Real-World Evidence of the Cambridge Hybrid Closed-Loop App With a Novel Real-Time Continuous Glucose Monitoring System

被引:3
|
作者
Newman, Christine [1 ,5 ]
Hartnell, Sara [1 ]
Wilinska, Malgorzata [2 ,3 ]
Alwan, Heba [2 ,4 ]
Hovorka, Roman [2 ,3 ]
机构
[1] Cambridge Univ Hosp NHS Fdn Trust, Addenbrookes Hosp, Wolfson Diabet & Endocrinol, Cambridge, England
[2] Univ Cambridge, Wellcome MRC Inst Metab Sci, Metab Res Labs, Cambridge, England
[3] Univ Cambridge, Dept Paediat, Cambridge, England
[4] Univ Bern, Inst Primary Hlth Care BIHAM, Bern, Switzerland
[5] Cambridge Univ Hosp NHS Fdn Trust, Addenbrookes Hosp, Wolfson Diabet & Endocrinol, Clin 32, Cambridge CB2 0QQ, England
来源
关键词
automated insulin delivery; hybrid closed loop; real world evidence; CamAPS FX; GLYCEMIC TARGETS;
D O I
10.1177/19322968231187915
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the performance of the interoperable Cambridge hybrid closed-loop app with FreeStyle Libre 3 glucose sensor, and YpsoPump insulin pump in a real-world setting. Data from 100 users (63 adults [mean & PLUSMN; SD age 41.9 & PLUSMN; 14.0 years], 15 children [8.6 & PLUSMN; 5.2 years)] and 22 users of unreported age) for a period of 28 days were analyzed. Time in range (3.91- 10.0mmol/L) was 72.6 & PLUSMN; 11.1% overall. Time below range (<3.9mmol/L) was 3.1% (1.4-5.1) (median [interquartile range]). Auto-mode was active for 95.8% (91.8-97.9) of time. This real-world analysis suggests that the performance of Cambridge hybrid closed-loop app with this glucose sensor is comparable to other commercially available hybrid closed-loop systems.
引用
收藏
页码:165 / 168
页数:4
相关论文
共 50 条
  • [21] A Closed-Loop AR-based BCI for Real-World System Control
    Gorman, Campbell
    Wang, Yu-Kai
    2021 IEEE SYMPOSIUM SERIES ON COMPUTATIONAL INTELLIGENCE (IEEE SSCI 2021), 2021,
  • [22] Is Continuous Glucose Monitoring Effective? Evidence from Real-World Data
    Zheng, Yaguang
    Siminerio, Linda M.
    Anton, Bonnie
    Krall, Jodi T.
    Bednarz, Lori L.
    Li, Dan
    Ng, Jason
    DIABETES, 2020, 69
  • [23] A Multimodal Drowsiness Monitoring Ear-Module System with Closed-Loop Real-Time Alarm
    Ha, Unsoo
    Yoo, Hoi-Jun
    PROCEEDINGS OF 2016 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2016, : 536 - 539
  • [24] Closed-loop testing with the real-time digital power system simulator
    Marttila, RJ
    Dick, EP
    Fischer, D
    Mulkins, CS
    ELECTRIC POWER SYSTEMS RESEARCH, 1996, 36 (03) : 181 - 190
  • [25] Identification of closed-loop system based on real-time genetic algorithm
    Li, HX
    ICEMI 2005: CONFERENCE PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL 2, 2005, : 253 - 256
  • [26] Real-World Pediatric Outcomes of Hybrid Closed-Loop Systems at a Large Urban Center
    Tillotson, Cara V.
    Nichols, Presley H.
    Mofford, Kaisha
    Leibel, Natasha
    Gandica, Rachelle
    DIABETES, 2023, 72
  • [27] Hard real-time closed-loop electrophysiology with the Real-Time eXperiment Interface (RTXI)
    Patel, Yogi A.
    George, Ansel
    Dorval, Alan D.
    White, John A.
    Christini, David J.
    Butera, Robert J.
    PLOS COMPUTATIONAL BIOLOGY, 2017, 13 (05)
  • [28] Robust closed-loop dynamic real-time optimization
    MacKinnon, Lloyd
    Swartz, Christopher L. E.
    JOURNAL OF PROCESS CONTROL, 2023, 126 : 12 - 25
  • [29] A closed-loop real-time infrared scene generator
    Crow, DR
    Coker, CF
    Garbo, DL
    Olson, EM
    TECHNOLOGIES FOR SYNTHETIC ENVIRONMENTS: HARDWARE-IN-THE-LOOP TESTING III, 1998, 3368 : 342 - 351
  • [30] A REAL-TIME CLOSED-LOOP CONTROLLER FOR SECURITY DISPATCH
    KUMAR, DV
    RAJU, VV
    KUPPURAJULU, A
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 1993, 15 (05) : 307 - 313