Development of an open project rectangular collimator for use with intraoral dental X-ray unit

被引:0
|
作者
Poletto, Marina C. [1 ]
Thomazi, Eduardo [2 ]
Zorzi, Janete E. [1 ]
Gamba, Thiago O. [1 ,3 ]
Perottoni, Claudio A. [1 ]
机构
[1] Univ Caxias Do Sul UCS, Grad Program Hlth Sci PPGCS, Francisco Getulio Vargas 1130, BR-95070560 Caxias Do Sul, RS, Brazil
[2] Fed Inst Educ Sci & Technol Rio Grande Do Sul IFRS, Campus Caxias Do Sul 1730,Avelino Antonio Souza, BR-95043700 Caxias Do Sul, Rio Grande Do S, Brazil
[3] Fed Univ Rio Grande Do Sul UFRGS, Dent Sch, Surg & Orthoped Dept, Ramiro Barcelos 2492, BR-90035003 Porto Alegre, RS, Brazil
关键词
Radiation protection; Radiology; Radiation dose; 3D printing; RADIOGRAPHS; REDUCTION; RADIATION;
D O I
10.1007/s12194-023-00772-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this work, an open beam-limiting device, consisting of a rectangular collimator to be coupled to an intraoral dental X-ray device, was made using recycled lead sheets as a radiation-absorbing element. The collimator was designed for 3D printing, and using Spektr 3.0 software, the number of lead sheets needed to absorb excess radiation was calculated. The rectangular collimator reduced the radiation dose to patients by 65% when using four layers of recycled lead sheets (saturating with a 70% reduction in radiation dose at the limit of eight or more sheets of lead). The rectangular collimator does not negatively impact the quality of the radiological image, is available as an open design for 3D printing, and can be built with materials that are easily accessible to the dentist, facilitating its use in clinical practice and reducing the patient's exposure to ionizing radiation.
引用
收藏
页码:315 / 321
页数:7
相关论文
共 50 条
  • [21] Use of dental film for x-ray of finger
    Lovelady, R
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1928, 91 : 819 - 819
  • [22] OPTICAL ALIGNMENT OF AN X-RAY COLLIMATOR
    HOEKSTRA, R
    DARNAUD, TE
    VANBEEK, HF
    APPLIED OPTICS, 1981, 20 (20): : 3630 - 3634
  • [23] MODULATION COLLIMATOR IN X-RAY ASTRONOMY
    BRADT, H
    GARMIRE, G
    ODA, M
    SPADA, G
    SREEKANT.BV
    GORENSTE.P
    GURSKY, H
    SPACE SCIENCE REVIEWS, 1968, 8 (04) : 471 - &
  • [24] A MICROCHANNEL PLATE X-RAY COLLIMATOR
    YAMAGUCHI, N
    AOKI, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1987, 26 (12): : 2111 - 2115
  • [25] A parabolic mirror x-ray collimator
    Franks, A
    Jackson, K
    Yacoot, A
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2000, 11 (05) : 484 - 488
  • [26] EVALUATION OF AN ECCENTRIC X-RAY COLLIMATOR
    LARSEN, RD
    KASE, KR
    BJARNGARD, BE
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1980, 6 (10): : 1451 - 1452
  • [27] SLITLESS X-RAY COLLIMATOR.
    Mingazin, T.A.
    Zelenov, V.I.
    Leikin, V.N.
    Instruments and experimental techniques New York, 1981, 24 (1 pt 2): : 244 - 246
  • [28] Intraoral panoramic X-ray study
    Patrakhov, N.N.
    Meditsinskaya Tekhnika, 2001, (05): : 38 - 40
  • [30] Attitudes of Swedish dentists to the choice of dental X-ray film and collimator for oral radiology
    Svenson, B
    Soderfeldt, B
    Grondahl, HG
    DENTOMAXILLOFACIAL RADIOLOGY, 1996, 25 (03) : 157 - 161