Implementation of triggered kilovoltage imaging for stereotactic radiotherapy of the spine for patients with spinal fixation hardware

被引:3
|
作者
Cetnar, Ashley J. [1 ,2 ,3 ]
Degnan, Michael [1 ,2 ]
Pichler, Joseph [1 ,2 ]
Jain, Sagarika [1 ,2 ]
Morelli, Samantha [1 ,2 ]
Thomas, Evan [1 ,2 ]
Elder, J. Bradley [1 ,2 ]
Scharschmidt, Thomas J. [1 ,2 ]
Palmer, Joshua D. [1 ,2 ]
Blakaj, Dukagjin M. [1 ,2 ]
机构
[1] Ohio State Univ, James Canc Hosp, 460 W 10th Ave, Columbus, OH 43210 USA
[2] Ohio State Univ, Solove Res Inst, Dept Radiat Oncol, 460 W 10th Ave, Columbus, OH 43210 USA
[3] Dept Radiat Oncol, A201 Off F,460 W 10th Ave, Columbus, OH 43210 USA
关键词
Intrafraction motion review; Triggered imaging; Advanced imaging; Spine; Stereotactic; BODY RADIATION-THERAPY; INTRAFRACTION MOTION; CONSENSUS GUIDELINES; RESPIRATORY MOTION; METASTASES; PROSTATE; RADIOSURGERY; MANAGEMENT; CANCER; CORD;
D O I
10.1016/j.phro.2023.100422
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Mitigation of intrafraction motion (IM) is valuable in stereotactic radiotherapy (SRT) radiotherapy where submillimeter accuracy is desired. The purpose of this study was to investigate the application of triggered kilovoltage (kV) imaging for spine SRT patients with hardware by correlating kV imaging with patient motion and summarizing implications of tolerance for IM based on calculated dose.Materials and methods: Ten plans (33 fractions) were studied, correlating kV imaging during treatment with preand post-treatment cone beam computed tomography (CBCT). Images were taken at 20-degree gantry angle intervals during the arc-based treatment. The contour of the hardware with a 1 mm expansion was displayed at the treatment console to manually pause treatment delivery if the hardware was visually detected outside the contour. The treatment CBCTs were compared using retrospective image registration to assess the validity of contour-based method for pausing treatment. Finally, plans were generated to estimate dose volume objective differences in case of 1 mm deviation.Results: When kV imaging during treatment was used with the 1 mm contour, 100 % of the post-treatment CBCTs reported consistent results. One patient in the cohort exhibited motion greater than 1 mm during treatment which allowed intervention and re-setup during treatment. The average translational motion was 0.35 mm. Treatment plan comparison at 1 mm deviation showed little differences in calculated dose for the target and cord.Conclusions: Utilizing kV imaging during treatment is an effective method of assessing IM for SRT spine patients with hardware without increasing treatment time.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Implementation of Intrafraction Motion Review (IMR) for Stereotactic Treatment of the Spine for Patients with Spinal Fixation Hardware
    Cetnar, A.
    Degnan, M.
    Pichler, J.
    Jain, S.
    Morelli, S.
    MEDICAL PHYSICS, 2022, 49 (06) : E389 - E390
  • [2] Clinical Implementation and Utility of Triggered kV Imaging During Spine Stereotactic Body Radiotherapy for Intrafraction Motion Management
    Koo, J.
    Nardella, L.
    Degnan, M.
    Andreozzi, J.
    Yu, H. H. M.
    Penagaricano, J. A.
    Johnstone, P. A. S.
    Oliver, D. E.
    Ahmed, K. A.
    Rosenburg, S.
    Wuthrick, E. J.
    Diaz, R.
    Feygelman, V.
    Moros, E. G.
    Redler, G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E554 - E555
  • [3] Use of Kilovoltage Triggered Imaging for Motion Management in Stereotactic Ablative
    Rostamzadeh, Maryam
    Rathod, Shrinivas
    Sharieff, Waseem
    Hsu, Fred H. C.
    Atwal, Parmveer
    Mathews, Lindsay
    MEDICAL PHYSICS, 2024, 51 (08) : 5809 - 5809
  • [4] Update on Imaging of Spinal Fixation Hardware
    Winegar, Blair A.
    Kay, Matthew D.
    Chadaz, Tyson S.
    Taljanovic, Mihra S.
    Hood, Kenneth A.
    Hunter, Tim B.
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2019, 23 (02) : E56 - E79
  • [5] IMAGING FOR STEREOTACTIC SPINE RADIOTHERAPY: CLINICAL CONSIDERATIONS
    Dahele, Max
    Zindler, Jaap D.
    Sanchez, Esther
    Verbakel, Wilko F.
    Kuijer, Joost P. A.
    Slotman, Ben J.
    Senan, Suresh
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : 321 - 330
  • [6] Effect of spine hardware on small spinal stereotactic radiosurgery dosimetry
    Wang, Xin
    Yang, James N.
    Li, Xiaoqiang
    Tailor, Ramesh
    Vassilliev, Oleg
    Brown, Paul
    Rhines, Laurence
    Chang, Eric
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (19): : 6733 - 6747
  • [7] Evaluation of the Effect of Spine Hardware for CyberKnife Spinal Stereotactic Radiosurgery
    Yuan, J.
    Zhang, Y.
    Zheng, Y.
    Wessels, B.
    Machtay, M.
    Yao, M.
    Lo, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3426 - 3427
  • [8] Implementation and validation of a new fixation system for stereotactic radiotherapy
    Lang, S.
    Linsenmeier, C.
    Brown, M. L.
    Tini, A.
    Cavelaars, F.
    Winter, C.
    Krayenbuehl, J.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S702 - S702
  • [9] Imaging of Current Spinal Hardware: Lumbar Spine
    Ha, Alice S.
    Petscavage-Thornas, Janelle M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (03) : 573 - 581
  • [10] SPINAL FIXATION .2. FIXATION TECHNIQUES AND HARDWARE FOR THE THORACIC AND LUMBOSACRAL SPINE
    SLONE, RM
    MACMILLAN, M
    MONTGOMERY, WJ
    HEARE, M
    RADIOGRAPHICS, 1993, 13 (03) : 521 - 543