Implementation of triggered kilovoltage imaging for stereotactic radiotherapy of the spine for patients with spinal fixation hardware

被引:3
|
作者
Cetnar, Ashley J. [1 ,2 ,3 ]
Degnan, Michael [1 ,2 ]
Pichler, Joseph [1 ,2 ]
Jain, Sagarika [1 ,2 ]
Morelli, Samantha [1 ,2 ]
Thomas, Evan [1 ,2 ]
Elder, J. Bradley [1 ,2 ]
Scharschmidt, Thomas J. [1 ,2 ]
Palmer, Joshua D. [1 ,2 ]
Blakaj, Dukagjin M. [1 ,2 ]
机构
[1] Ohio State Univ, James Canc Hosp, 460 W 10th Ave, Columbus, OH 43210 USA
[2] Ohio State Univ, Solove Res Inst, Dept Radiat Oncol, 460 W 10th Ave, Columbus, OH 43210 USA
[3] Dept Radiat Oncol, A201 Off F,460 W 10th Ave, Columbus, OH 43210 USA
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2023年 / 25卷
关键词
Intrafraction motion review; Triggered imaging; Advanced imaging; Spine; Stereotactic; BODY RADIATION-THERAPY; INTRAFRACTION MOTION; CONSENSUS GUIDELINES; RESPIRATORY MOTION; METASTASES; PROSTATE; RADIOSURGERY; MANAGEMENT; CANCER; CORD;
D O I
10.1016/j.phro.2023.100422
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Mitigation of intrafraction motion (IM) is valuable in stereotactic radiotherapy (SRT) radiotherapy where submillimeter accuracy is desired. The purpose of this study was to investigate the application of triggered kilovoltage (kV) imaging for spine SRT patients with hardware by correlating kV imaging with patient motion and summarizing implications of tolerance for IM based on calculated dose.Materials and methods: Ten plans (33 fractions) were studied, correlating kV imaging during treatment with preand post-treatment cone beam computed tomography (CBCT). Images were taken at 20-degree gantry angle intervals during the arc-based treatment. The contour of the hardware with a 1 mm expansion was displayed at the treatment console to manually pause treatment delivery if the hardware was visually detected outside the contour. The treatment CBCTs were compared using retrospective image registration to assess the validity of contour-based method for pausing treatment. Finally, plans were generated to estimate dose volume objective differences in case of 1 mm deviation.Results: When kV imaging during treatment was used with the 1 mm contour, 100 % of the post-treatment CBCTs reported consistent results. One patient in the cohort exhibited motion greater than 1 mm during treatment which allowed intervention and re-setup during treatment. The average translational motion was 0.35 mm. Treatment plan comparison at 1 mm deviation showed little differences in calculated dose for the target and cord.Conclusions: Utilizing kV imaging during treatment is an effective method of assessing IM for SRT spine patients with hardware without increasing treatment time.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Kilovoltage projection streaming-based tracking application (KiPSTA): First clinical implementation during spine stereotactic radiation surgery
    Kim, Jihun
    Park, Yang-Kyun
    Edmunds, David
    Oh, Kevin
    Sharp, Gregory C.
    Winey, Brian
    ADVANCES IN RADIATION ONCOLOGY, 2018, 3 (04) : 682 - 692
  • [22] Outcomes Specific to Spinal Metastases with Paraspinal Disease Extension Following Spine Stereotactic Body Radiotherapy
    Ong, W. L.
    Zeng, L.
    Soliman, H.
    Myrehaug, S. D.
    Detsky, J.
    Chen, H.
    Ruschin, M. E.
    Atenafu, E.
    Larouche, J.
    Maralani, P.
    Sahgal, A.
    Tseng, C. L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E142 - E143
  • [23] Novel Intrafraction Motion Tracking During Postoperative Spine Stereotactic Irradiation for a Patient With Carbon Fiber Fixation Hardware
    Lee-Poprocki, Hyeri
    Ritter, Alex R.
    Upadhyay, Rituraj
    Perlow, Haley K.
    Ayan, Ahmet S.
    Cetnar, Ashley J.
    Degnan, Michael
    Scharschmidt, Thomas J.
    Mendel, Ehud
    Blakaj, Dukagjin M.
    Thomas, Evan M.
    Chakravarthy, Vikram B.
    Elder, James B.
    Palmer, Joshua D.
    PRACTICAL RADIATION ONCOLOGY, 2023, 13 (06) : 510 - 516
  • [24] Feasibility of Intrafraction Motion Management Using Triggered KV Imaging During Spine Stereotactic Radiosurgery
    Koo, J.
    Nardella, L.
    Degnan, M.
    Andreozzi, J.
    Yu, H.
    Penagaricano, J.
    Johnstone, P.
    Oliver, D.
    Ahmed, K.
    Rosenburg, S.
    Wuthrick, E.
    Diaz, R.
    Feygelman, V.
    Moros, E.
    Redler, G.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [25] Recursive Partitioning Analysis of Patients with Spine Metastases Treated with Stereotactic Body Radiotherapy
    Rodriguez-Lopez, J. L.
    Flickinger, J. C., Sr.
    Gerszten, P. C.
    Amankulor, N.
    Burton, S. A.
    Olson, A. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E125 - E125
  • [26] Correlation between small-volume spinal cord doses for spine stereotactic body radiotherapy (SBRT)
    Ma, Lijun
    Wang, Lei
    Lee, Young
    Tseng, Chia-Lin
    Soltys, Scott
    Braunstein, Steve
    Sahgal, Arjun
    JOURNAL OF RADIOSURGERY AND SBRT, 2018, 5 (03): : 229 - 236
  • [27] Separation Surgery, Fixation With Carbon-Fiber Implants, and Stereotactic Body Radiotherapy for Oligometastatic Spinal Disease
    Galloway, Richard
    Gikas, Nicholas
    Golomohammad, Ramez
    Sherriff, Jenny
    Czyz Sr, Marcin
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (11)
  • [28] Stereotactic Body Radiotherapy for Renal Cell Spinal Metastases is Optimal in Patients with Few Spinal Metastases
    Balagamwala, E. H.
    Koyfman, S. A.
    Reddy, C. A.
    Djemil, T.
    Hunter, G. K.
    Angelov, L.
    Suh, J. H.
    Xia, P.
    Chao, S. T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S678 - S679
  • [29] MRI for Spinal Cord Visualization near Surgical Hardware to Replace CT Myelogram for Spine Sarcoma Radiotherapy
    Huh, S. N.
    Park, J. Y.
    Johnson, P.
    Brooks, E. D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : S52 - S52
  • [30] Using Kilovoltage Triggered Imaging to Improve Intrafraction Motion Management for Free Breathing and Breath Hold Lung Stereotactic Body Radiation Therapy
    Moazzezi, M.
    Xia, P.
    Stephans, K.
    Guo, B.
    MEDICAL PHYSICS, 2022, 49 (06) : E973 - E974