Multi-coil design for a coaxial double-cylinder head MRI scanner

被引:0
|
作者
Xuan, Liang [1 ]
Xu, Zheng [1 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
Electromagnetic inverse problem; Magnetic device; TARGET-FIELD METHOD;
D O I
10.1108/COMPEL-01-2022-0044
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Purpose Gradient coils designed by conventional target field methods usually have a complex physical structure and these methods are not convergent for complex routing area problems. This study aims to design a multi-coil (MC) gradient system arranged on a complex routing area including two cylindrical surfaces with different radii for a head magnetic resonance imaging scanner. Design/methodology/approach A MC system model is established. In this model, the sub-coils are evenly distributed on two cylindrical wiring surfaces, and the radii of coils are the same on one cylindrical surface. With the target magnetic field set, the currents in every individual coil are solved by constrained least-squares fitting based on the Levenberg-Marquardt method. Findings The magnetic field nonlinearity generated by designed coils is validated as 4.50% and 3.57% for X-gradient coil and Z-gradient coil, respectively, which satisfy the mainstream nonlinearity standards. The analysis of the optimization results indicates that hardware requirements can be considerably reduced by connecting coils with the same currents in series. Originality/value High-linearity gradient magnetic fields are generated on complex routing areas by adopting the MC structure. In addition, the requirements for current sources and amplifiers are considerably reduced.
引用
收藏
页码:112 / 120
页数:9
相关论文
共 50 条
  • [31] Multi-coil Approach to Mitigate the Design Limitations for Wireless Power Transfer in Biomedical Implants
    RamRakhyani, Anil Kumar
    Lazzi, Gianluca
    2014 USNC-URSI RADIO SCIENCE MEETING (JOINT WITH AP-S SYMPOSIUM), 2014, : 309 - 309
  • [32] FFVN: An explicit feature fusion-based variational network for accelerated multi-coil MRI reconstruction
    Zhang, Zhenxi
    Du, Hongwei
    Qiu, Bensheng
    MAGNETIC RESONANCE IMAGING, 2023, 97 : 31 - 45
  • [33] An inverse design of an open, head/neck RF coil for MRI
    Lawrence, BG
    Crozier, S
    Cowin, G
    Yau, DD
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (09) : 1024 - 1030
  • [34] Design of an Electrically Automated RF Transceiver Head Coil in MRI
    Sohn, Sung-Min
    DelaBarre, Lance
    Gopinath, Anand
    Vaughan, John Thomas
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2015, 9 (05) : 725 - 732
  • [35] Multi-Load Constant Voltage Design for Multi-Load and Multi-Coil Wireless Power Transfer System
    Lu W.
    Chen W.
    Li H.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2019, 34 (06): : 1137 - 1147
  • [36] Configuration Design and Efficiency Optimization of Hybrid Multi-coil for Multi-port Wireless Energy Interconnection System With Virtual Bus
    Zhou, Minghua
    Liu, Fuxin
    Chen, Xuling
    Jin, Ke
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2024, 44 (14): : 5693 - 5701
  • [37] Novel Multi-Coil Resonator Design for Wireless Power Transfer through Reinforced Concrete Structure with Rebar Array
    Jang, Yujin
    Han, Jung-Kyu
    Baek, Jae-Il
    Moon, Gun-Woo
    Kim, Ji-Min
    Sohn, Hoon
    2017 IEEE 3RD INTERNATIONAL FUTURE ENERGY ELECTRONICS CONFERENCE AND ECCE ASIA (IFEEC 2017-ECCE ASIA), 2017, : 2238 - 2243
  • [38] Accelerated imaging of rest and stress myocardial perfusion MRI using multi-coil k-t SLR: a feasibility study
    Sajan Goud Lingala
    Edward DiBella
    Mathews Jacob
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [39] A new design method for asymmetrical head gradient coils used for superconducting MRI scanner
    Tang, X
    Zu, DL
    Bao, SL
    PROGRESS IN NATURAL SCIENCE-MATERIALS INTERNATIONAL, 2004, 14 (09) : 753 - 757