Intraoperative Measurement of Tibial Rotation With Lateral Axis Views Using C-arm for Tibial Fractures

被引:1
|
作者
Kinami, Yo [1 ]
Yamamoto, Norio [2 ]
Fujiwara, Kazuo [1 ]
机构
[1] Okayama City Hosp, Dept Orthoped Surg, Okayama, Japan
[2] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Dept Epidemiol, Okayama, Japan
关键词
comminuted fracture; segmental fracture; incidence of malrotation; bimalleolar axis; tibial posterior; condylar axis; tibial external rotation; tibial malrotation; c-arm; MALROTATION; MALALIGNMENT; TORSION; PREVALENCE; DEFORMITY; MALUNION;
D O I
10.7759/cureus.47091
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Malrotation of tibial fractures after intramedullary nailing remains an unsolved problem. The incidence of malrotation >10(degrees) on computer tomography (CT) measurements has been high in cases of tibial shaft fractures. We aimed to assess the accuracy of a novel method for the measurement of tibial rotation using lateral axis views of the C-arm, to prevent postoperative malrotation. Consecutive patients with fresh tibial fractures treated by intramedullary nailing between January 2021 and December 2022 were included prospectively. Baseline tibial external rotation (TER) was measured preoperatively on the non-injured normal side with CT. After proximal or distal screw fixation, the C-arm TER was measured based on lateral axis views (tibial posterior condylar axis and bimalleolar axis views). The C-arm TER was compared with the normal-side CT TER; when the difference was <= 5(degrees), the procedure progressed, and screw fixation was carried out. The fractured-side CT TER was measured one week post-operatively. Twenty patients (13 males and seven females) were included. The mean age was 52.4 years. The Orthopaedic Trauma Association (OTA) classification was 42A in five patients, 42B in twelve patients, and 42C in three patients. The mean difference between C-arm TER and fractured-side CT TER was 2.3(degrees)+/- 1.7(degrees), with Pearson correlation coefficient r=0.968. The mean difference between normal-side CT TER and fractured-side CT TER was 4.8(degrees)+/- 2.8(degrees), and there was no incidence of malrotation >10(degrees). The C-arm method was highly accurate in estimating CT measurements and preventing tibial malrotation.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Minimally invasive reconstruction of lateral tibial plateau fractures using the jail technique: a biomechanical study
    Weimann, Andre
    Heinkele, Thomas
    Herbort, Mirco
    Schliemann, Benedikt
    Petersen, Wolf
    Raschke, Michael J.
    BMC MUSCULOSKELETAL DISORDERS, 2013, 14
  • [32] Development of an intraoperative 3D C-arm technique for torsion control of femur fractures: a cadaver study
    T. Stubig
    H. Aidarous
    A. Khalifa
    M. Omar
    C. Krettek
    T. Omar Pacha
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 1739 - 1743
  • [33] Thoracic pedicle screw insertion in scoliosis using posteroanterior C-arm rotation method
    Lee, Choon-Sung
    Kim, Michael J.
    Ahn, Young-Joon
    Kim, Yung-Tae
    Jeong, Kyeong-Il
    Lee, Dong-Ho
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (01): : 66 - 71
  • [34] Brachytherapy seed reconstruction with joint-encoded C-arm single-axis rotation and motion compensation
    Dehghan, Ehsan
    Jain, Ameet K.
    Moradi, Mehdi
    Wen, Xu
    Morris, W. James
    Salcudean, Septimiu E.
    Gichtinger, Gabor
    MEDICAL IMAGE ANALYSIS, 2011, 15 (05) : 760 - 771
  • [35] Closed reduction of mandibular condyle fractures using C-arm fluoroscopy: a technical note
    Imai, Tomoaki
    Michizawa, Masahiro
    Yamamoto, Naofumi
    Kai, Tatsuro
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 115 (01): : E4 - E9
  • [36] Using the anatomical tibial axis for total knee arthroplasty alignment may lead to an internal rotation error
    Csaba Forster-Horvath
    Valerie Kremo
    Magdalena Müller-Gerbl
    Andrej Maria Nowakowski
    International Orthopaedics, 2015, 39 : 2347 - 2353
  • [37] Using the anatomical tibial axis for total knee arthroplasty alignment may lead to an internal rotation error
    Forster-Horvath, Csaba
    Kremo, Valerie
    Mueller-Gerbl, Magdalena
    Nowakowski, Andrej Maria
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (12) : 2347 - 2353
  • [38] Intraoperative measurement of cup inclination using fluoroscopy: do we need a different correction factor when using a different C-arm model
    Sterneder, Christian Manuel
    Springer, Bernhard
    Haralambiev, Lyubomir
    Boettner, Friedrich
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2025, 145 (01)
  • [39] Preoperative and Intraoperative Considerations Using Intramedullary Nails for the Treatment of Tibial Shaft Fractures Below Total Knee Arthroplasty
    Stevens, Nicole M.
    Tyler, Andrew F.
    Mitchell, Phillip M.
    Stinner, Daniel J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2022, 36 (11) : E437 - E441
  • [40] Intraoperative torsion control using the cortical step sign and diameter difference in tibial mid-shaft fractures
    Keppler, Alexander M.
    Kuessner, Konstantin
    Suero, Eduardo M.
    Kronseder, Veronika
    Boecker, Wolfgang
    Kammerlander, Christian
    Zeckey, Christian
    Neuerburg, C.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (05) : 3659 - 3667