In vitro temperature changes in the pulp chamber caused by laser and Quadwave LED-light curing units

被引:6
|
作者
Maucoski, Cristiane [1 ,2 ]
Price, Richard Bengt [1 ]
Arrais, Cesar Augusto Galvao [2 ]
Sullivan, Braden [1 ]
机构
[1] Dalhousie Univ, Dept Dent Clin Sci, Halifax, NS B3H 4R2, Canada
[2] Univ Estadual Ponta Grossa, Dept Restorat Dent, 4748 Gen Carlos Cavalcanti Ave, BR-84051130 Ponta Grossa, PR, Brazil
关键词
Laser; Light-emitting diode; Dental curing lights; Temperature; ANESTHETIZED HUMAN PULP; HEAT; RISE; POLYMERIZATION; EXPOSURE; MICROCIRCULATION; INCREASE; GINGIVA; DENTIN; DIODE;
D O I
10.1007/s10266-022-00780-y
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The study evaluated the pulp temperature (PT) increase in Class I and V preparations when exposed to the Monet Laser (for 1 and 3 s), the PinkWave (for 3 and 10 s), the Valo Grand (for 3 and 10 s), the PowerCure, (for 3 and 10 s) and the SmartLite Pro (for 10 s). Non-retentive Class I and Class V cavities were prepared in one molar fixed in an acrylic plate and positioned in a warm water bath. The PT baseline was kept at 32 & DEG;C to simulate physiological conditions. Two T-type thermocouples were inserted through the roots into the pulp chamber in two positions: close to the pulp horn and the buccal wall close to the Class V cavity. The water flow was adjusted to 0.026 mL/min, and real-time temperature data were collected every 0.5 s. PT measurements were made with the tip of the LCU 0 and 6 mm away from the tooth surface. The radiant exitance (mW/cm(2)) and radiant exposure (J/cm(2)) were calculated. One-way ANOVA compared the effect of the pulpal flow, and & UDelta;T values were subjected to two-way ANOVA, followed by Scheffe's post hoc tests. The Monet Laser used for 3 s and the PinkWave used for 10 s produced the greatest PT rise in the Class I cavity. The simulated pulpal flow did not influence the PT rise. Overall, cavities exposed at the 0 mm distance had higher & UDelta;T values than groups at 6 mm distance. The placement of a rubber dam for Class V restorations may prevent positioning LCUs directly over the cavity, which may affect the rise in PT.
引用
收藏
页码:668 / 679
页数:12
相关论文
共 50 条
  • [41] Parameters Influencing Increase in Pulp Chamber Temperature with Light-curing Devices: Curing Lights and Pulpal Flow Rates (vol 35, pg 353, 2010)
    Park, S-H
    Roulet, J-F
    Heintze, S. D.
    OPERATIVE DENTISTRY, 2010, 35 (04) : 487 - 487
  • [42] Temperature changes and thermo-light polymerization efficacy of two LED curing lights and 445-nm diode laser on glass carbomer material
    Sesen Uslu Y.
    Ozveren N.
    Donmez N.
    Ulukapı H.
    Lasers in Dental Science, 2021, 5 (4) : 247 - 256
  • [43] Temperature change in pulp chamber of primary teeth during curing of coloured compomers: an in vitro study using pulpal blood microcirculation model
    Ertugrul, Ceylan Cagil
    Ertugrul, Ihsan Furkan
    PEERJ, 2019, 7
  • [44] Evaluation of Temperature Changes in the Pulp Chamber During Bulk-Fill Composite Polymerization: An In-Vitro Study
    Mollaoglu, Eda Yildiz
    Kaptan, Alper
    JOURNAL OF ADVANCED ORAL RESEARCH, 2022, 13 (02) : 207 - 215
  • [45] Temperature Changes in Primary and Permanent Teeth Dentine of Varying Thicknesses Following Irradiation by Two Light Curing Units
    Alfares, Reem
    Agha, Amani
    Labour, Obada
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (08)
  • [46] The Temperature Changes in the Pulp Chamber During Cavity Preparation with the Er:YAG Laser Using a Very Short Pulse
    Jukic Krmek, Silvana
    Miletic, Ivana
    Simeon, Paris
    Mehicic, Goranka Prpic
    Anic, Ivica
    Radisic, Berislav
    PHOTOMEDICINE AND LASER SURGERY, 2009, 27 (02) : 351 - 355
  • [47] Influence of Class V preparation on in vivo temperature rise in anesthetized human pulp during exposure to a Polywave® LED light curing unit
    Zarpellon, Driellen Christine
    Runnacles, Patricio
    Maucoski, Cristiane
    Gross, Dayane Jaqueline
    Coelho, Ulisses
    Rueggeberg, Frederick Allen
    Galvao Arrais, Cesar Augusto
    DENTAL MATERIALS, 2018, 34 (06) : 901 - 909
  • [48] Influence of Cavity Preparation, Light-curing Units, and Composite Filling on Intrapulpal Temperature Increase in an In Vitro Tooth Model
    Choi, S. H.
    Roulet, J. F.
    Heintze, S. D.
    Park, S. H.
    OPERATIVE DENTISTRY, 2014, 39 (05) : E195 - E205
  • [49] MEASUREMENT OF TEMPERATURE-CHANGES WITHIN THE PULP CHAMBER DUE TO EXPOSURE TO VISIBLE-LIGHT FROM SEVERAL POLYMERIZING LIGHT-SOURCES
    SHARKEY, SW
    MCCROSSON, J
    SMITH, GM
    JOURNAL OF DENTAL RESEARCH, 1987, 66 (04) : 876 - 876
  • [50] In vitro analysis of human tooth pulp chamber temperature after low-intensity laser therapy at different power outputs
    Mollo, Marcio de Alencar
    Frigo, Lucio
    Favero, Giovani Marino
    Brandao Lopes-Martins, Rodrigo Alvaro
    Brugnera Junior, Aldo
    LASERS IN MEDICAL SCIENCE, 2011, 26 (02) : 143 - 147