Fast-spin-echo versus rapid gradient-echo for 3D magnetization-prepared acquisitions: Application to inhomogeneous magnetization transfer

被引:1
|
作者
Taso, Manuel [1 ,2 ]
Munsch, Fanny [1 ,2 ]
Girard, Olivier M. [3 ]
Duhamel, Guillaume [3 ]
Alsop, David C. [1 ,2 ]
Varma, Gopal [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Div MRI Res, 330 Brookline Ave,Ansin 244, Boston, MA 02215 USA
[2] Harvard Med Sch, Boston, MA 02115 USA
[3] Aix Marseille Univ, CNRS, CRMBM, Marseille, France
关键词
fast-spin-echo; inhomogeneous magnetization transfer; myelin imaging; signal-to-noise; volumetric imaging; BROADENED LINES IHMT; SENSITIVITY; IMAGE; MRI; T-1; RELAXATION; PULSES;
D O I
10.1002/mrm.29461
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To evaluate the benefits of fast spin echo (FSE) imaging over rapid gradient-echo (RAGE) for magnetization-prepared inhomogeneous magnetization transfer (ihMT) imaging. Methods A 3D FSE sequence was modified to include an ihMT preparation (ihMT-FSE) with an optional CSF suppression based on an inversion-recovery (ihMT-FLAIR). After numeric simulations assessing SNR benefits of FSE and the potential impact of an additional inversion-recovery, ihMT-RAGE, ihMT-FSE, and ihMT-FLAIR sequences were compared in a group of six healthy volunteers, evaluating image quality, thermal, and physiological noise as well as quantification using an ihMT saturation (ihMTsat) approach. A preliminary exploration in the cervical spinal cord was also conducted in a group of three healthy volunteers. Results Several fold improvements in thermal SNR were observed with ihMT-FSE in agreement with numerical simulations. However, we observed significantly higher physiological noise in ihMT-FSE compared to ihMT-RAGE that was mitigated in ihMT-FLAIR, which provided the best total SNR (+74% and +49% compared to ihMT-RAGE in the white and gray matter, P <= 0.004). IhMTsat quantification was successful in all cases with strong correlation between all sequences (r(2) > 0.75). Early experiments showed potential for spinal cord imaging. Conclusions FSE generally offers higher SNR compared to gradient-echo based acquisitions for magnetization-prepared contrasts as illustrated here in the case of ihMT. However, physiological noise has a significant effect, but an inversion-recovery-based CSF suppression was shown to be efficient in mitigating effects of CSF motion.
引用
收藏
页码:550 / 564
页数:15
相关论文
共 50 条
  • [31] Associations of High Intensities on Magnetization-Prepared Rapid Acquisition with Gradient Echo with Aortic Complicated Lesions in Ischemic Stroke Patients
    Yamaguchi, Yoshitaka
    Tanaka, Tomotaka
    Morita, Yoshiaki
    Yoshimura, Sohei
    Koga, Masatoshi
    Ihara, Masafumi
    Toyoda, Kazunori
    CEREBROVASCULAR DISEASES, 2019, 47 (1-2) : 15 - 23
  • [32] SHAPING THE SIGNAL RESPONSE DURING THE APPROACH TO STEADY-STATE IN 3-DIMENSIONAL MAGNETIZATION-PREPARED RAPID GRADIENT-ECHO IMAGING USING VARIABLE FLIP ANGLES
    MUGLER, JP
    EPSTEIN, FH
    BROOKEMAN, JR
    MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) : 165 - 185
  • [33] Fast High-Resolution 3D Magnetization-Prepared GRE with Complementary Phase-Cycling Acquisitions
    Peng, Q.
    Zhao, Y.
    Wu, C.
    MEDICAL PHYSICS, 2022, 49 (06) : E144 - E144
  • [34] Semi-automatic carotid intraplaque hemorrhage detection and quantification on Magnetization-Prepared Rapid Acquisition Gradient-Echo (MP-RAGE) with optimized threshold selection
    Jin Liu
    Niranjan Balu
    Daniel S. Hippe
    Marina S. Ferguson
    Vanesa Martinez-Malo
    J. Kevin DeMarco
    David C. Zhu
    Hideki Ota
    Jie Sun
    Dongxiang Xu
    William S. Kerwin
    Thomas S. Hatsukami
    Chun Yuan
    Journal of Cardiovascular Magnetic Resonance, 18
  • [35] Pelvic adenopathy in prostatic and urinary bladder carcinoma: MR imaging with a three-dimensional TI-weighted magnetization-prepared rapid gradient-echo sequence
    Jager, GJ
    Barentsz, JO
    Oosterhof, GO
    Witjes, JA
    Ruijs, SJH
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (06) : 1503 - 1507
  • [36] Semi-automatic carotid intraplaque hemorrhage detection and quantification on Magnetization-Prepared Rapid Acquisition Gradient-Echo (MP-RAGE) with optimized threshold selection
    Liu, Jin
    Balu, Niranjan
    Hippe, Daniel S.
    Ferguson, Marina S.
    Martinez-Malo, Vanesa
    DeMarco, J. Kevin
    Zhu, David C.
    Ota, Hideki
    Sun, Jie
    Xu, Dongxiang
    Kerwin, William S.
    Hatsukami, Thomas S.
    Yuan, Chun
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18
  • [37] MRI OF THE PITUITARY-GLAND - SPIN-ECHO 2D OR GRADIENT-ECHO 3D
    REUTHER, G
    BONGARTZ, G
    FAHRENDORF, G
    PETERS, PE
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 154 (03): : 281 - 285
  • [38] High-Resolution Magnetic Resonance Imaging of the Inferior Alveolar Nerve Using 3-Dimensional Magnetization-Prepared Rapid Gradient-Echo Sequence at 3.0T
    Deng, Wei
    Chen, Song-Ling
    Zhang, Zhong-Wei
    Huang, Dai-Ying
    Zhang, Xing
    Li, Xiang
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 66 (12) : 2621 - 2626
  • [39] Spin-echo and 3D gradient-echo imaging of the knee joint: A clinical and histopathological comparison
    Guckel, C
    Jundt, G
    Schnabel, K
    Gachter, A
    EUROPEAN JOURNAL OF RADIOLOGY, 1995, 21 (01) : 25 - 33
  • [40] MR cisternography for trigeminal neuralgia: comparison between gradient-echo and spin echo 3D sequences
    Wamasing, Natnicha
    Watanabe, Hiroshi
    Kuribayashi, Ami
    Imaizumi, Akiko
    Sakamoto, Junichiro
    Tomisato, Hiroshi
    DENTOMAXILLOFACIAL RADIOLOGY, 2025,