Dosimetric Impact of Setup Errors in Single-Isocenter VMAT Radiosurgery for Brain Metastases

被引:0
|
作者
Faccenda, V. [1 ]
Panizza, D. [1 ]
Trivellato, S. [1 ]
Daniotti, M. C. [1 ]
Pisoni, V. [2 ]
Lucchini, R. [3 ]
Arcangeli, S. [3 ]
De Ponti, E. [1 ]
机构
[1] Fdn IRCCS San Gerardo dei Tintori, Med Phys Dept, Monza, Italy
[2] Fdn IRCCS San Gerardo dei Tintori, Radiat Oncol Dept, Monza, Italy
[3] Univ Milano Bicocca, Sch Med & Surg, Milan, Italy
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
2225
引用
收藏
页码:E102 / E103
页数:2
相关论文
共 50 条
  • [41] Dosimetric Evaluation of Two Modern Planning Techniques for Single-Isocenter, Multiple Brain Metastases Fractionated-Stereotactic Radiosurgery with >20 Lesions
    Jung, H.
    Yoon, J.
    Milano, M.
    Usuki, K.
    Hardy, S.
    Zheng, D.
    MEDICAL PHYSICS, 2022, 49 (06) : E960 - E960
  • [42] Single-isocenter stereotactic radiosurgery for multiple brain metastases: Impact of patient misalignments on target coverage in non-coplanar treatments
    Eder, Michael Martin
    Reiner, Michael
    Heinz, Christian
    Garny, Sylvia
    Freislederer, Philipp
    Landry, Guillaume
    Niyazi, Maximilian
    Belka, Claus
    Riboldi, Marco
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2022, 32 (03): : 296 - 311
  • [43] Dosimetric validation for an automatic brain metastases planning software using single-isocenter dynamic conformal arcs
    Liu, Haisong
    Li, Jun
    Pappas, Evangelos
    Andrews, David
    Evans, James
    Werner-Wasik, Maria
    Yu, Yan
    Dicker, Adam
    Shi, Wenyin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05): : 142 - 156
  • [44] Modeling Dosimetric Distributions for Brain Stereotactic Radiosurgery (SRS) for Single-Isocenter Multi-Target (SIMT) Treatments
    Zoller, W.
    Addington, M.
    Taylor, W.
    Sebastian, N.
    Palmer, J. D.
    Raval, R.
    DiCostanzo, D. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E91 - E91
  • [45] Dosimetric Evaluation of Single Versus Multi-isocenter Frameless Radiosurgery for Multiple Brain Metastases
    Camarata, A. S.
    Siddiqi, A. S.
    Prabhu, R. S.
    Ogunleye, T.
    Koontz-Raisig, W. G.
    Tejani, M.
    Curran, W. J.
    Crocker, I. R.
    Shu, H. G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S758 - S758
  • [46] Recommendations for Treatment Planning Dose Indices for Single-Isocenter Single Target VMAT Brain Stereotactic Radiosurgery/Radiotherapy; A Retrospective Analysis
    Pearson, D.
    Newell, D.
    Joseph, K.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [47] Single-Isocenter Frameless Volumetric Modulated Arc Radiosurgery for Multiple Intracranial Metastases
    Lau, Steven K. M.
    Zakeri, Kaveh
    Zhao, Xiao
    Carmona, Ruben
    Knipprath, Erik
    Simpson, Daniel R.
    Nath, Sameer K.
    Kim, Gwe-Ya
    Sanghvi, Parag
    Hattangadi-Gluth, Jona A.
    Chen, Clark C.
    Murphy, Kevin T.
    NEUROSURGERY, 2015, 77 (02) : 233 - 240
  • [48] Dosimetric Impact of Rotational Setup Errors on Multiple Brain Targets Treated with Single Isocenter Volumetric Modulated Arc Therapy
    Xue, J.
    No, D.
    Zhang, J.
    Wang, H.
    Barbee, D.
    Lymberis, S.
    Silverman, J.
    Das, I.
    MEDICAL PHYSICS, 2018, 45 (06) : E615 - E615
  • [49] Frameless Surface-Gated Single-Isocenter Radiosurgery: Setup Accuracy and Plan Robustness
    Puccini, S.
    Hoeft, M.
    Grossmann, U.
    Halbur, J.
    Voelzke, D.
    Semrau, R.
    Rief, H.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1456 - S1456
  • [50] Impact of MLC error on dose distribution in SRS treatment of single-isocenter multiple brain metastases: comparison between DCAT and VMAT techniques
    Katayama, Hiroki
    Kobata, Takuya
    Kitaoka, Motonori
    Takahashi, Shigeo
    Shibata, Toru
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2024, 29 (05) : 531 - 543