Contour-guided deep learning based deformable image registration for dose monitoring during CBCT-guided radiotherapy of prostate cancer

被引:5
|
作者
Hemon, Cedric [1 ]
Rigaud, Bastien [1 ]
Barateau, Anais [1 ]
Tilquin, Florian [1 ]
Noblet, Vincent [2 ]
Sarrut, David [3 ]
Meyer, Philippe [4 ]
Bert, Julien [5 ]
De Crevoisier, Renaud [1 ]
Simon, Antoine [1 ]
机构
[1] Univ Rennes, CLCC Eugene Marquis, INSERM, LTSI UMR 1099, Campus Beaulieu, F-35042 Rennes, France
[2] ICube UMR 7357, Lab Sci Ingn Informat & Imagerie, Illkirch Graffenstaden, France
[3] Univ Lyon 1, Univ Lyon, CREATIS, CNRS UMR5220,Inserm U1294,INSA Lyon, Lyon, France
[4] Paul Strauss Ctr, Dept Med Phys, Strasbourg, France
[5] Univ Brest, Fac Med, LaTIM, INSERM UMR 1101,IBRBS, Brest, France
来源
关键词
CBCT; deformable registration; dose monitoring; prostate; RADIATION-THERAPY; SEGMENTATION; TRACKING; TRIAL; CT;
D O I
10.1002/acm2.13991
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo evaluate deep learning (DL)-based deformable image registration (DIR) for dose accumulation during radiotherapy of prostate cancer patients. Methods and MaterialsData including 341 CBCTs (209 daily, 132 weekly) and 23 planning CTs from 23 patients was retrospectively analyzed. Anatomical deformation during treatment was estimated using free-form deformation (FFD) method from Elastix and DL-based VoxelMorph approaches. The VoxelMorph method was investigated using anatomical scans (VMorph_Sc) or label images (VMorph_Msk), or the combination of both (VMorph_Sc_Msk). Accumulated doses were compared with the planning dose. ResultsThe DSC ranges, averaged for prostate, rectum and bladder, were 0.60-0.71, 0.67-0.79, 0.93-0.98, and 0.89-0.96 for the FFD, VMorph_Sc, VMorph_Msk, and VMorph_Sc_Msk methods, respectively. When including both anatomical and label images, VoxelMorph estimated more complex deformations resulting in heterogeneous determinant of Jacobian and higher percentage of deformation vector field (DVF) folding (up to a mean value of 1.90% in the prostate). Large differences were observed between DL-based methods regarding estimation of the accumulated dose, showing systematic overdosage and underdosage of the bladder and rectum, respectively. The difference between planned mean dose and accumulated mean dose with VMorph_Sc_Msk reached a median value of +6.3 Gy for the bladder and -5.1 Gy for the rectum. ConclusionThe estimation of the deformations using DL-based approach is feasible for male pelvic anatomy but requires the inclusion of anatomical contours to improve organ correspondence. High variability in the estimation of the accumulated dose depending on the deformable strategy suggests further investigation of DL-based techniques before clinical deployment.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Quantitative Analysis of the Accuracy of CT to CBCT Deformable Image Registration for Contour Mapping for Prostate Cancer
    Schmidt, R.
    Dogan, N.
    Ford, J.
    Studenski, M.
    Abramowitz, M.
    Padgett, K.
    Spieler, B.
    Xu, Y.
    Delgadillo, R.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [32] Deep-learning-based joint rigid and deformable contour propagation for magnetic resonance imaging-guided prostate radiotherapy
    Kolenbrander, Iris D.
    Maspero, Matteo
    Hendriksen, Allard A.
    Pollitt, Ryan
    van der Voort van Zyp, Jochem R. N.
    van den Berg, Cornelis A. T.
    Pluim, Josien P. W.
    van Eijnatten, Maureen A. J. M.
    MEDICAL PHYSICS, 2024, 51 (04) : 2367 - 2377
  • [33] A Study of the Optimal PTV Margin for Patients Receiving CBCT-Guided Prostate IMRT Based On CBCT Dose Calculation
    Gill, S.
    Pearson, D.
    Dalhart, A.
    Reddy, K.
    Chen, C.
    MEDICAL PHYSICS, 2014, 41 (06) : 227 - 227
  • [34] A Fast Deformable Model Based 3D Registration Algorithm for Image Guided Prostate Radiotherapy
    Zhou, J.
    Kim, S.
    Jabbour, S.
    Goyal, S.
    Haffty, B.
    Chen, T.
    Chang, S.
    Metaxas, D.
    Yue, N.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [35] Deep learning-based projection synthesis for low-dose CBCT imaging in image-guided radiotherapy
    Zhao, Xuzhi
    Du, Yi
    Yue, Haizhen
    Wang, Ruoxi
    Zhou, Shun
    Wu, Hao
    Wang, Wei
    Peng, Yahui
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (01) : 231 - 250
  • [36] Assessment of Dose Accumulation with Different Deformable Image Registration Algorithms for Image-Guided Radiotherapy of Head and Neck Cancer
    Dogan, N.
    Sleeman, W.
    Asher, D.
    Fatyga, M.
    Schutzer, M.
    Song, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [37] Image Guided Radiotherapy of the Cervix with Biomechanical Model-Based Deformable Registration
    Brock, K.
    Moseley, J.
    Stewart, J.
    Lim, K.
    Xie, J.
    Lundin, A.
    Rehbinder, H.
    Fyles, A.
    Milosevic, M.
    Jaffray, D.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [38] HYBRID REGISTRATION TECHNIQUE FOR IMAGE-GUIDED RADIOTHERAPY OF PROSTATE CANCER
    de Boer, J.
    van Herk, M.
    de Bois, J.
    Sonke, J. J.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S173 - S174
  • [39] Deformable image registration for cone-beam CT (CBCT) images for implemantion of image-guided adaptive radiotherapy
    Zhang, L.
    Dong, L.
    Ahamad, A.
    Zhu, X. R.
    Garden, A. S.
    Ang, K. K.
    Mohan, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S647 - S648
  • [40] Seminal Vesicle Interfraction Displacement and Dose Variations Throughout the CBCT-Guided Radiation Therapy for Prostate Cancer
    Oksuz, D. C.
    Dincbas, F. O.
    Ergen, S. A.
    Iktueren, B.
    Bakir, A.
    Koca, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S429 - S430