE) and standard deviation (STD) for SBP and DBP were reduced from 9.12 +/- 9.83 mmHg and 8.31 +/- 9.23 mmHg to 7.93 +/- 9.12 mmHg and 7.63 +/- 8.61 mmHg by feature selection. After calibration, the MAE was further reduced to 5.21 mmHg and 4.15 mmHg. The result showed that MI has great potential in feature selection during BP prediction and the proposed multi-parameter fusion method can be used for long-term BP monitoring.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Photoplethysmogram Intensity Ratio: A Potential Indicator for Improving the Accuracy of PTT-Based Cuffless Blood Pressure Estimation
    Ding, Xiao-Rong
    Zhang, Yuan-Ting
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 398 - 401
  • [22] State of Charge Estimation Method of Lead-Acid Battery Based on Multi-parameter Fusion
    Yu, Yuan
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT SYSTEMS AND INFORMATICS 2019, 2020, 1058 : 1080 - 1086
  • [23] Generalized Deep Neural Network Model for Cuffless Blood Pressure Estimation with Photoplethysmogram Signal Only
    Hsu, Yan-Cheng
    Li, Yung-Hui
    Chang, Ching-Chun
    Harfiya, Latifa Nabila
    SENSORS, 2020, 20 (19) : 1 - 18
  • [24] Sparse Representation of Photoplethysmogram Using K-SVD for Cuffless Estimation of Arterial Blood Pressure
    Bose, Sree Niranjanaa S.
    Kandaswamy, A.
    2017 4TH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING AND COMMUNICATION SYSTEMS (ICACCS), 2017,
  • [25] Photoplethysmography-based cuffless blood pressure estimation: an image encoding and fusion approach
    Liu, Yinsong
    Yu, Junsheng
    Mou, Hanlin
    PHYSIOLOGICAL MEASUREMENT, 2023, 44 (12)
  • [26] A chest-based continuous cuffless blood pressure method: Estimation and evaluation using multiple body sensors
    Heydari, Fatemeh
    Ebrahim, Malikeh P.
    Redoute, Jean-Michel
    Joe, Keith
    Walker, Katie
    Yuce, Mehmet Rasit
    INFORMATION FUSION, 2020, 54 : 119 - 127
  • [27] The Wavelet Transform of Pulse Wave and Electrocardiogram Improves Accuracy of Blood Pressure Estimation in Cuffless Blood Pressure Measurement
    Yamanaka, Syunsuke
    Morikawa, Koji
    Yamamura, Osamu
    Morita, Hiroshi
    Huh, Ji Young
    CIRCULATION, 2016, 134
  • [28] Study of cuffless blood pressure estimation method based on multiple physiological parameters
    Zhang, Yiming
    Zhou, Congcong
    Huang, Zhongyi
    Ye, Xuesong
    PHYSIOLOGICAL MEASUREMENT, 2021, 42 (05)
  • [29] Investigation of Data Leakage in Deep-Learning-Based Blood Pressure Estimation Using Photoplethysmogram/Electrocardiogram
    Yoshizawa, Rikuto
    Yamamoto, Kohei
    Ohtsuki, Tomoaki
    IEEE SENSORS JOURNAL, 2023, 23 (12) : 13311 - 13318
  • [30] The Wavelet Transform of Pulse Wave and Electrocardiogram Improves Accuracy of Blood Pressure Estimation in Cuffless Blood Pressure Measurement
    Yamanaka, Syunsuke
    Morikawa, Koji
    Yamamura, Osamu
    Morita, Hiroshi
    Huh, Ji Young
    CIRCULATION, 2016, 134