Development and validation of a sensitive and simple LC-MS/MS method for simultaneous quantitation of valsartan, sacubitril and sacubitrilat in pediatric population

被引:2
|
作者
Yang, Quancheng [1 ,2 ]
Cao, Peng [1 ,2 ,3 ,4 ]
Lv, Yi [1 ,2 ]
Peng, Hua [5 ]
Zhai, Xuejia [1 ,2 ]
机构
[1] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Pharm, Wuhan 430022, Peoples R China
[2] Hubei Prov Clin Res Ctr Precis Med Crit Illness, Wuhan 430022, Peoples R China
[3] Hubei Univ Med, Sch Pharmaceut Sci, Hubei Key Lab Wudang Local Chinese Med Res, Shiyan 442000, Hubei, Peoples R China
[4] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Hubei Key Lab Biol Targeted Therapy, Wuhan, Peoples R China
[5] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Pediat, Wuhan 430022, Peoples R China
关键词
Sacubitril; Valsartan; LC-MS/MS; Pediatric patients; Therapeutic drug monitoring; RECEPTOR-NEPRILYSIN INHIBITOR; HEART-FAILURE; LCZ696; PHARMACOKINETICS; LIVER;
D O I
10.1016/j.jpba.2023.115829
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pediatric heart failure (HF) is an important clinical disease with high hospitalization rates, morbidity, mortality and medical costs. Sacubitril/valsartan (also known as Entresto), was approved for the treatment of adult HF and is recently used in pediatrics. However, clinical therapy on children is more challenging than adults, and the pharmacokinetics of Entresto in children are still largely unknown and urgently needed. Herein, we aim to develop a simple and sensitive analytic method to monitor Entresto in pediatric patients, which is of great importance for individualized safe medication in children. Specifically, a liquid chromatography tandem mass spectrometry method for simultaneously quantification of valsartan, sacubitril and its bio-active metabolite sacubitrilat in human plasma has been developed and validated in pediatric patients. Plasma samples were pretreated with acetonitrile for protein precipitation. Elution was performed on X Select HSS T3 column (2.1 x 100 mm, 5 mu m; Waters) column using an isocratic mobile phase process consisting of 0.1% formic acid aqueous solution and 0.1% formic acid acetonit rile with a total run time of 3.0 min. Valsartan-d3, sacubitrilin-d4 and sacubitrilat-d4 were used as the corresponding deuterium internal standards. According to the Bioanalytical Method Validation Guidance for Industry, the method was validated in the range of 0.5-5000 ng/mL. Intra- and inter-day accuracy of sacubitril,valsartan and sacubitrilat ranged from 93%- 108%, 98%- 109%, 91%- 102%, respectively, with relative standard deviation of precision ranging from 2.0% to 5.1%, 2.4%- 7.5%, 1,3%7.4%. The proposed method demonstrated good accuracy, precision and linearity. The matrix factors normalized by internal standard meet the acceptance criteria. The method was fully validated and applied in 39 children. Trough concentration of the three substances to be measured were: valsartan (11.3-938.0 ng/mL), sacubitril (0.5-395.5 ng/mL) and sacubitrilat (522.1-4890.0 ng/mL). Overall, this is the first study to simultaneously determined the plasma valsartan, sacubitril and sacubitrilat concentrations in children, which is believed to facilitate the clinical management of pediatric HF.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] METHOD DEVELOPMENT AND VALIDATION FOR THE QUANTITATION OF TRIFLURIDINE IN HUMAN PLASMA BY USING LC-MS/MS TECHNIQUE
    Mohammad, Abdul Saleem
    Ahmad, Fazil
    Jayanthi, B.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2020, 11 (07): : 3252 - 3259
  • [22] Development and validation of a LC-MS/MS method for the quantitation of lumefantrine in mouse whole blood and plasma
    Govender, Katya
    Gibhard, Liezl
    Du Plessis, Lissinda
    Wiesner, Lubbe
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 985 : 6 - 13
  • [23] Development and validation of a sensitive and robust LC-MS/MS with electrospray ionization method for simultaneous quantitation of quetiapine and its active metabolite norquetiapine in human plasma
    Xiong, Xin
    Yang, Li
    Duan, Jingli
    CLINICA CHIMICA ACTA, 2013, 423 : 69 - 74
  • [24] Development and validation of a highly sensitive LC-MS/MS method for simultaneous quantitation of ethionamide and ethionamide sulfoxide in human plasma: application to a human pharmacokinetic study
    Deshpande, Abhijeet Y.
    Gurav, Sandip
    Punde, Ravindra
    Zambre, Vishal
    Kulkarni, Rahul
    Pandey, Sarvesh
    Mungantiwar, Ashish
    Mullangi, Ramesh
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (09) : 985 - 994
  • [25] Development and validation of a sensitive LC-MS/MS method for the estimation of scopolamine in human serum
    Swaminathan, Suresh Kumar
    Fisher, James
    Brogden, Nicole K.
    Kandimalla, Karunya K.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 164 : 41 - 46
  • [26] An LC-MS/MS method for the simultaneous quantitation of sulfasalazine and sulfapyridine in human placenta
    Louw, Vanessa
    Brownfoot, Fiona
    Cluver, Catherine
    Decloedt, Eric
    Kellermann, Tracy
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 235
  • [27] Development of a Rapid and Sensitive LC-MS/MS Assay for Dolutegravir Quantitation in Breastmilk
    Rackow, A. R.
    Pandey, A.
    Marzinke, M. A.
    CLINICAL CHEMISTRY, 2024, 70 : I205 - I205
  • [28] Method development and validation for simultaneous quantitation of ivermectin, doramectin and moxidectin in muscle by using LC-MS/MS in positive ESI mode
    Dahiya, Meenakshi
    Dubey, Nidhi
    Singh, Prabha
    Singh, G. N.
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2015, 22 (1-2) : 26 - 33
  • [29] Development and validation of a sensitive LC-MS/MS method with electrospray ionization for quantitation of rhein in human plasma: application to a pharmacokinetic study
    Layek, Buddhadev
    Kumar, T. Santosh
    Trivedi, Ravi Kumar
    Mullangi, Ramesh
    Srinivas, Nuggehally R.
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (06) : 616 - 624
  • [30] Development and Validation of a Sensitive LC-MS/MS Method for the Simultaneous Analysis of Three-Tropane Alkaloids in Blood and Urine
    Dong, Xiaoru
    Liu, Wei
    Shen, Min
    ANALYTICAL LETTERS, 2013, 46 (01) : 18 - 28