Visual Blood, a 3D Animated Computer Model to Optimize the Interpretation of Blood Gas Analysis

被引:1
|
作者
Schweiger, Giovanna [1 ]
Malorgio, Amos [1 ]
Henckert, David [1 ]
Braun, Julia [2 ,3 ]
Meybohm, Patrick [4 ]
Hottenrott, Sebastian [4 ]
Froehlich, Corinna [4 ]
Zacharowski, Kai [5 ]
Raimann, Florian J. [5 ]
Piekarski, Florian [5 ]
Noethiger, Christoph B. [1 ]
Spahn, Donat R. [1 ]
Tscholl, David W. [1 ]
Roche, Tadzio R. [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Dept Anaesthesiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich, Epidemiol Biostat & Prevent Inst, Dept Epidemiol, CH-8006 Zurich, Switzerland
[3] Univ Zurich, Epidemiol Biostat & Prevent Inst, Dept Biostat, CH-8006 Zurich, Switzerland
[4] Univ Wurzburg, Univ Hosp Wuerzburg, Dept Anaesthesiol Intens Care Emergency & Pain Med, D-97080 Wurzburg, Germany
[5] Goethe Univ Frankfurt, Univ Hosp Frankfurt, Dept Anaesthesiol Intens Care Med & Pain Therapy, D-60590 Frankfurt, Germany
来源
BIOENGINEERING-BASEL | 2023年 / 10卷 / 03期
关键词
blood gas analysis; medical devices; point-of-care-testing; situational awareness; technology;
D O I
10.3390/bioengineering10030293
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Acid-base homeostasis is crucial for all physiological processes in the body and is evaluated using arterial blood gas (ABG) analysis. Screens or printouts of ABG results require the interpretation of many textual elements and numbers, which may delay intuitive comprehension. To optimise the presentation of the results for the specific strengths of human perception, we developed Visual Blood, an animated virtual model of ABG results. In this study, we compared its performance with a conventional result printout. Seventy physicians from three European university hospitals participated in a computer-based simulation study. Initially, after an educational video, we tested the participants' ability to assign individual Visual Blood visualisations to their corresponding ABG parameters. As the primary outcome, we tested caregivers' ability to correctly diagnose simulated clinical ABG scenarios with Visual Blood or conventional ABG printouts. For user feedback, participants rated their agreement with statements at the end of the study. Physicians correctly assigned 90% of the individual Visual Blood visualisations. Regarding the primary outcome, the participants made the correct diagnosis 86% of the time when using Visual Blood, compared to 68% when using the conventional ABG printout. A mixed logistic regression model showed an odds ratio for correct diagnosis of 3.4 (95%CI 2.00-5.79, p < 0.001) and an odds ratio for perceived diagnostic confidence of 1.88 (95%CI 1.67-2.11, p < 0.001) in favour of Visual Blood. A linear mixed model showed a coefficient for perceived workload of -3.2 (95%CI -3.77 to -2.64) in favour of Visual Blood. Fifty-one of seventy (73%) participants agreed or strongly agreed that Visual Blood was easy to use, and fifty-five of seventy (79%) agreed that it was fun to use. In conclusion, Visual Blood improved physicians' ability to diagnose ABG results. It also increased perceived diagnostic confidence and reduced perceived workload. This study adds to the growing body of research showing that decision-support tools developed around human cognitive abilities can streamline caregivers' decision-making and may improve patient care.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] A computer 3D animated graphical interface for control and teleoperation of robot system
    Dong, FF
    Meng, M
    SMC '97 CONFERENCE PROCEEDINGS - 1997 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS, VOLS 1-5: CONFERENCE THEME: COMPUTATIONAL CYBERNETICS AND SIMULATION, 1997, : 778 - 783
  • [22] Reflectance analysis for 3D computer graphics model generation
    Sato, Y
    Ikeuchi, K
    GRAPHICAL MODELS AND IMAGE PROCESSING, 1996, 58 (05): : 437 - 451
  • [23] 3D Reconstruction of blood vessels
    Ali Al Moussawi
    Cedric Galusinski
    Christian Nguyen
    Engineering with Computers, 2015, 31 : 775 - 790
  • [24] 3D Printed Blood Vessels
    Cook, A. D.
    Dodge, C.
    Day, D.
    Griggs, J.
    TISSUE ENGINEERING PART A, 2014, 20 : S122 - S122
  • [25] 3D Reconstruction of blood vessels
    Al Moussawi, Ali
    Galusinski, Cedric
    Nguyen, Christian
    ENGINEERING WITH COMPUTERS, 2015, 31 (04) : 775 - 790
  • [26] COMPUTER-ASSISTED BLOOD-GAS ANALYSIS
    VOIGT, E
    INTENSIVE CARE MEDICINE, 1980, 6 (01) : 82 - 82
  • [27] Transcriptomic analysis of a 3D blood–brain barrier model exposed to disturbed fluid flow
    Nesrine Bouhrira
    Brandon J. DeOre
    Kiet A. Tran
    Peter A. Galie
    Fluids and Barriers of the CNS, 19
  • [28] Facial Expressions Recognition by Animated Motion of Candide 3D Model
    Chang, Xin
    Skarbek, Wladyslaw
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS 2018, 2018, 10808
  • [29] Supporting ultrasound diagnosis using an animated 3D model of the heart
    Berlage, T
    Fox, T
    Grunst, G
    Quast, KJ
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MULTIMEDIA COMPUTING AND SYSTEMS, 1996, : 34 - 39
  • [30] Analysis on the computer 3D stereogram
    Beijing Inst of Technology, Beijing, China
    Guangxue Jishu, 1 (26-28, 31):