Stability Domain Analysis for Islanded Microgrid Considering N-1 Contingency

被引:1
|
作者
Lasheen, Ahmed [1 ]
Sindi, Hatem F. [2 ]
Shaaban, Mostafa F. [3 ]
Zeineldin, Hatem H. [1 ,4 ]
Hamad, Basil [4 ]
Al-Durra, Ahmed [4 ]
机构
[1] Cairo Univ, Fac Engn, Elect Power Engn Dept, Cairo 12613, Egypt
[2] King Abdulaziz Univ, Elect & Comp Engn Dept, Jeddah 21589, Saudi Arabia
[3] Amer Univ Sharjah, Elect Engn Dept, Sharjah, U Arab Emirates
[4] Khalifa Univ Sci & Technol, Adv Power & Energy Ctr, Abu Dhabi, U Arab Emirates
关键词
Microgrids; Stability criteria; Power system stability; Load modeling; Contingency management; Reactive power; Transient analysis; Domain of stability; N-1; contingency; inverter-based micro-grid; DG disconnection; network disconnection; DROOP;
D O I
10.1109/ACCESS.2023.3325626
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The most popular approach used in controlling inverter-based microgrids is the droop control technique, characterized by its plug-and-play capability and independence from communication requirements. The control parameters, at the top of which the active and reactive droop gains, mp and nq, respectively, have been recently studied, evaluating their impact on stability. Furthermore, the stability domain chart is plotted in the m(p,max)-n(q) plane identifying the stable range of the microgrid, enabling the microgrid operator to choose the desired stable operating point based on frequency, voltage, and power-sharing requirements. However, the microgrid is prone to abnormal conditions, such as network disconnection, distributed generator (DG) disconnection, and load disconnection, that also affect microgrid stability. Hence, this can have an impact on the stability domain and, consequently, the choice of droops for stable operation. Therefore, in this paper, several stability domain charts are proposed, considering all various contingencies. The proposed network disconnection, DG disconnection, and load disconnection domain charts have been combined to generate an overall stability domain chart considering N - 1 contingency. The proposed N - 1 contingency chart is of crucial importance in considering the microgrid stability for both normal and abnormal operations. N - 1 contingencies can be frequent in microgrid operation due to microgrid limited space and power nature. Hereby, the inclusion of their impact on microgrid stability provides better guidance for the tuning of the control parameters. Moreover, the proposed chart is tested and validated using time-domain simulations on MATLAB, considering different operating points. The simulation results highlight the significance of the stability domain chart for selecting the DG droop gains to maintain the microgrid stability considering N - 1 contingency. Further, real-time validation of the proposed domain of stability through OPAL-RT setup is analyzed to confirm the ability of practical controllers to respond to microgrid variations conditions in real-time operation.
引用
收藏
页码:115986 / 115997
页数:12
相关论文
共 50 条
  • [41] Photovoltaic Power Penetration Planning with Generator Output and Capacitor Adjustments Using PSO Considering N-1 Contingency
    Hlaing, Aye Mya Mya
    Ando, Sho
    Kawaura, Yuki
    Iwamoto, Shinichi
    2014 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (IEEE PES APPEEC), 2014,
  • [42] A Decoupled Adaptive Overcurrent Coordination Considering N-1 Contingency and Distributed Generation Using an Effective Evonorm Algorithm
    Shih, Meng Yen
    Conde, Arturo
    Guajardo, Luis Alonso Trujillo
    Guillen, Daniel
    Leonowicz, Zbigniew
    Zarraga, Francisco Roman Lezama
    Gonzalez, Jorge de Jesus Chan
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2024, 60 (04) : 5480 - 5489
  • [43] Parameter Stability Region Analysis of Islanded Microgrid Based on Bifurcation Theory
    Shuai, Zhikang
    Peng, Yelun
    Liu, Xuan
    Li, Zuyi
    Guerrero, Josep M.
    Shen, Z. John
    IEEE TRANSACTIONS ON SMART GRID, 2019, 10 (06) : 6580 - 6591
  • [44] Static Voltage Stability Analysis of an Islanded Microgrid Using Energy Function
    Neto, Joao A. S.
    Zambroni De Souza, A. C.
    De Lorenci, Eliane Valenca
    Mendes, Thais P.
    Dos Santos, Priscila M. D.
    Nascimento, Bruno De N.
    IEEE ACCESS, 2020, 8 : 201005 - 201014
  • [45] Feature-Reduced Stability Analysis of Islanded Photovoltaic Microgrid Inverters
    Prakash, A. Om
    Banu, R. Narmatha
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2022, 2022
  • [46] A technique for optimal shunt capacitor reallocation considering voltage stability in N-1 contingencies
    Ohtake, Hiroshi
    Kimura, Katsuyuki
    Iwamoto, Shinichi
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 2598 - +
  • [47] Adaptive harmonic-based protection coordination for inverter-dominated isolated microgrids considering N-1 contingency
    Sati, Talal Elemamali
    Azzouz, Maher A.
    Shaaban, Mostafa F.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 156
  • [48] Performance Index Analysis (PIA) for N-1 Contingency Transmission in 150 kV Electricity System
    Putri, Mellynda Dwi Marda
    Afandi, Arif Nur
    2019 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS AND INFORMATION ENGINEERING (ICEEIE), 2019, : 48 - 52
  • [49] A LSTM-based approach for detection of high impedance faults in hybrid microgrid with immunity against weather intermittency and N-1 contingency
    Rameshrao, Awagan Goyal
    Koley, Ebha
    Ghosh, Subhojit
    RENEWABLE ENERGY, 2022, 198 : 75 - 90
  • [50] New techniques for measuring impedance characteristics of an islanded microgrid based on stability analysis
    Xi'an Jiaotong University, Xi'an
    710049, China
    Diangong Jishu Xuebao, 22 (153-162):