摘要
Future experiments at high-luminosity hadron colliders will involve unprecedent levels of pile up, calling for ultrafast detectors in order to add time information to distinguish between particle tracks. The unique geometry of 3D sensors enables to achieve very good timing performance, with the additional benefit of high radiation hardness. Remarkable results in terms of temporal resolution have been reported for 3D sensors with columnar electrodes (-30 ps) and even better with trenched electrodes (-10 ps), because of a more uniform distribution of the electric field and weighting field. However, 3D-trench technology is more complex, and has still to be optimized in terms of both fabrication process and pixel layout. To this purpose, as an alternative to the existing design which features continuous (p+) ohmic trenches, we propose a new variant by introducing a gap (-10 mu m) in the p+ trenches and placed offset with respect to the readout (n+) trenches, so as to reduce the risk of lithographical defects that were observed in mm's long ohmic trenches, thus improving the fabrication yield.TCAD simulations confirmed that the impact of the gap on the uniformity of the electric and weighting field is minimum, and good charge collection efficiency performance is preserved up to large fluences. Further Monte Carlo time-resolved simulations are performed on both the standard and modified geometries showing comparable temporal resolutions.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Timing characterisation of 3D-trench silicon sensors
    Lai, A.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (09):
  • [2] Modeling and simulation of charge collection properties for 3D-trench electrode detector
    Ding, Hao
    Chen, Jianwei
    Li, Zheng
    Yan, Shaoan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 796 : 29 - 33
  • [3] 3D simulations of device performance for 3D-Trench electrode detector
    Chen, Jianwei
    Ding, Hao
    Li, Zheng
    Yan, Shaoan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 796 : 34 - 37
  • [4] A systematic study of BNL's 3D-Trench Electrode detectors
    Montalbano, A.
    Bassignana, D.
    Li, Z.
    Liu, S.
    Lynn, D.
    Pellegrini, G.
    Tsybychev, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 765 : 23 - 28
  • [5] A Modified 3D-Trench Pixel Detector: Proof of Concept by TCAD Simulations
    Boughedda, Abderrezak
    Latreche, Saida
    Lakhdara, Maya
    Dalla Betta, Gian-Franco
    FRONTIERS IN PHYSICS, 2022, 10
  • [6] Development of Ultra-fast 3D Silicon Detectors: 3D Simulation and Modeling of 3D-trench Electrode Detector
    Liu, Man-Wen
    Li, Zheng
    PROCEEDINGS OF THE 3RD ANNUAL INTERNATIONAL CONFERENCE ON ADVANCED MATERIAL ENGINEERING (AME 2017), 2017, 110 : 99 - 105
  • [7] Electrical Properties of Ultra-Fast 3D-Trench Electrode Silicon Detector
    Liu, Manwen
    Zhou, Tao
    Li, Zheng
    MICROMACHINES, 2020, 11 (07)
  • [8] 3D simulations of device performance for open-shell 3D-Trench electrode detector
    Liu, Xiaojie
    Tang, Lipeng
    Liao, Chuan
    Li, Zheng
    PROCEEDINGS OF THE 2ND INTERNATIONAL FORUM ON MANAGEMENT, EDUCATION AND INFORMATION TECHNOLOGY APPLICATION (IFMEITA 2017), 2017, 130 : 574 - 577
  • [9] New BNL 3D-Trench electrode Si detectors for radiation hard detectors for sLHC and for X-ray applications
    Li, Zheng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 658 (01): : 90 - 97
  • [10] Radiation Hardness Property of Ultra-Fast 3D-Trench Electrode Silicon Detector on N-Type Substrate
    Liu, Manwen
    Li, Xinqing
    Cheng, Wenzheng
    Li, Zheng
    Li, Zhihua
    MICROMACHINES, 2021, 12 (11)