Full-Scale Floor System Testing for Future Hot-Rolled Asymmetric Steel I-Beams

被引:1
|
作者
Davis, Sheyenne [1 ]
Stoddard, Eric [1 ]
Yarnold, Matthew T. [1 ]
机构
[1] Texas A&M Univ, Zachry Dept Civil Engn, 3136 TAMU, College Stn, TX 77845 USA
关键词
Structural steel; Hot roll; Stability; Composite; Floor system; COMPOSITE BEAM;
D O I
10.1061/JSENDH.STENG-11610
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The presented study conveys the initial full-scale experimental study for future hot-rolled asymmetric steel I-beams, termed A-shapes. The primary use for these beams is residential building floor systems. Current systems commonly utilize concrete solutions, which achieve a shallow depth for optimal floor-to-floor heights. However, these floor systems are relatively slow to construct because of the amount of formwork, rebar and post-tensioning placement, and shoring needed. The shallow-depth steel-concrete floor system concept explored in this research aims to improve the speed and efficiency of residential building construction. This increase in speed is achieved through hot-rolled steel A-shapes, which reduce the fabrication time for beam production. These steel shapes have a wide bottom flange that can support precast concrete panels or deep metal decking. Therefore, a relatively easy to assemble shallow-depth system can be achieved. The research study presented herein includes the experimental feasibility testing of a full-scale shallow-depth steel-concrete floor system to further the knowledge of A-shape performance in such systems. The floor system concept evaluated consisted of three steel A-shapes, precast hollow-core concrete panels, and a cast-in-place concrete topping slab. The testing involved taking measurements during construction, service live loading, and loading of the system to failure. The major unknowns were constructability, stability during construction, live load performance, and composite behavior. This experiment revealed that the system was constructed easily and rapidly and also remained stable during construction. The system performed well under service live load, experiencing deflections equivalent to L/3,000. The system failed due to the bond breaking between the concrete and steel, going noncomposite after experiencing partially composite behavior. This occurred at an actuator load equivalent to five times the design service live load. All of this indicates that the floor system concept using A-shapes is a legitimate path forward to faster construction of residential facilities. This validates the need for the research toward standardized A-shapes in the United States.
引用
收藏
页数:15
相关论文
共 29 条
  • [21] Full-scale Model Test on Flexural Performance of Double-broken Line Pre-tensioned High-strength Concrete I-beams
    Wang L.-B.
    Chen J.
    Yang Y.-Q.
    Zhu Z.
    Sun B.-L.
    Shu H.
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2022, 36 (07): : 169 - 179
  • [22] Full-scale push-out testing of headed stud-steel block connectors in prefabricated steel-concrete composite beams
    Liu, Jiepeng
    Xie, Jincheng
    Xiong, Gang
    Wang, Xuanding
    Zou, Yunhe
    Shu, Rui
    Chen, Frank
    ENGINEERING STRUCTURES, 2023, 285
  • [23] Prediction of the deflection and residual stress in controlled cooling of hot-rolled steel beams including load and arbitrary support - Part I. Computational model
    Boyadjiev, II
    Thomson, PF
    Lam, YC
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2004, 147 (03) : 370 - 376
  • [24] Experimental and analytical study of lightweight floor system built-up with cold-formed profile steel sheet and hot-rolled steel plate (CFPSS-HRSP)
    Govindan, Senthil Kumar
    Madhavan, Mahendrakumar
    STRUCTURES, 2019, 22 : 291 - 309
  • [25] Design, Analysis, and Full-Scale Testing of the Rolled Groove Gasket Joint System in AWWA C303 Bar-Wrapped, Steel-Cylinder Concrete Pressure Pipe
    Najafi, Mohammad
    Ramirez, Guillermo
    Mielke, Richard
    Keil, Brent
    Davidenko, Glenn
    Rahman, Shah
    Jain, Abhay
    JOURNAL OF PIPELINE SYSTEMS ENGINEERING AND PRACTICE, 2013, 4 (03) : 156 - 169
  • [26] Full-Scale Test of a Steel-Concrete Composite Floor System with Moment-Resisting Connections under a Middle-Edge Column Removal Scenario
    Wang, Junjie
    Wang, Wei
    Bao, Yihai
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (05)
  • [27] Experimental Seismic Response of a Full-Scale Cold-Formed Steel-Framed Building. I: System-Level Response
    Peterman, Kara D.
    Stehman, Matthew J. J.
    Madsen, Rob L.
    Buonopane, Stephen G.
    Nakata, Narutoshi
    Schafer, Benjamin W.
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (12)
  • [28] IMAGE-BASED MONITORING SYSTEM FOR CONCEALED SUSPENDED PIPING IN BUILDINGS Verification in shaking table testing of a full-scale steel frame with hospital functionality
    Sakakibara, Yurie
    Kawamata, Yohsuke
    Fujita, Kohei
    Kurata, Masahiro
    Journal of Structural and Construction Engineering, 2022, 87 (798): : 725 - 736
  • [29] Seismic performance of a 3D full-scale high-ductility steel-concrete composite moment-resisting structure-Part I: Design and testing, procedure
    Braconi, A.
    Bursi, O. S.
    Fabbrocino, G.
    Salvatore, W.
    Tremblay, R.