Numerical Model of the Double-Pipe System with Protective Layer

被引:3
|
作者
Granda, Mariusz [1 ,2 ]
Trojan, Marcin [1 ]
机构
[1] Cracow Univ Technol, Dept Thermal Proc Air Protect & Waste Utilizat, Krakow, Poland
[2] Cracow Univ Technol, Dept Thermal Proc Air Protect & Waste Utilizat, Al Jana Pawla II 37, PL-31864 Krakow, Poland
关键词
THERMAL BARRIER COATINGS; CONDUCTIVITY; SUPERHEATER; FLOW; TEMPERATURE; TRANSITION; TUBE;
D O I
10.1080/01457632.2022.2162011
中图分类号
O414.1 [热力学];
学科分类号
摘要
Nowadays, higher performance is being sought in newly built power plants. The efficiency of power plants is mainly achieved by maximizing the steam parameters. Consequently, ever more expensive high-alloy steels are being used. For this reason, design concepts, in which high efficiency with lower investment costs are becoming increasingly popular. Such an innovation is the double-pipe system with a protective coating, which provides thermal insulation for the primary pipe in which the supercritical steam flows. This pipe is also cooled by an external flow by the steam with lower parameters. The article presents the developed two-dimensional numerical model. The use of the Galerkin method enables the complete transient analysis of a double-pipe system to be carried out, considering temperature-dependent material properties. The numerical model was compared with the computational fluid dynamics model. The temperature gradient in the inner pipe wall with and without coating was determined. In addition, the response of the wall temperature to a change in steam temperature was investigated. As observed, the protective layer can improve boiler performance characteristics when applied to thick-walled boiler components. It can also enable the use of less demanding steel.
引用
收藏
页码:1833 / 1846
页数:14
相关论文
共 50 条
  • [31] Experimental and Numerical Study of Double-Pipe Evaporators Designed for CO2 Transcritical Systems
    Yang, Junlan
    Ning, Shuying
    PROCESSES, 2019, 7 (08)
  • [32] Numerical analysis reliability control for a double-pipe heat exchanger with virtual entropy generation method
    Tavangar, Tooran
    Amoli, Behzad Siavash
    Delavar, Mojtaba Aghajani
    HEAT TRANSFER-ASIAN RESEARCH, 2019, 48 (05): : 1933 - 1945
  • [33] Numerical simulation of nanofluid turbulent flow in a double-pipe heat exchanger equipped with circular fins
    Seyed Shahab Mozafarie
    Kourosh Javaherdeh
    Omid Ghanbari
    Journal of Thermal Analysis and Calorimetry, 2021, 143 : 4299 - 4311
  • [34] Numerical investigation of thermohydraulic performance of air to water double-pipe heat exchanger with helical fins
    El Maakoul, Anas
    El Metoui, Mustapha
    Ben Abdellah, Abdellatif
    Saadeddine, Said
    Meziane, Mohamed
    APPLIED THERMAL ENGINEERING, 2017, 127 : 127 - 139
  • [35] Laminar convection in the annulus of a double-pipe with triangular fins
    Syed, Khalid S.
    Ishaq, Muhammad
    Bakhsh, Muhammad
    COMPUTERS & FLUIDS, 2011, 44 (01) : 43 - 55
  • [36] Tube temperature variations in a double-pipe heat exchanger
    Smith, JFD
    TRANSACTIONS OF THE AMERICAN INSTITUTE OF CHEMICAL ENGINEERS, 1935, 31 : 588 - 591
  • [37] Bounded positive control for double-pipe heat exchangers
    Zavala-Rio, A.
    Astorga-Zaragoza, C. M.
    Hernandez-Gonzalez, O.
    CONTROL ENGINEERING PRACTICE, 2009, 17 (01) : 136 - 145
  • [38] Experimental studies of a double-pipe helical heat exchanger
    Rennie, TJ
    Raghavan, VGS
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2005, 29 (08) : 919 - 924
  • [39] CORRECTION FACTORS FOR DOUBLE-PIPE HEAT-EXCHANGERS
    DURAND, AA
    MALDONADO, JM
    CHEMICAL ENGINEERING, 1991, 98 (04) : 163 - 164
  • [40] NATURAL VIBRATION CHARACTERISTICS OF COAXIAL DOUBLE-PIPE STRUCTURE
    FUTAKAWA, M
    KIKUCHI, K
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1985, 27 (06): : 553 - 562