Experimental study of precast self-centering concrete shear walls with external friction dampers

被引:13
|
作者
Liu, Yang [1 ]
Zhou, Wei [1 ,2 ,3 ]
Xie, Xinying [1 ]
机构
[1] Harbin Inst Technol, Sch Civil Engn, 73 Huanghe Rd, Harbin 150090, Heilongjiang, Peoples R China
[2] Harbin Inst Technol & Control, Minist Educ, Key Lab Struct Dynam Behav, 73 Huanghe Rd, Harbin 150090, Heilongjiang, Peoples R China
[3] Harbin Inst Technol, Minist Ind & Informat Technol, Key Lab Smart Prevent & Mitigat Civil Engn Disaste, 73 Huanghe Rd, Harbin 150090, Heilongjiang, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Self-centering shear wall; Friction dampers; Post-earthquake recovery; Dissipating capacity; Self-centering ability; LATERAL LOAD BEHAVIOR; SEISMIC PERFORMANCE; DESIGN; PREWEC;
D O I
10.1016/j.jobe.2023.106182
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Self-centering walls perform relatively well in reducing structural damage and residual defor-mation owing to the joint rocking mechanism. Nevertheless, drawbacks of the self-centering walls were limited robustness and redundancy, thus sufficient dissipating capacity is essential for improving stiffness, reducing seismic response, and controlling structural collapse. Among all these dampers used in self-centering systems in previous studies, slip-friction dampers are highly preferred because of their simplicity, perfect rigid-plastic hysteresis characteristic, large stroke, and stable dissipating capacity. After the earthquake ceases, friction force can be eliminated by loosening the tightening bolts to help facilitate post-earthquake recovery, and it is convenient to be replaced or repaired. In the present study, experiments of asymmetric friction dampers with brass-steel interfaces were conducted. To obtain the optimal characteristics for stable dissipating, different configurations of slip-friction dampers were designed and tested. The friction dampers were further installed vertically at the base rocking joint of the self -centering shear walls, and the performance of the walls was studied under horizontal quasi-static cyclic loading. Application of the friction dampers significantly increases the energy dissipating capacity and the post-yield stiffness. The energy dissipating ratio improved up to 81.2% compared to rocking walls with no additional damping. Damage was limited to the brass shims in friction dampers, while wall specimens were able to exhibit up to 3.0% horizontal drift without cracks, degradation, and significant concrete damage at the boundary elements. An average maximum residual drift of both positive and negative directions observed at the end of the test was 0.415% at 3.0% horizontal drift, that major structural realignment is not required, and repair of the structure is practically feasible.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Seismic performance of partial self-centering prestressed concrete frames with friction dampers
    Huang, Linjie
    Wen, Hongwei
    Jiang, Kaixi
    Wei, Yang
    Zhou, Zhen
    Xie, Qin
    Qian, Zhendong
    STRUCTURES, 2024, 62
  • [32] Design and experimental verification of disc spring devices in self-centering reinforced concrete shear walls
    Xiao, Shui-Jing
    Xu, Long-He
    Li, Zhong-Xian
    STRUCTURAL CONTROL & HEALTH MONITORING, 2020, 27 (07):
  • [33] Experimental investigation of self-centering hybrid concrete shear walls subjected to horizontal cyclic loading
    Liu, Yang
    Zhou, Wei
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2021, 50 (14): : 3754 - 3770
  • [34] Self-Centering Column Base Connections with Friction Dampers
    Liu, Judy
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION, 2020, 57 (02): : 135 - 143
  • [35] Self-centering column base connections with friction dampers
    Liu, Judy
    Engineering Journal, 2020, 57 (02): : 135 - 143
  • [36] Self-centering friction spring dampers for seismic resilience
    Wang, Wei
    Fang, Cheng
    Zhao, Yashuo
    Sause, Richard
    Hu, Shuling
    Ricles, James
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2019, 48 (09): : 1045 - 1065
  • [37] Lateral Performance of Self-Centering Steel-Timber Hybrid Shear Walls with Slip-Friction Dampers: Experimental Investigation and Numerical Simulation
    Li Z.
    Chen F.
    He M.
    Zhou R.
    Cui Y.
    Sun Y.
    He G.
    Journal of Structural Engineering (United States), 2021, 147 (01):
  • [38] Experimental evaluation of self-centering hybrid coupled wall subassemblies with friction dampers
    Zareian, Mohammad Sajjad
    Esfahani, Mohammad Reza
    Hosseini, Abdollah
    ENGINEERING STRUCTURES, 2020, 214 (214)
  • [39] Effect of infill walls on progressive collapse behavior of self-centering precast concrete frame
    Wang, Haoran
    Li, Shuang
    Zhai, Changhai
    STRUCTURES, 2024, 59
  • [40] Parametric Investigation of Self-Centering Prestressed Concrete Frame Structures with Variable Friction Dampers
    Huang, Linjie
    Qian, Zhendong
    Meng, Yuan
    Jiang, Kaixi
    Zhang, Jingru
    Sang, Chenxu
    BUILDINGS, 2023, 13 (12)