Overcoming the obstacle of excess acetonitrile content in the final fluorine-18 radiotracers

被引:0
|
作者
Al-Qahtani, Mohammed [1 ]
机构
[1] King Faisal Specialist Hosp & Res Ctr, Cyclotron & Radiopharmaceut Dept, Riyadh, Saudi Arabia
关键词
fluorine-18; acetonitrile content; PET; cut-off injection time; EMISSION-TOMOGRAPHY RADIOPHARMACEUTICALS; QUALITY-CONTROL; RESIDUAL SOLVENTS; IMPURITIES; PHARMACEUTICALS; CHALLENGES;
D O I
10.1515/ract-2023-0225
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Acetonitrile is widely used as a solvent in synthesizing various fluorine-18 positron emission tomography (PET) radiotracers. Acetonitrile is classified as a Class II residual solvent, and due to its inherent toxic properties, the quantity of residual acetonitrile in drug products has to be limited. When working under Good Manufacturing Practices (GMP) during the radiosynthesis of a radiotracer, the aim is to control all solvent concentrations contained in the ready-to-use product. All products must meet predetermined specifications. Rarely, these limits may be exceeded. To avoid eliminating the entire batch, applying a straightforward time-based technique would be desirable to allow the majority of the product to be safely used. This technique should be based on determining a specific time and volume for which the radiotracer can be utilized in the patients after completing quality control analysis. Here, we report a very simple Excel sheet program based on existing mathematical equations that calculates the exact time and volume at which the radiotracer product can be safely administered to a patient.
引用
收藏
页码:111 / 116
页数:6
相关论文
共 34 条
  • [31] Radiation dose to technicians per nuclear medicine procedure: comparison between technetium-99m, gallium-67, and iodine-131 radiotracers and fluorine-18 fluorodeoxyglucose
    Chiesa, C
    DeSanctis, V
    Crippa, F
    Schiavini, M
    Fraigola, CE
    Bogni, A
    Pascali, C
    Decise, D
    Marchesini, R
    Bombardieri, E
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (11) : 1380 - 1389
  • [32] Radiation dose to technicians per nuclear medicine procedure: comparison between technetium-99m, gallium-67, and iodine-131 radiotracers and fluorine-18 fluorodeoxyglucose
    C. Chiesa
    V. De Sanctis
    F. Crippa
    M. Schiavini
    C. E. Fraigola
    A. Bogni
    C. Pascali
    D. Decise
    R. Marchesini
    E. Bombardieri
    European Journal of Nuclear Medicine, 1997, 24 : 1380 - 1389
  • [33] Synthesis and invivo Evaluation of Fluorine-18 and Iodine-123 Pyrazolo[4,3-e]-1,2,4-triazolo[1,5-c]pyrimidine Derivatives as PET and SPECT Radiotracers for Mapping A2A Receptors
    Vala, Christine
    Morley, Thomas J.
    Zhang, Xuechun
    Papin, Caroline
    Tavares, Adriana Alexandre S.
    Lee, H. Sharon
    Constantinescu, Cristian
    Barret, Olivier
    Carroll, Vincent M.
    Baldwin, Ronald M.
    Tamagnan, Gilles D.
    Alagille, David
    CHEMMEDCHEM, 2016, 11 (17) : 1936 - 1943
  • [34] RADIOTRACERS IN FLUORINE CHEMISTRY .14. THE LABILITY OF THE FLUOROANIONS BF4-, PF6-, ASF6-, SBF6-, NBF6- AND TAF6- IN ACETONITRILE SOLUTION - A F-18 RADIOTRACER STUDY [1,2]
    GHORAB, MF
    WINFIELD, JM
    JOURNAL OF FLUORINE CHEMISTRY, 1990, 49 (03) : 367 - 383