Effect of Thermal Cycling on the Flexural Strength and Hardness of New-Generation Denture Base Materials

被引:26
|
作者
Cakmak, Gulce [1 ]
Doenmez, Mustafa Borga [1 ,2 ]
Akay, Canan [3 ,4 ]
Abou-Ayash, Samir [1 ]
Schimmel, Martin [1 ,5 ]
Yilmaz, Burak [1 ,6 ,7 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3010 Bern, Switzerland
[2] Istinye Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey
[3] Osmangazi Univ, Fac Dent, Dept Prosthodont, Eskisehir, Turkey
[4] Osmangazi Univ, Translat Med Res & Clin Ctr, Eskisehir, Turkey
[5] Univ Geneva, Univ Clin Dent Med, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland
[6] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland
[7] Ohio State Univ, Div Restorat & Prosthet Dent, Coll Dent, Columbus, OH USA
关键词
Additive manufacturing; denture base; flexural strength; microhardness; thermal cycling; GRAPHENE; PMMA;
D O I
10.1111/jopr.13615
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To evaluate the flexural strength and Vickers microhardness of different CAD-CAM denture base materials. Materials and methods Sixty rectangular specimens (64 x 10 x 3.3 +/- 0.2 mm) were fabricated from 3 different denture base materials (G-CAM, Graphene-reinforced polymethylmethacrylate, GC), Ivotion Base (Prepolymerized polymethylmethacrylate, IV), and Denturetec (3D-printed resin, DT) either by using additive (DT) or subtractive manufacturing (IV and GC). Specimens of each group were divided into 2 subgroups (thermal cycled or nonthermal cycled, n = 10/group). Nonthermal cycled specimens were stored in distilled water at 37 degrees C for 24 hours and subjected to 3-point flexural strength test with a universal testing machine. Thermal cycled specimens were initially evaluated for Vickers microhardness and subjected to thermal cycling (10,000 cycles at 5-55 degrees C). Vickers microhardness values were remeasured, and the specimens were subjected to 3-point flexural strength test. Data were analyzed by using 2-way analysis of variance and Bonferroni-corrected Tukey honestly significant difference tests (alpha = 0.05). Results Material type and condition significantly affected flexural strength (p <= 0.004), whereas their interaction was nonsignificant (p = 0.778). Overall flexural strength of the materials in decreasing order was GC, IV, and DT (p < 0.001), regardless of the condition. Material had a higher effect on flexural strength (eta p(2) = 0.731) than thermal cycling (eta p(2) = 0.142). The effect of the interaction between the material type and thermal cycling on Vickers microhardness was significant (p < 0.001). GC had the highest microhardness before and after thermal cycling (p < 0.001). IV had higher microhardness than DT before thermal cycling (p < 0.001). However, DT and IV showed similar microhardness after thermal cycling (p = 0.665). Thermal cycling decreased the microhardness of GC and IV (p <= 0.022), whereas its effect on DT's microhardness was nonsignificant (p = 0.538). Material type had the highest effect on microhardness (eta p(2) = 0.864) followed by the interaction between the main factors (eta p(2) = 0.258). Conclusions Graphene-reinforced polymethylmethacrylate had the highest flexural strength and Vickers microhardness values, regardless of thermal cycling. Thermal cycling reduced the flexural strength of all resins. Thermal cycling reduced the microhardness of milled polymethylmethacrylate, but not that of 3D-printed resin.
引用
收藏
页码:81 / 86
页数:6
相关论文
共 50 条
  • [21] Effect of repair methods and materials on the flexural strength of 3D-printed denture base resin
    Viotto, Hamile Emanuella do Carmo
    Silva, Marcela Dantas Dias
    Nunes, Thais Soares Bezerra Santos
    Coelho, Sabrina Romao Goncalves
    Pero, Ana Carolina
    JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (05): : 305 - 314
  • [22] Flexural strength at the proportional limit of a denture base material relined with four different denture reline materials
    Takahashi, Y
    Kawaguchi, M
    Chai, J
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 1997, 10 (06) : 508 - 512
  • [23] Effect of thermal cycling on denture base and autopolymerizing reline resins
    Silva, Cintia de Souza
    Machado, Ana Lucia
    Lima Chaves, Carolina de Andrade
    Pavarina, Ana Claudia
    Vergani, Carlos Eduardo
    JOURNAL OF APPLIED ORAL SCIENCE, 2013, 21 (03) : 219 - 224
  • [24] Flexural strength of repaired denture base materials manufactured for the CAD-CAM technique
    Ozatik, Sebnem
    Alan, Canan Bural
    JOURNAL OF ORAL SCIENCE, 2024, 66 (02) : 120 - 124
  • [25] The effect of thermal cycling and storage parameters on the flexural strength of provisional resin crown materials.
    Ehrenberg, D
    Weiner, S
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 180 - 180
  • [26] Effect of glass fiber reinforcement on the flexural strength of different denture base resins
    Aydin, C
    Yilmaz, H
    Çaglar, A
    QUINTESSENCE INTERNATIONAL, 2002, 33 (06): : 457 - 463
  • [27] HARDNESS AND STRENGTH PROPERTIES OF A NEW HIGH-IMPACT DENTURE BASE RESIN
    LEONG, A
    HARCOURT, JK
    JOURNAL OF DENTAL RESEARCH, 1974, 53 (03) : 709 - 709
  • [28] Effect of zinc oxide nanoparticles on the flexural strength of polymethylmethacrylate denture base resin
    Vikram, Santhanam
    Chander, N. Gopi
    EUROPEAN ORAL RESEARCH, 2020, 54 (01) : 31 - 35
  • [29] Effect of HNTs and CNNTs Nanotubes on the Impact Strength and Hardness of PMMA Denture Base
    Aldwimi, Issam M.
    Alhareb, Ahmed O.
    Akil, Hazizan Md
    4TH INTERNATIONAL SCIENCES, TECHNOLOGY AND ENGINEERING CONFERENCE (ISTEC) 2020: EXPLORING MATERIALS FOR THE FUTURE, 2021, 2332
  • [30] Effect of thermal cycling and disinfection on microhardness of acrylic resin denture base
    Goiato, Marcelo Coelho
    Dos Santos, Daniela Micheline
    Baptista, Gabriella Trunckle
    Moreno, Amália
    Andreotti, Agda Marobo
    Dekon, Stéfan Fiuza De Carvalho
    Journal of Medical Engineering and Technology, 2013, 37 (03): : 203 - 207