Implantable Defibrillator System Shock Function, Mortality, and Cause of Death After Magnetic Resonance Imaging

被引:0
|
作者
Ra, Joshua [1 ,6 ]
Oberdier, Matt T. T. [2 ]
Suzuki, Masahito [2 ]
Vaidya, Dhananjay [2 ]
Liu, Yisi [3 ]
Hansford, Rozann [2 ]
McVeigh, Diana [2 ]
Weltin, Valeria [2 ]
Tao, Susumu [2 ]
Thiemann, David R. [2 ]
Nazarian, Saman [4 ]
Halperin, Henry R. [5 ]
机构
[1] Univ Calif San Francisco, Dept Med, San Francisco, CA 94143 USA
[2] Johns Hopkins Univ, Dept Cardiol, Baltimore, MD USA
[3] Johns Hopkins Univ, Dept Pediat, Baltimore, MD USA
[4] Univ Penn Perelman, Sch Med, Dept Cardiol, Philadelphia, PA USA
[5] Johns Hopkins Univ, Dept Cardiol, Dept Radiol & Biomed Engn, Baltimore, MD USA
[6] Univ Calif San Francisco, Dept Med, 521 Parnassus Ave, San Francisco, CA 94143 USA
基金
美国国家卫生研究院;
关键词
INDUSTRY VIEWPOINT; SAFE PERFORMANCE; CARDIOVERTER-DEFIBRILLATORS; CLINICAL SAFETY; ABSORPTION RATE; PACEMAKERS; MRI; ICDS; PROTOCOL; DEVICES;
D O I
10.7326/M22-2653
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Studies have shown that magnetic resonance imaging (MRI) does not have clinically important effects on the device parameters of non-MRI-conditional implantable cardioverter-defibrillators (ICDs). However, data on non-MRI-conditional ICD detection and treatment of arrhythmias after MRI are limited.Objective: To examine if non-MRI-conditional ICDs have preserved shock function of arrhythmias after MRI.Design: Prospective cohort study. (ClinicalTrials.gov: NCT01130896)Setting: 1 center in the United States.Patients: 629 patients with non-MRI-conditional ICDs enrolled consecutively between February 2003 and January 2015.Interventions: 813 total MRI examinations at a magnetic field strength of 1.5 Tesla using a prespecified safety protocol.Measurements: Implantable cardioverter-defibrillator inter-rogations were collected after MRI. Clinical outcomes included arrhythmia detection and treatment, generator or lead exchanges, adverse events, and death.Results: During a median follow-up of 2.2 years from MRI to latest available ICD interrogation before generator or lead exchange in 536 patients, 4177 arrhythmia episodes were detected, and 97 patients received ICD shocks. Sixty-one patients (10% of total) had 130 spontaneous ventricular tachycardia or fibrillation events terminated by ICD shocks. A total of 210 patients (33% of total) are known to have died (median, 1.7 years from MRI to death); 3 had cardiac arrhythmia deaths where shocks were indicated without direct evidence of device dysfunction.Limitations: Data were acquired at a single center and may not be generalizable to other clinical settings and MRI facilities. Implantable cardioverter-defibrillator interrogations were not avail-able for a subset of patients; adjudication of cause of death relied solely on death certificate data in a subset.Conclusion: Non-MRI-conditional ICDs appropriately treated detected tachyarrhythmias after MRI. No serious adverse effects on device function were reported after MRI.
引用
收藏
页码:289 / 297
页数:10
相关论文
共 50 条
  • [41] Accuracy of Magnetic Resonance Imaging (MRI) in determining cause of death: A potential alternative to the autopsy?
    Roberts, ISD
    Benbow, EW
    Bissett, R
    Jenkins, JPR
    Lee, SH
    Reid, H
    Jackson, A
    JOURNAL OF PATHOLOGY, 2000, 192 : 9A - 9A
  • [42] Left atrial volume and function measured by cardiac magnetic resonance imaging as predictors of shocks and mortality in patients with implantable cardioverter-defibrillators
    Gong, Inna Y.
    Yazdan-Ashoori, Payam
    Jimenez-Juan, Laura
    Tan, Nigel S.
    Angaran, Paul
    Chacko, Binita Riya
    Al-Mousawy, Saif
    Singh, Sheldon M.
    Shalmon, Tamar
    Folador, Luciano
    Mangat, Iqwal
    Deva, Djeven P.
    Yan, Andrew T.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (07): : 2259 - 2267
  • [43] Comparison of conventional autopsy and magnetic resonance imaging in determining the cause of sudden death in the young
    Puranik, Rajesh
    Gray, Belinda
    Lackey, Helen
    Yeates, Laura
    Parker, Geoffrey
    Duflou, Johan
    Semsarian, Christopher
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
  • [44] Comparison of conventional autopsy and magnetic resonance imaging in determining the cause of sudden death in the young
    Rajesh Puranik
    Belinda Gray
    Helen Lackey
    Laura Yeates
    Geoffrey Parker
    Johan Duflou
    Christopher Semsarian
    Journal of Cardiovascular Magnetic Resonance, 16
  • [45] Left atrial volume and function measured by cardiac magnetic resonance imaging as predictors of shocks and mortality in patients with implantable cardioverter-defibrillators
    Inna Y. Gong
    Payam Yazdan-Ashoori
    Laura Jimenez-Juan
    Nigel S. Tan
    Paul Angaran
    Binita Riya Chacko
    Saif Al-Mousawy
    Sheldon M. Singh
    Tamar Shalmon
    Luciano Folador
    Iqwal Mangat
    Djeven P. Deva
    Andrew T. Yan
    The International Journal of Cardiovascular Imaging, 2021, 37 : 2259 - 2267
  • [46] Dynamic magnetic resonance imaging of muscle function after surgery
    Asakawa, Deanna S.
    Blemker, Silvia S.
    Gold, Garry E.
    Delp, Scott L.
    SKELETAL RADIOLOGY, 2006, 35 (12) : 885 - 886
  • [47] Dynamic magnetic resonance imaging of muscle function after surgery
    Deanna S. Asakawa
    Silvia S. Blemker
    Garry E. Gold
    Scott L. Delp
    Skeletal Radiology, 2006, 35 : 885 - 886
  • [48] The Effect of Renal Function on Survival After Implantable Cardioverter Defibrillator Placement
    Hager, Casey S.
    Blackwell, Jeffrey
    Jain, Sunil
    Culp, Benjamin
    Davis, Elaine
    Hanlon, Charin
    Chiles, Christopher D.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A134 - A134
  • [49] Magnetic resonance imaging (MRI) for non-invasive analysis of hepatic function after hemorrhagic shock in the rat
    Maier M.
    Hahn P.
    Schneider G.
    Marzi I.
    European Journal of Trauma, 2006, 32 (5): : 449 - 455
  • [50] Implantable defibrillator after myocardial infarction in patients with high risk rhythmic mortality
    Juliard, Jean-Michel
    SANG THROMBOSE VAISSEAUX, 2010, 22 (01): : 8 - 9