Development of a sensitive LC-APCI-MS/MS method for simultaneous determination of eleven nitrosamines in valsartan and irbesartan with a simple extraction approach

被引:5
|
作者
Mavis, Murat Emrah [1 ]
Gursu, Gokce Goksu [1 ]
Cagatay, Nese Ular [1 ]
机构
[1] Sem Laboratuar Cihazlari Pazarlama San Ve Tic Inc, R&D Ctr, TR-34746 Istanbul, Turkiye
关键词
N-nitrosamines; Sartans; Liquid chromatography; Mass spectrometry; Simultaneous determination;
D O I
10.1016/j.jchromb.2023.123593
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Nitrosamines (NAs) are potent genotoxic agents (GAs) in several animal species, and some are classified as probable or possible human carcinogens by the International Agency for Research on Cancer (IARC). In July 2018, angiotensin II receptor blockers (ARBs) which are used to treat high blood pressure have been recalled owing to contamination with NAs. In this study, a simple and sensitive method for the determination of eleven NAs in a single analysis was developed, using atmospheric pressure chemical ionisation source coupled liquid chromatography tandem mass spectrometer (LC-APCI-MS/MS). By performing the 17 min-run in dynamic multiple reaction monitoring (dMRM) mode, eleven NAs were separated on a Poroshell HPH C18 (4.6 x 150 mm, 2.7 mu m) column with gradient elution implementing mobile phase A consisting of 0.2 % formic acid in water and mobile phase B consisting of methanol. The developed analytical method was successfully applied in both active pharmaceutical ingredients (APIs) and finished products (FPs) of valsartan and irbesartan with straightforward and effective extraction procedures. Good linearity with a correlation coefficient (R2) > 0.996 was achieved over the concentration in a range of 0.5-50 ng/mL. The limits of detection (LODs) ranged in 0.001-0.008 ppm and limits of quantitation (LOQs) ranged in 0.008-0.05 ppm of the method fulfilled thresholds of US Food and Drug Administration (US-FDA) and European Medicines Agency (EMA) for testing of GAs in valsartan and irbesartan. The accuracy of the proposed method ranged from 73.1 % to 115.2 % for APIs and the relative standard deviation (RSD %) was <= 11.3 while these validation parameters were in the range of 80.2-128.5 % and <= 10.6 for FPs, respectively.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Optimization and Validation of a Method using SPE and LC-APCI-MS/MS for Determination of Pharmaceuticals in Surface and Public Supply Water
    Cardoso, Liziane V.
    Tomasini, Debora
    Sampaio, Maicon R. F.
    Caldas, Sergiane S.
    Kleemann, Natiele
    Primel, Ednei G.
    Goncalves, Fabio F.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2011, 22 (10) : 1944 - 1952
  • [22] Simultaneous Determination of 15 Sulfonate Ester Impurities in Phentolamine Mesylate, Amlodipine Besylate, and Tosufloxacin Tosylate by LC-APCI-MS/MS
    Jin, Bo
    Guo, Kaijing
    Zhang, Tingting
    Li, Tong
    Ma, Chen
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2019, 2019
  • [23] Determination of diclofenac sodium, flufenamic acid, indomethacin and ketoprofen by LC-APCI-MS
    Abdel-Hamid, ME
    Novotny, L
    Hamza, H
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 24 (04) : 587 - 594
  • [24] Simultaneous quantification of vinblastine and desacetylvinblastine concentrations in canine plasma and urine samples using LC-APCI-MS/MS
    Achanta, Satyanarayana
    Ngo, Minh
    Veitenheimer, Allison
    Maxwell, Lara K.
    Wagner, Jarrad R.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 913 : 147 - 154
  • [25] Matrix effect in LC-ESI-MS and LC-APCI-MS with off-line and on-line extraction procedures
    Souverain, S
    Rudaz, S
    Veuthey, JL
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1058 (1-2) : 61 - 66
  • [26] Simultaneous determination of triptolide and tripdiolide in extract of Tripterygium wilfordii Hook. f. by LC-APCI-MS
    OuYang, Xiao-kun
    Jin, Mi-cong
    He, Chao-hong
    CHROMATOGRAPHIA, 2007, 65 (5-6) : 373 - 375
  • [27] On-Line SPE Coupled with LC-APCI-MS for the Determination of Trace Explosives in Water
    Sun, Qian
    Chen, Zuliang
    Yuan, Dongxing
    Yu, Chang-Ping
    Mallavarapu, Megharaj
    Naidu, Ravendra
    CHROMATOGRAPHIA, 2011, 73 (7-8) : 631 - 637
  • [28] A simple and sensitive method for the determination of tranylcypromine in plasma with LC-MS/MS
    Kirchherr, H
    Kühn-Velten, WN
    PHARMACOPSYCHIATRY, 2005, 38 (01) : 55 - 55
  • [29] A Simple and Sensitive LC-MS/MS Method for the Simultaneous Determination of Cyclophosphamide and Dexorubicin Concentrations in Human Plasma
    He, Wenxuan
    Martin, Jennifer H.
    Shaw, Paul N.
    Lu, Xianyong
    Walpole, Euan T.
    Dimeski, Goce
    CURRENT PHARMACEUTICAL ANALYSIS, 2018, 14 (01) : 53 - 59
  • [30] Determination of azaarenes in oils using the LC-APCI-MS/MS technique: New environmental toxicant in food oils
    Szterk, Arkadiusz
    Roszko, Marek
    Cybulski, Adam
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (21) : 2858 - 2865