Levofloxacin dry powder inhaler for high dose delivery

被引:3
|
作者
Ceschan, Nazareth Eliana [1 ,2 ]
Bucala, Veronica [1 ,3 ]
Ramirez-Rigo, M. Veronica [1 ,2 ]
机构
[1] Univ Nacl Sur UNS, Planta Piloto Ingn Quim PLAPIQUI, CONICET, Camino Carrindanga Km 7, RA-8000 Bahia Blanca, Argentina
[2] UNS, Dept Biol Bioquim & Farm, San Juan 670, RA-8000 Bahia Blanca, Argentina
[3] UNS, Dept Ingn Quim, Ave Alem 1253, RA-8000 Bahia Blanca, Argentina
关键词
Antibiotics; Aerodynamic performance; Cystic fibrosis; Dry powder inhaler; Inhalation; Excipient-free; INSPIRATORY FLOW-RATE; AEROSOLIZATION BEHAVIOR; ATENOLOL MICROPARTICLES; DRUG-DELIVERY; PERFORMANCE; CIPROFLOXACIN; DEHYDRATION; FORMULATION; INHALATION; PARTICLES;
D O I
10.1016/j.powtec.2023.119168
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Mucous plugs in the respiratory system of cystic fibrosis patients are often infected, typically by Pseudomonas aeruginosa. Nebulized levofloxacin is effective against P. aeruginosa, but the administration and cleaning process is time-consuming. To address this limitation, dry powder inhalers are a potential alternative if a high required dose could be loaded. The objective of this study was to develop and characterize an excipient-free levofloxacin powder produced by a solvent-free spray drying method. The obtained particles were small, rounded and crystalline. Under pharmacopoeial impactor conditions, high emitted, fine particle and respirable fractions were achieved, even with high drug loadings. Variations in the impactor pump's air flowrate did not significantly affect the aerodynamic performance. After 12 months' storage critical attributes remained largely unchanged. The developed system allows for the same dose delivery as the marketed product for nebulization using only four capsules, highlighting its potential in cystic fibrosis treatments.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] A NEW DRY POWDER INHALER
    POVER, GM
    BROWNING, AK
    MULLINGER, BM
    BUTLER, AG
    DASH, CH
    PRACTITIONER, 1982, 226 (1365) : 565 - 567
  • [42] Quality Assurance Test of Delivered Dose Uniformity of Multiple-Dose Inhaler and Dry Powder Inhaler Drug Products
    Tsong, Yi
    Dong, Xiaoyu
    Shen, Meiyu
    Lostritto, Richard T.
    JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2015, 25 (02) : 328 - 338
  • [43] Co-Delivery of a High Dose of Amphotericin B and Itraconazole by Means of a Dry Powder Inhaler Formulation for the Treatment of Severe Fungal Pulmonary Infections
    Celi, Salome S.
    Fernandez-Garcia, Raquel
    Afonso-Urich, Andreina I.
    Ballesteros, M. Paloma
    Healy, Anne Marie
    Serrano, Dolores R.
    PHARMACEUTICS, 2023, 15 (11)
  • [44] The effect of flow rate on drug delivery from the pulvinal, a high-resistance dry powder inhaler
    Meakin, BJ
    Ganderton, D
    Panza, I
    Ventura, P
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1998, 11 (03): : 143 - 152
  • [45] IMPROVING PHYSICAL AND AEROSOL STABILITY OF SPRAY DRIED HIGH-DOSE DRY POWDER INHALER FORMULATIONS
    Encinas-Basurto, David
    McCombs, Kiley
    Vallorz, Ernest
    Mansour, Heidi
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2022, 35 (02) : A5 - A5
  • [46] Characterization of a New High-Dose Dry Powder Inhaler (DPI) Based on a Fluidized Bed Design
    Dale R. Farkas
    Michael Hindle
    P. Worth Longest
    Annals of Biomedical Engineering, 2015, 43 : 2804 - 2815
  • [47] IMPROVING PHYSICAL AND AEROSOL STABILITY OF SPRAY DRIED HIGH-DOSE DRY POWDER INHALER FORMULATIONS
    Shetty, Nivedita
    Park, Heejun
    Zemlyanov, Dmitry
    Cavallaro, Alex
    Mangal, Sharad
    Zhou, Qi
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2019, 32 (03) : A15 - A16
  • [48] Importance of Powder Residence Time for the Aerosol Delivery Performance of a Commercial Dry Powder Inhaler Aerolizer®
    Jiang, Liqun
    Tang, Yue
    Zhang, Hongjiu
    Lu, Xifeng
    Chen, Xijing
    Zhu, Jiabi
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2012, 25 (05) : 265 - 279
  • [49] Characterization of a New High-Dose Dry Powder Inhaler (DPI) Based on a Fluidized Bed Design
    Farkas, Dale R.
    Hindle, Michael
    Longest, P. Worth
    ANNALS OF BIOMEDICAL ENGINEERING, 2015, 43 (11) : 2804 - 2815
  • [50] Improved Lung Delivery from a Passive Dry Powder Inhaler Using an Engineered PulmoSphere® Powder
    Sarma P. Duddu
    Steven A. Sisk
    Yulia H. Walter
    Thomas E. Tarara
    Kevin R. Trimble
    Andrew R. Clark
    Michael A. Eldon
    Rebecca C. Elton
    Matthew Pickford
    Peter H. Hirst
    Stephen P. Newman
    Jeffry G. Weers
    Pharmaceutical Research, 2002, 19 : 689 - 695