Development of a sensitive LC-APCI-MS/MS method for simultaneous determination of eleven nitrosamines in valsartan and irbesartan with a simple extraction approach

被引:5
|
作者
Mavis, Murat Emrah [1 ]
Gursu, Gokce Goksu [1 ]
Cagatay, Nese Ular [1 ]
机构
[1] Sem Laboratuar Cihazlari Pazarlama San Ve Tic Inc, R&D Ctr, TR-34746 Istanbul, Turkiye
关键词
N-nitrosamines; Sartans; Liquid chromatography; Mass spectrometry; Simultaneous determination;
D O I
10.1016/j.jchromb.2023.123593
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Nitrosamines (NAs) are potent genotoxic agents (GAs) in several animal species, and some are classified as probable or possible human carcinogens by the International Agency for Research on Cancer (IARC). In July 2018, angiotensin II receptor blockers (ARBs) which are used to treat high blood pressure have been recalled owing to contamination with NAs. In this study, a simple and sensitive method for the determination of eleven NAs in a single analysis was developed, using atmospheric pressure chemical ionisation source coupled liquid chromatography tandem mass spectrometer (LC-APCI-MS/MS). By performing the 17 min-run in dynamic multiple reaction monitoring (dMRM) mode, eleven NAs were separated on a Poroshell HPH C18 (4.6 x 150 mm, 2.7 mu m) column with gradient elution implementing mobile phase A consisting of 0.2 % formic acid in water and mobile phase B consisting of methanol. The developed analytical method was successfully applied in both active pharmaceutical ingredients (APIs) and finished products (FPs) of valsartan and irbesartan with straightforward and effective extraction procedures. Good linearity with a correlation coefficient (R2) > 0.996 was achieved over the concentration in a range of 0.5-50 ng/mL. The limits of detection (LODs) ranged in 0.001-0.008 ppm and limits of quantitation (LOQs) ranged in 0.008-0.05 ppm of the method fulfilled thresholds of US Food and Drug Administration (US-FDA) and European Medicines Agency (EMA) for testing of GAs in valsartan and irbesartan. The accuracy of the proposed method ranged from 73.1 % to 115.2 % for APIs and the relative standard deviation (RSD %) was <= 11.3 while these validation parameters were in the range of 80.2-128.5 % and <= 10.6 for FPs, respectively.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Development and validation of an LC-APCI-MS/MS method for the determination of phenethyl isothiocyanate in human plasma
    Zheng, Li
    Zheng, Feng
    BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (04) : 619 - 625
  • [2] Determination of cypermethrin in salmon by LC-APCI-MS
    Sorensen, LK
    Hansen, H
    ANALYTICAL LETTERS, 2003, 36 (01) : 191 - 201
  • [3] Sensitive Analysis of Wilforidine in Human Plasma by LC-APCI-MS/MS
    Meiqiang Cai
    Chenyi Shen
    Micong Jin
    Chromatographia, 2013, 76 : 985 - 991
  • [4] Sensitive Analysis of Wilforidine in Human Plasma by LC-APCI-MS/MS
    Cai, Meiqiang
    Shen, Chenyi
    Jin, Micong
    CHROMATOGRAPHIA, 2013, 76 (15-16) : 985 - 991
  • [5] Development of a sensitive LC-MS/MS method for simultaneous determination of three nitrosamines in losartan API and assessment of nitrosamines formation
    Carlos, Graciela
    Martini, Paulo R. R.
    Machioli, Lilian F.
    Garcia, Cassia, V
    Paim, Clesio S.
    de Oliveira, Tiago Franco
    Mendez, Andreas S. L.
    MICROCHEMICAL JOURNAL, 2025, 208
  • [6] Simultaneous separation and determination of arginine and methylated arginines in human plasma with LC-APCI-MS method
    Huang, LF
    Liang, YZ
    Guo, FQ
    Chen, BM
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2004, 25 (02): : 233 - 237
  • [7] Simultaneous quantification of opiates, cocaine, and metabolites in hair by LC-APCI-MS/MS
    Scheidweiler, KB
    Huestis, MA
    ANALYTICAL CHEMISTRY, 2004, 76 (15) : 4358 - 4363
  • [8] Fast and Reliable Determination of Voriconazole in Human Plasma by LC-APCI-MS/MS
    Xiong, Xin
    Duan, Jingli
    Zhai, Suodi
    Wang, Lijue
    Lan, Xi
    BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2010, 74 (10) : 2151 - 2153
  • [9] Development and validation of an LC-APCI-MS method for the determination of bisphenol A in hair samples of Greek population
    Tzatzarakis, Manolis
    Vakonaki, Elena
    Kavvalakis, Matthaios
    Stivaktakis, Polychronis
    Heretis, Ioannis
    Barbounis, Emmanouil
    Vardavas, Alexandros
    Barmpas, Michael
    Tsatsakis, Aristidis
    TOXICOLOGY LETTERS, 2014, 229 : S227 - S227
  • [10] LC-APCI-MS Simultaneous Determination of Barbital, Amobarbital, Phenobarbital and Secobarbital in Human Plasma
    Ye, Faqing
    Pan, Jianchun
    Hu, Guoxin
    Lin, Dan
    Zhu, Jiayin
    Wang, Xianqin
    CHROMATOGRAPHIA, 2010, 72 (7-8) : 743 - 746